Real-Time Ultrasound Elastography in Multiple Sclerosis Spasticity: Comparison with Clinical and Neurophysiological Measures
Journal of Clinical Medicine · 26.05.2026 · 15 (11) · 4095
DOI: 10.3390/jcm15114095 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 26.05.2026. Verfasst von Eleni Bakola und 7 weiteren Autor:innen. Beteiligte Einrichtung: Second Department of Neurology, National and Kapodistrian University of Athens, School of Medicine, Attikon University Hospital, 12462 Athens, Greece. Die Arbeit nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Spasticity is a common and disabling symptom of multiple sclerosis (MS), yet its assessment remains challenging. Clinical scales such as the Ashworth Scale (AS) evaluate resistance to passive movement, whereas neurophysiological measures (e.g., H-reflex, F-wave) provide objective indices of α-motoneuron excitability but correlate inconsistently with clinical severity. Real-time ultrasound elastography (RTE) enables semi-quantitative, in vivo assessment of muscle stiffness, while the recently introduced Muscle Elastography Multiple Sclerosis Score (MEMSs) aims to classify muscle spasticity in MS.
Objective
To evaluate the utility of RTE using MEMSs for the objective assessment of muscle status in MS patients with spasticity, and to compare elastographic findings with clinical and neurophysiological measures.
Methods
In this single-center study, 26 MS patients (diagnosed according to the 2017 McDonald criteria) and age- and sex-matched healthy controls (n = 27) were enrolled. Spasticity was graded using the AS. All participants underwent bilateral RTE of the gastrocnemius muscle, with images independently scored by two blinded neurologists using the 5-point MEMSs scale. Neurophysiological assessment included the soleus H-reflex, with calculation of H/M ratios. Correlations were analyzed using Pearson’s coefficient, and inter-observer reliability was assessed.
Results
No consistent or statistically robust associations were found between clinical spasticity severity (AS scores) and either neurophysiological or elastographic parameters. Several MEMSs did not correlate reliably with AS grades, and neurophysiological measures showed limited discriminatory ability between MS patients and healthy controls. Correlations between neurophysiological and elastography parameters were weak to moderate (ρ ranging from −0.49 to 0.45). Inter-observer reliability of MEMSs scoring ranged from poor to moderate across the examined muscle groups, with Cohen’s κ values ranging from −0.02 to 0.54.
Conclusions
RTE using MEMSs did not demonstrate sufficient validity or reproducibility for assessing muscle spasticity in MS, showing poor agreement with both clinical and neurophysiological measures.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Second Department of Neurology, National and Kapodistrian University of Athens, School of Medicine, Attikon University Hospital, 12462 Athens, Greece.
- Department of Physiotherapy, University of West Attica, 12243 Athens, Greece.
ORCID-Profile: Eleni Bakola, Marianna Papadopoulou, Maria-Ioanna Stefanou, Athanasios K Chasiotis, Stella Fanouraki, Angeliki-Erato Sterpi, Dimitrios Kitsos, Georgios Tsivgoulis
Zitieren
APA
Bakola, E., Papadopoulou, M., Stefanou, M. I., Chasiotis, A. K., Fanouraki, S., Sterpi, A. E., Kitsos, D., & Tsivgoulis, G. (2026). Real-Time Ultrasound Elastography in Multiple Sclerosis Spasticity: Comparison with Clinical and Neurophysiological Measures. Journal of Clinical Medicine, 15(11), 4095. https://doi.org/10.3390/jcm15114095
Vancouver
Bakola E, Papadopoulou M, Stefanou MI, Chasiotis AK, Fanouraki S, Sterpi AE, et al. Real-Time Ultrasound Elastography in Multiple Sclerosis Spasticity: Comparison with Clinical and Neurophysiological Measures. Journal of Clinical Medicine. 2026;15(11):4095. doi:10.3390/jcm15114095
BibTeX
@article{Bakola2026,
author = {Bakola, Eleni and Papadopoulou, Marianna and Stefanou, Maria-Ioanna and Chasiotis, Athanasios K and Fanouraki, Stella and Sterpi, Angeliki-Erato and Kitsos, Dimitrios and Tsivgoulis, Georgios},
title = {Real-Time Ultrasound Elastography in Multiple Sclerosis Spasticity: Comparison with Clinical and Neurophysiological Measures},
journal = {Journal of Clinical Medicine},
year = {2026},
volume = {15},
number = {11},
pages = {4095},
doi = {10.3390/jcm15114095}
}
EUVIMED