Evaluation of the Effectiveness and Color Stability of In-Office Bleaching Agents: A Retrospective Study
Journal of Clinical Medicine · 01.05.2026 · 15 (9) · 3458
DOI: 10.3390/jcm15093458 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 01.05.2026. Verfasst von İdil Gönüllü und 4 weiteren Autor:innen. Beteiligte Einrichtung: Restorative Department, Ege University, İzmir 35040, Turkey. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
The aim of this study was to evaluate the whitening efficacy and long-term stability of different in-office bleaching agents containing high concentrations of hydrogen peroxide (HP).
Methods
Records of 50 patients who underwent in-office bleaching treatment at the Department of Restorative Dentistry, Ege University, were retrospectively analyzed. Five bleaching agents were evaluated: Opalescence (40%HP), FGM Whiteness HP (35%HP), FGM Whiteness HP Blue (35%HP), Biowhiten (40%HP) and Powerbright (35%HP). Color measurements were obtained using a spectrophotometer (VITA Easyshade V, VITA Zahnfabrik, Bad Säckingen, Germany) and standardized intraoral photographs at baseline, immediately after treatment, at 1 week, 6 months, 12 months, and 18 months. Color change (ΔE00) was calculated using the CIEDE2000 formula, and shade differences were assessed using ΔSGU values. Statistical analyses were performed using repeated-measures ANOVA and Kruskal–Wallis tests, followed by post hoc comparisons where appropriate (p < 0.05).
Results
Baseline age distribution, initial color parameters, and patient-related behavioral factors were comparable among the groups, with no statistically significant differences observed. All bleaching agents resulted in significant color improvement at the 1-week evaluation (ΔE00 range: 3.67–6.34; p < 0.05), exceeding clinically acceptable thresholds. At 6 months, slight, non-significant reductions in ΔE00 values were observed in the Powerbright, FGM Whiteness HP Blue, and FGM Whiteness HP groups (p > 0.05). At 18 months, ΔE00 values remained within a clinically acceptable range (3.56–4.74), with no significant color regression in most groups (p > 0.05), except for a significant decrease in the FGM Whiteness HP group (p < 0.05).
Conclusions
High-concentration (35–40%) in-office bleaching agents demonstrated effective short-term whitening and maintained clinically acceptable and stable color outcomes over 18 months. Although material-dependent differences were observed, bleaching efficacy and long-term color stability appear to be influenced by multiple factors beyond hydrogen peroxide concentration alone. These findings support the clinical reliability of in-office bleaching procedures and highlight the importance of long-term follow-up.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Restorative Department, Ege University, İzmir 35040, Turkey.
ORCID-Profile: Hande Kemaloğlu
Zitieren
APA
Gönüllü, İ., Devrimci, E. E., Singün, B., Türkmen, E., & Kemaloğlu, H. (2026). Evaluation of the Effectiveness and Color Stability of In-Office Bleaching Agents: A Retrospective Study. Journal of Clinical Medicine, 15(9), 3458. https://doi.org/10.3390/jcm15093458
Vancouver
Gönüllü İ, Devrimci EE, Singün B, Türkmen E, Kemaloğlu H. Evaluation of the Effectiveness and Color Stability of In-Office Bleaching Agents: A Retrospective Study. Journal of Clinical Medicine. 2026;15(9):3458. doi:10.3390/jcm15093458
BibTeX
@article{Gnll2026,
author = {Gönüllü, İdil and Devrimci, Elif Ercan and Singün, Başak and Türkmen, Ege and Kemaloğlu, Hande},
title = {Evaluation of the Effectiveness and Color Stability of In-Office Bleaching Agents: A Retrospective Study},
journal = {Journal of Clinical Medicine},
year = {2026},
volume = {15},
number = {9},
pages = {3458},
doi = {10.3390/jcm15093458}
}
EUVIMED