Bleb Compressive Sutures in Descemet Stripping Automated Endothelial Keratoplasty for Eyes with Filtering Blebs Following Trabeculectomy
Journal of Clinical Medicine · 30.04.2026 · 15 (9) · 3439
DOI: 10.3390/jcm15093439 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 30.04.2026. Verfasst von Noriko Toyokawa und 3 weiteren Autor:innen. Beteiligte Einrichtung: Nagata Eye Clinic, 1147 Kitayamada Horai, Nara City 631-0844, Nara, Japan. Die Arbeit nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background/Objectives: A disadvantage of Descemet stripping automated endothelial keratoplasty (DSAEK) in eyes with prior glaucoma filtration surgery is the difficulty in maintaining air tamponade during the procedure. Herein, we report the use of bleb compressive sutures in managing air tamponade in the anterior chamber during DSAEK in eyes with blebs following trabeculectomy.
Methods
This retrospective case series included 34 eyes of 33 patients that developed bullous keratopathy following trabeculectomy. Bleb compression suturing was performed using a 10-0 nylon suture in eyes with an intraocular pressure (IOP) < 10 mmHg or a fragile ischemic bleb. Postoperative IOP, air ingress into the bleb, rebubbling, bleb leakage, and bleb damage were evaluated.
Results
Of the 34 eyes, 13 underwent bleb compression suturing before DSAEK (suture group), whereas 21 eyes did not (non-suture group). The mean preoperative IOP was 7.5 ± 2.5 mmHg and 11.2 ± 4.2 mmHg in the suture and the non-suture groups, respectively. The IOP was measured 2 h postoperatively in 14 eyes, increasing by 18 ± 9.3 and 11.7 ± 3.1 mmHg in the suture and non-suture groups, respectively, compared to the preoperative IOP, with no significant differences. At 2 h postoperatively, two eyes in the suture group and one eye in the non-suture group exhibited an IOP spike (≥30 mmHg). One eye in the non-suture group required rebubbling owing to air ingress into the bleb. The mean IOP was 7.1 ± 3.2 and 9.4 ± 4.6 mmHg in the suture and non-suture groups, respectively, 1–2 weeks postoperatively. Preoperative and postoperative IOPs did not significantly differ in either group, and no suture-related complications were observed.
Conclusions
For eyes with blebs, bleb compression suturing in DSAEK provides effective air tamponade during graft adhesion.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Nagata Eye Clinic, 1147 Kitayamada Horai, Nara City 631-0844, Nara, Japan.
- Department of Ophthalmology, Kansai Medical University, 2-5-1 Shinmachi, Hirakata City 573-1010, Osaka, Japan.
ORCID-Profile: Noriko Toyokawa, Kaoru Araki-Sasaki
Zitieren
APA
Toyokawa, N., Araki-Sasaki, K., Kimura, H., & Kuroda, S. (2026). Bleb Compressive Sutures in Descemet Stripping Automated Endothelial Keratoplasty for Eyes with Filtering Blebs Following Trabeculectomy. Journal of Clinical Medicine, 15(9), 3439. https://doi.org/10.3390/jcm15093439
Vancouver
Toyokawa N, Araki-Sasaki K, Kimura H, Kuroda S. Bleb Compressive Sutures in Descemet Stripping Automated Endothelial Keratoplasty for Eyes with Filtering Blebs Following Trabeculectomy. Journal of Clinical Medicine. 2026;15(9):3439. doi:10.3390/jcm15093439
BibTeX
@article{Toyokawa2026,
author = {Toyokawa, Noriko and Araki-Sasaki, Kaoru and Kimura, Hideya and Kuroda, Shinichiro},
title = {Bleb Compressive Sutures in Descemet Stripping Automated Endothelial Keratoplasty for Eyes with Filtering Blebs Following Trabeculectomy},
journal = {Journal of Clinical Medicine},
year = {2026},
volume = {15},
number = {9},
pages = {3439},
doi = {10.3390/jcm15093439}
}
EUVIMED