EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A New Method for Measuring Structural Limb-Length Discrepancy: A Quasi-Experimental Study

Huthaifa Atallah iD, Titeana Qufabz iD, Mahmoud Alfatafta iD, Amneh Alshawabka iD, Mohamad Samih Yasin, Omar Q Samarah, Anthony McGarry iD, Bálint Molics iD

Journal of Clinical Medicine · 02.06.2026 · 15 (11) · 4309

DOI: 10.3390/jcm15114309 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 02.06.2026. Verfasst von Huthaifa Atallah und 7 weiteren Autor:innen. Beteiligte Einrichtung: Prosthetics and Orthotics Department, School of Rehabilitation Sciences, The University of Jordan, Amman 11942, Jordan. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Jordan.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Objectives: Limb-length discrepancy (LLD) is a relatively common condition, with structural LLD characterized by true shortening of a bony structure. Although various clinical and radiological methods are available, none rely exclusively on position of malleoli relative to one another. This study aims to introduce a novel method for measuring structural LLD using malleoli in conjunction with a ruler. A quasi-experimental study.

Methods

Eighteen participants with structural LLD were recruited from an orthopaedic clinic. Each participant underwent four tests: Paired Medial Malleolus Level Test (PMMLT) (new method), measuring tape method (Anterior Superior Iliac Spine (ASIS) to Medial Malleoli (MM), standing-block test, and full-length standing (long bone) radiography. Validity was assessed against radiography.

Results

The mean ± SD LLD measured by radiography was 2.99 ± 1.69 cm. Corresponding values were obtained with the PMMLT (2.98 ± 1.69 cm), measuring tape method (2.95 ± 1.66 cm), and the standing-block test (2.92 ± 1.73 cm). No significant differences were found among the methods (χ2(3) = 3.43, p = 0.330). Correlations with radiography were very strong (PMMLT r = 0.996; measuring tape method r = 0.990; standing-block test r = 0.991; all p < 0.001). PMMLT showed negligible bias (−0.01 cm), the narrowest 95% limits of agreement (−0.32 to 0.30 cm), and the lowest RMSE (0.15 cm).

Conclusions

The PMMLT demonstrates accuracy and practicality while being simple, cost-effective, and free of radiation exposure, making it a valuable alternative for clinical assessment of LLD in settings where imaging is unavailable or contraindicated.

Schlagwörter

Stichwörter der Autor:innen

clinical measurementlimb-length discrepancymalleolusradiography

Autor:innen und Institutionen

  • Prosthetics and Orthotics Department, School of Rehabilitation Sciences, The University of Jordan, Amman 11942, Jordan.
  • Division of Orthopaedics, Department of Special Surgery, School of Medicine, The University of Jordan, Amman 11942, Jordan.
  • Biomedical Engineering Department, University of Strathclyde, Glasgow G4 0NW, UK.
  • Department of Sport Physiotherapy, Faculty of Health Sciences, University of Pécs, 7621 Pécs, Hungary.

ORCID-Profile: Huthaifa Atallah, Titeana Qufabz, Mahmoud Alfatafta, Amneh Alshawabka, Anthony McGarry, Bálint Molics

Förderung

  • University of Jordan

Zitieren

APA

Atallah, H., Qufabz, T., Alfatafta, M., Alshawabka, A., Yasin, M. S., Samarah, O. Q., McGarry, A., & Molics, B. (2026). A New Method for Measuring Structural Limb-Length Discrepancy: A Quasi-Experimental Study. Journal of Clinical Medicine, 15(11), 4309. https://doi.org/10.3390/jcm15114309

Vancouver

Atallah H, Qufabz T, Alfatafta M, Alshawabka A, Yasin MS, Samarah OQ, et al. A New Method for Measuring Structural Limb-Length Discrepancy: A Quasi-Experimental Study. Journal of Clinical Medicine. 2026;15(11):4309. doi:10.3390/jcm15114309

BibTeX
@article{Atallah2026,
  author = {Atallah, Huthaifa and Qufabz, Titeana and Alfatafta, Mahmoud and Alshawabka, Amneh and Yasin, Mohamad Samih and Samarah, Omar Q and McGarry, Anthony and Molics, Bálint},
  title = {A New Method for Measuring Structural Limb-Length Discrepancy: A Quasi-Experimental Study},
  journal = {Journal of Clinical Medicine},
  year = {2026},
  volume = {15},
  number = {11},
  pages = {4309},
  doi = {10.3390/jcm15114309}
}
Kostenlos starten →