Reliability of Macular Ganglion Cell-Inner Plexiform Layer Thickness Measurements Across Scan Protocols in Spectral-Domain Optical Coherence Tomography
Journal of Clinical Medicine · 22.05.2026 · 15 (11) · 3999
DOI: 10.3390/jcm15113999 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 22.05.2026. Verfasst von Nik Krajnc und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurology, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Austrian MS Research Society, Austrian Multiple Sclerosis Research Society.
Abstract (Originalsprache)
Objective
We aimed to assess whether modified OCT acquisition parameters improve GCIPL measurement reliability.
Methods
Participants with multiple sclerosis (PwMS) and age- and sex-matched healthy controls (HC) underwent OCT (Spectralis OCT, Heidelberg Engineering, Heidelberg, Germany) at baseline and after two and four weeks. At each visit, five macular scan protocols were acquired: standard (49 lines, high-speed [HS], automated real-time tracking [ART]: 9), high-ART (49 lines, HS, ART: 50), high-lines (97 lines, HS, ART: 9), high-resolution (49 lines, high-resolution [HR], ART: 9), and maximum (97 lines, HR, ART: 50). Reliability was assessed using intraclass correlation coefficients (ICC). Absolute test–retest reproducibility was quantified using the mean absolute difference (MAD).
Results
Thirty-eight eyes from nine PwMS (mean age 34.1 ± 8.0 years, 44.4% female) and ten HC (31.7 ± 11.1 years, 50.0% female) were included. At baseline, mean GCIPL thickness ranged from 70.8 µm to 71.5 µm across protocols, demonstrating excellent inter-protocol agreement (ICC 0.99; 95% confidence interval [CI]: 0.98–0.99; p < 0.001) and only marginally higher values with increased ART. Test–retest reliability was excellent for all protocols, demonstrating marginally lower absolute measurement variability of high-ART and high-lines protocols (MAD 0.26–0.27; 95% CI: 0.21–0.32), while temporal agreement remained excellent and comparable across acquisition settings. Mean acquisition time ranged from 10.6 ± 1.6 s for the standard protocol to 231.9 ± 36.4 s for the maximum protocol.
Conclusions
All OCT acquisition protocols demonstrated excellent inter-protocol and test–retest reliability for GCIPL measurements. The high-lines protocol provides the most favourable balance between measurement reliability and acquisition time, supporting its potential utility for longitudinal GCIPL monitoring.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Neurology, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria.
- Comprehensive Center for Clinical Neurosciences & Mental Health, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria.
- Department of Ophthalmology and Optometry, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria.
ORCID-Profile: Nik Krajnc, Martin Bertich, Berthold Pemp, Gabriel Bsteh
Förderung
- Austrian MS Research Society
- Austrian Multiple Sclerosis Research Society
Zitieren
APA
Krajnc, N., Bertich, M., Föttinger, F., Macher, S., Schwarz, F. K., Stapf, C., Pemp, B., & Bsteh, G. (2026). Reliability of Macular Ganglion Cell-Inner Plexiform Layer Thickness Measurements Across Scan Protocols in Spectral-Domain Optical Coherence Tomography. Journal of Clinical Medicine, 15(11), 3999. https://doi.org/10.3390/jcm15113999
Vancouver
Krajnc N, Bertich M, Föttinger F, Macher S, Schwarz FK, Stapf C, et al. Reliability of Macular Ganglion Cell-Inner Plexiform Layer Thickness Measurements Across Scan Protocols in Spectral-Domain Optical Coherence Tomography. Journal of Clinical Medicine. 2026;15(11):3999. doi:10.3390/jcm15113999
BibTeX
@article{Krajnc2026,
author = {Krajnc, Nik and Bertich, Martin and Föttinger, Fabian and Macher, Stefan and Schwarz, Felix Konstantin and Stapf, Christoph and Pemp, Berthold and Bsteh, Gabriel},
title = {Reliability of Macular Ganglion Cell-Inner Plexiform Layer Thickness Measurements Across Scan Protocols in Spectral-Domain Optical Coherence Tomography},
journal = {Journal of Clinical Medicine},
year = {2026},
volume = {15},
number = {11},
pages = {3999},
doi = {10.3390/jcm15113999}
}
EUVIMED