The Importance of Instrumentation Length in Ankylosing Spinal Disorders and Thoracolumbar Fractures
Journal of Clinical Medicine · 30.06.2026 · 15 (13) · 5082
DOI: 10.3390/jcm15135082 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 30.06.2026. Verfasst von Federico Fusini und 7 weiteren Autor:innen. Beteiligte Einrichtung: Spine Surgery Unit, Orthopaedic and Trauma Centre, Città della Salute e della Scienza di Torino, 10126 Turin, Italy. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background/Objectives: Ankylosing Spinal Disorders (ASDs) encompass a heterogeneous group of rheumatic diseases characterized by progressive ankylosis of the axial skeleton, including Ankylosing Spondylitis (AS), Diffuse Idiopathic Skeletal Hyperostosis (DISH), and Non-Radiographic Axial Spondyloarthritis (nr-AxSpA). Spinal ankylosis profoundly alters the biomechanical properties of the vertebral column, transforming it into a rigid long-bone equivalent and dramatically increasing fracture risk even after low-energy trauma. Once a fracture occurs, the long lever arm created by the ankylosed segments generates enormous mechanical stress at the fracture site, making surgical stabilization mandatory in the vast majority of cases. Long posterior instrumentation is the treatment of choice; however, no consensus exists regarding the optimal number of instrumented levels. The aim of this study is to clinically and radiologically evaluate long posterior instrumentation in the 3 + 3 (3 proximal and 3 caudal screws), 3 + 2 (3 proximal and 2 caudal screws), or 2 + 2 (2 proximal and 2 caudal screws) configuration for the treatment of traumatic ASD thoracolumbar vertebral fractures, in terms of implant failure, infection rate, and mortality.
Methods
Between 2018 and 2023, 65 consecutive patients with ASD-related thoracolumbar vertebral fractures were treated at our institution. After applying pre-defined inclusion and exclusion criteria, 37 patients were enrolled. Patients were retrospectively divided into three groups according to the posterior arthrodesis configuration (notation indicates number of instrumented vertebral levels proximal + distal to the fracture: 3 + 3, 3 + 2, or 2 + 2). Radiological outcomes were assessed for loosening, screw cut-out, and implant breakage. Infection and mortality rates within 3 months from surgery were evaluated as secondary endpoints. Statistical analysis was performed using the Fisher exact test (significance set at p < 0.05).
Results
Thirty-seven patients (28 males and 9 females; mean age 77 ± 7.3 years) were included, with a mean follow-up of 30 ± 5.3 months. Instrumentation configurations were as follows: 23 (3 + 3), 5 (3 + 2), and 9 (2 + 2). Three implant failures (8.1%) and four infections (10.8%) were recorded. Eleven patients died within 3 months of surgery. A statistically significant difference was found between instrumentation length and mechanical complications (p = 0.0468), while no significant difference was observed for infection (p = 1) or mortality rate (p = 0.137).
Conclusions
In this exploratory retrospective cohort, the 3 + 3 configuration was associated with the lowest observed rate of implant failure in ASD thoracolumbar fractures, suggesting a potential mechanical advantage over shorter constructs that warrants confirmation in larger prospective studies. No significant correlation was found between instrumentation length and infection rate or early mortality. Prospective, multicentre studies with larger cohorts are warranted to establish definitive guidelines for instrumentation length in this challenging patient population.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Spine Surgery Unit, Orthopaedic and Trauma Centre, Città della Salute e della Scienza di Torino, 10126 Turin, Italy.
- Circolo Hospital, Macchi Foundation, Insubria University, Viale Borri 57, 21100 Varese, Italy.
ORCID-Profile: Federico Fusini, Gabriele Colò
Zitieren
APA
Fusini, F., Rava, A., Gargiulo, G., Messina, D., Lorenzi, A., Amico, S., Colò, G., & Girardo, M. (2026). The Importance of Instrumentation Length in Ankylosing Spinal Disorders and Thoracolumbar Fractures. Journal of Clinical Medicine, 15(13), 5082. https://doi.org/10.3390/jcm15135082
Vancouver
Fusini F, Rava A, Gargiulo G, Messina D, Lorenzi A, Amico S, et al. The Importance of Instrumentation Length in Ankylosing Spinal Disorders and Thoracolumbar Fractures. Journal of Clinical Medicine. 2026;15(13):5082. doi:10.3390/jcm15135082
BibTeX
@article{Fusini2026,
author = {Fusini, Federico and Rava, Alessandro and Gargiulo, Giosuè and Messina, Domenico and Lorenzi, Alberto and Amico, Silvia and Colò, Gabriele and Girardo, Massimo},
title = {The Importance of Instrumentation Length in Ankylosing Spinal Disorders and Thoracolumbar Fractures},
journal = {Journal of Clinical Medicine},
year = {2026},
volume = {15},
number = {13},
pages = {5082},
doi = {10.3390/jcm15135082}
}
EUVIMED