EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Comparison of Periprosthetic Femoral Bone Remodeling After Total Hip Arthroplasty with Zimmer VerSys Taper Stem or VerSys Midcoat Stem: Long-Term Outcomes

Keishi Kimura, Norio Imai iD, Yuki Hirano, Yoji Horigome, Hiroyuki Kawashima

Journal of Clinical Medicine · 02.07.2026 · 15 (13) · 5181

DOI: 10.3390/jcm15135181 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 02.07.2026. Verfasst von Keishi Kimura und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Regenerative and Transplant Medicine, Division of Orthopedic Surgery, Niigata University Graduate School of Medicine, Dentistry and Hea…. Die Arbeit nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Objectives: We compared long-term radiological femoral bone remodeling after total hip arthroplasty (THA) with either the VerSys Taper stem (T) or VerSys Midcoat stem (M).

Methods

Of 206 patients who underwent unilateral primary THA, 157 (T group: 65; M group: 92) were followed up for >15 years. Stress shielding was evaluated according to Engh’s classification, cancellous condensation and cortical hypertrophy in each zone were assessed according to Gruen’s zone, and fixation was evaluated using Engh’s classification. We investigated the grade of each stem at each point in stress shielding.

Results

Grade 3 or 4 stress shielding incidence was higher in the T group than in the M group, and stress shielding grades at each time point were significantly higher in the T group. The stress shielding grade showed progressively greater divergence in the T group, consistent with a significant stem × time interaction. The generalized linear mixed model showed significant zonal variation in cancellous condensation but no effects of stem type or stem × zone interaction. Similarly, cortical hypertrophy showed no significant effects of stem type, zone, or their interaction. There were no cases of unstable fixation in either group; however, 90.2% of patients in the M group had bone ingrowth, whereas 23.1% of patients in the T group had fibrous stability. There were no cases of revision owing to aseptic loosening in either group.

Conclusions

These findings suggest that the primary long-term difference between the stem designs lies in the trajectory of stress-shielding progression rather than in zonal bone responses.

Schlagwörter

Stichwörter der Autor:innen

bone remodelingcortical hypertrophystress shieldingtotal hip arthroplasty

Autor:innen und Institutionen

  • Department of Regenerative and Transplant Medicine, Division of Orthopedic Surgery, Niigata University Graduate School of Medicine, Dentistry and Health Sciences, Niigata 951-8510, Japan.
  • Division of Comprehensive Musculoskeletal Medicine, Niigata University Graduate School of Medicine, Dentistry and Health Sciences, Niigata 951-8510, Japan.

ORCID-Profile: Norio Imai

Zitieren

APA

Kimura, K., Imai, N., Hirano, Y., Horigome, Y., & Kawashima, H. (2026). Comparison of Periprosthetic Femoral Bone Remodeling After Total Hip Arthroplasty with Zimmer VerSys Taper Stem or VerSys Midcoat Stem: Long-Term Outcomes. Journal of Clinical Medicine, 15(13), 5181. https://doi.org/10.3390/jcm15135181

Vancouver

Kimura K, Imai N, Hirano Y, Horigome Y, Kawashima H. Comparison of Periprosthetic Femoral Bone Remodeling After Total Hip Arthroplasty with Zimmer VerSys Taper Stem or VerSys Midcoat Stem: Long-Term Outcomes. Journal of Clinical Medicine. 2026;15(13):5181. doi:10.3390/jcm15135181

BibTeX
@article{Kimura2026,
  author = {Kimura, Keishi and Imai, Norio and Hirano, Yuki and Horigome, Yoji and Kawashima, Hiroyuki},
  title = {Comparison of Periprosthetic Femoral Bone Remodeling After Total Hip Arthroplasty with Zimmer VerSys Taper Stem or VerSys Midcoat Stem: Long-Term Outcomes},
  journal = {Journal of Clinical Medicine},
  year = {2026},
  volume = {15},
  number = {13},
  pages = {5181},
  doi = {10.3390/jcm15135181}
}
Kostenlos starten →