Comparative Diagnostic Performance of Metabolic Scoring Indices for Ultrasonographic Hepatic Steatosis: Development and Validation of a Novel Composite Score in 1204 Consecutive Patients
Journal of Clinical Medicine · 04.06.2026 · 15 (11) · 4366
DOI: 10.3390/jcm15114366 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 04.06.2026. Verfasst von Gülşah Altun und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Internal Medicine, Sivas Numune Hospital, 58100 Sivas, Turkey. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background/Objectives: Metabolic dysfunction-associated steatotic liver disease (MASLD), formerly termed non-alcoholic fatty liver disease (NAFLD), is the most prevalent chronic liver condition globally, affecting one-quarter of the adult population. Non-invasive metabolic indices offer a pragmatic alternative to liver biopsy for population-level steatosis screening. We aimed to systematically compare the diagnostic performance of four widely used metabolic indices—TyG, LAP, FLI, and VAI—and to derive a novel composite score that demonstrably surpasses each constituent index.
Methods
Retrospective cross-sectional study; 1204 consecutive adults undergoing abdominal ultrasonography at a single tertiary centre (study period: 2024–2025; data collection period: January–April 2026); steatosis graded 0–3 by certified radiologists; four metabolic indices retrieved from pre-calculated columns; novel composite score derived by binary logistic regression with 10-fold stratified cross-validation (stratified by binary outcome); AUROC with 1000-iteration bootstrap 95% CI; and pairwise comparisons by the DeLong method.
Results
Of 1204 patients (mean age 42.3 ± 12.5 years; 73.3% male; 13.4% with diabetes), steatosis grades were: Grade 0, 185 (15.4%); Grade 1, 539 (44.8%); Grade 2, 311 (25.8%); and Grade 3, 169 (14.0%). For significant steatosis (Grade ≥ 2), TyG achieved AUROC 0.884 [0.863–0.904] and LAP 0.883 [0.862–0.901], while FLI showed only moderate performance. The novel composite score achieved AUROC 0.896 [0.870–0.920] for any steatosis and 0.922 [0.906–0.938] for significant steatosis, significantly outperforming all four individual indices (DeLong p = 0.004 vs. TyG; p = 0.002 vs. LAP; p < 0.001 vs. FLI; p < 0.001 vs. VAI). Youden-optimal performance: sensitivity 87.1%, specificity 86.0%, and Youden index 0.731.
Conclusions
A 10-fold cross-validated logistic composite of four metabolic indices significantly outperforms each constituent index for ultrasonographic hepatic steatosis detection. The composite score may serve as a practical, non-invasive tool for steatosis risk stratification pending external validation.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Internal Medicine, Sivas Numune Hospital, 58100 Sivas, Turkey.
- Department of Endocrinology and Metabolism, Sivas Numune Hospital, 58100 Sivas, Turkey.
Zitieren
APA
Altun, G., & Çiftel, E. (2026). Comparative Diagnostic Performance of Metabolic Scoring Indices for Ultrasonographic Hepatic Steatosis: Development and Validation of a Novel Composite Score in 1204 Consecutive Patients. Journal of Clinical Medicine, 15(11), 4366. https://doi.org/10.3390/jcm15114366
Vancouver
Altun G, Çiftel E. Comparative Diagnostic Performance of Metabolic Scoring Indices for Ultrasonographic Hepatic Steatosis: Development and Validation of a Novel Composite Score in 1204 Consecutive Patients. Journal of Clinical Medicine. 2026;15(11):4366. doi:10.3390/jcm15114366
BibTeX
@article{Altun2026,
author = {Altun, Gülşah and Çiftel, Enver},
title = {Comparative Diagnostic Performance of Metabolic Scoring Indices for Ultrasonographic Hepatic Steatosis: Development and Validation of a Novel Composite Score in 1204 Consecutive Patients},
journal = {Journal of Clinical Medicine},
year = {2026},
volume = {15},
number = {11},
pages = {4366},
doi = {10.3390/jcm15114366}
}
EUVIMED