Dynamic Voice Optimization After Type I Thyroplasty Using a Novel Adjustable Implant: A Prospective Longitudinal Study
Journal of Clinical Medicine · 25.06.2026 · 15 (13) · 4927
DOI: 10.3390/jcm15134927 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 25.06.2026. Verfasst von Nadhirah Mohd Shakri und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otorhinolaryngology-Head and Neck Surgery, Faculty of Medicine, Universiti Kebangsaan Malaysia, Bandar Tun Razak, Kuala Lumpur 56000, M…. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: MED-EL electronic Sdn Bhd Malaysia, MED-EL Electronics Sdn Bhd.
Abstract (Originalsprache)
Objective
To evaluate the clinical outcome, safety and efficacy of the APrevent Vocal Implant System (VOIS) in patients with unilateral vocal fold paralysis (UVFP), with particular emphasis on the timing and impact of postoperative saline adjustments.
Methods
This retrospective−prospective longitudinal study included 11 patients with chronic UVFP who underwent VOIS medialization thyroplasty (MT) under local anesthesia (n = 2) and general anesthesia (n = 9). Multidimensional voice parameters were analyzed preoperatively and at 1, 3, 6, and 12 months postoperatively. Statistical analyses included the Friedman test for repeated measures and the comparison of outcomes between pre- and each postoperative timepoints was evaluated with the Wilcoxon signed-rank test.
Results
Significant and sustained improvements were observed across all multidimensional voice parameters. Mean mVHI-10 decreased from 31.7 ± 4.5 preoperatively to 5.8 ± 5.1 at 12 months, while mean MPT increased from 7.1 ± 3.8 to 14.4 ± 4.5 s (p < 0.05, r > 0.7). Acoustic parameters, including jitter, shimmer, and NHR, demonstrated progressive improvement over 12 months. A high proportion of patients (72.73%) underwent postoperative saline adjustment at a mean interval of 6.23 ± 1.23 months, beyond the early postoperative edema phase, with each adjustment yielding further enhancement in voice outcomes. No major complications, including airway obstruction or hematoma, were observed.
Conclusions
VOIS MT is safe and effective, providing sustained improvements in multidimensional voice outcomes. The ability to perform postoperative saline adjustments enables dynamic optimization of glottal closure, reducing the need for revision surgery and addressing evolving laryngeal biomechanics. These findings support VOIS as a flexible, adjustable alternative to static medialization techniques and provide dynamic voice optimization in patients with UVFP.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Otorhinolaryngology-Head and Neck Surgery, Faculty of Medicine, Universiti Kebangsaan Malaysia, Bandar Tun Razak, Kuala Lumpur 56000, Malaysia.
- Hospital Canselor Tuanku Muhriz, Universiti Kebangsaan Malaysia, Bandar Tun Razak, Kuala Lumpur 56000, Malaysia.
- Department of Otorhinolaryngology and Phoniatrics-Head and Neck Surgery, Helsinki University Hospital and University of Helsinki, Kasarmikatu 11-13, 00130 Helsinki, Finland.
ORCID-Profile: Qi Shen Chua, Ahmed Geneid, Marina Mat Baki
Förderung
- MED-EL electronic Sdn Bhd Malaysia
- MED-EL Electronics Sdn Bhd
Zitieren
APA
Mohd Shakri, N., Azman, M., Chua, Q. S., Geneid, A., & Mat Baki, M. (2026). Dynamic Voice Optimization After Type I Thyroplasty Using a Novel Adjustable Implant: A Prospective Longitudinal Study. Journal of Clinical Medicine, 15(13), 4927. https://doi.org/10.3390/jcm15134927
Vancouver
Mohd Shakri N, Azman M, Chua QS, Geneid A, Mat Baki M. Dynamic Voice Optimization After Type I Thyroplasty Using a Novel Adjustable Implant: A Prospective Longitudinal Study. Journal of Clinical Medicine. 2026;15(13):4927. doi:10.3390/jcm15134927
BibTeX
@article{MohdShakri2026,
author = {Mohd Shakri, Nadhirah and Azman, Mawaddah and Chua, Qi Shen and Geneid, Ahmed and Mat Baki, Marina},
title = {Dynamic Voice Optimization After Type I Thyroplasty Using a Novel Adjustable Implant: A Prospective Longitudinal Study},
journal = {Journal of Clinical Medicine},
year = {2026},
volume = {15},
number = {13},
pages = {4927},
doi = {10.3390/jcm15134927}
}
EUVIMED