Early Real-World Clinical Outcomes and Astigmatism Vector Analysis of Toric Intraocular Lenses for High Astigmatism (≥2.0 D)

Silvia Victoria Prodescu iD, Paul Filip Curcă iD, Cătălina Ioana Tătaru iD, Călin Petru Tătaru iD

Journal of Clinical Medicine · 28.04.2026 · 15 (9) · 3343

DOI: 10.3390/jcm15093343 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 28.04.2026. Verfasst von Silvia Victoria Prodescu und 3 weiteren Autor:innen. Beteiligte Einrichtung: Doctoral School, Ophthalmology Department, Carol Davila University of Medicine and Pharmacy, 020021 Bucharest, Romania. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Objectives: Toric intraocular lens (IOL) implantation is the standard approach for correcting corneal astigmatism during cataract surgery and refractive lens exchange (RLE). Evidence on outcomes in eyes with high corneal astigmatism (≥2.00 diopters, D), particularly in heterogeneous real-world settings, remains limited. This study evaluated visual, refractive, and astigmatic vector outcomes of toric IOL implantation in a consecutive high-astigmatism cohort and investigated predictors of residual astigmatic error.

Methods

This single-center, single-surgeon retrospective analysis of prospectively collected data included 161 eyes (118 patients) with preoperative corneal astigmatism ≥ 2.00 D undergoing cataract surgery or RLE with toric IOL implantation (June 2023–December 2025). Primary outcomes at one month included visual acuity, manifest refraction, and Alpins vector analysis at the corneal plane. Secondary analyses comprised refractive stability assessment (n = 75 eyes, median seven months), comparison of astigmatic outcomes between emmetropia-targeted and intentional myopia-targeted eyes, and multivariate regression of predictors of residual astigmatic error.

Results

Mean postoperative UDVA and CDVA were 0.19 ± 0.24 and 0.09 ± 0.15 logMAR, respectively. Spherical equivalent prediction error was −0.19 ± 0.42 D (69.6% within ±0.50 D of target). Mean residual cylinder was 0.52 ± 0.49 D; 62% and 88.8% of eyes achieved ≤0.50 D and ≤1.00 D, respectively. Vector analysis demonstrated a mean difference vector of 0.53 ± 0.44 D, a correction index of 1.04 ± 0.20, and near-zero centroid deviation (0.03 D @ 43°), indicating the absence of systematic directional prediction error. Refractive outcomes were stable at medium-term follow-up. Astigmatic correction accuracy was equivalent between emmetropia-targeted and intentional myopia-targeted eyes (p > 0.05 for all primary metrics). Multivariate regression identified IOL cylinder power (β = 0.051, p = 0.031) and oblique astigmatism orientation (β = 0.299 vs. WTR, p = 0.032) as independent predictors of greater residual astigmatic error. No sight-threatening complications occurred.

Conclusions

Toric IOL implantation provides safe, predictable, and stable correction of high corneal astigmatism in a real-world mixed cohort. Astigmatic accuracy is maintained regardless of intended spherical refractive strategy, supporting the use of toric IOLs in highly myopic patients targeted for residual myopia. Oblique astigmatism orientation is an independent predictor of reduced correction accuracy, consistent with known limitations of current toric calculators for this meridian.

Schlagwörter

Stichwörter der Autor:innen

Alpins methodcataract surgeryhigh astigmatismoblique astigmatismreal-world outcomesrefractive lens exchangetoric intraocular lensvector analysis

Autor:innen und Institutionen

  • Doctoral School, Ophthalmology Department, Carol Davila University of Medicine and Pharmacy, 020021 Bucharest, Romania.
  • Ophthalmology Department, Alcor Clinic, 030836 Bucharest, Romania.
  • Ophthalmology Department, Central Military Emergency University Hospital "Dr. Carol Davila", Carol Davila University of Medicine and Pharmacy, 010825 Bucharest, Romania.
  • Ophthalmology Department, Clinical Institute for Ophthalmological Emergencies "Prof. Dr. Mircea Olteanu", Carol Davila University of Medicine and Pharmacy, 010464 Bucharest, Romania.
  • Ophthalmology Department, Clinical Institute for Ophthalmological Emergencies "Prof. Dr. Mircea Olteanu", 010464 Bucharest, Romania.

ORCID-Profile: Silvia Victoria Prodescu, Paul Filip Curcă, Cătălina Ioana Tătaru, Călin Petru Tătaru

Zitieren

APA

Prodescu, S. V., Curcă, P. F., Tătaru, C. I., & Tătaru, C. P. (2026). Early Real-World Clinical Outcomes and Astigmatism Vector Analysis of Toric Intraocular Lenses for High Astigmatism (≥2.0 D). Journal of Clinical Medicine, 15(9), 3343. https://doi.org/10.3390/jcm15093343

Vancouver

Prodescu SV, Curcă PF, Tătaru CI, Tătaru CP. Early Real-World Clinical Outcomes and Astigmatism Vector Analysis of Toric Intraocular Lenses for High Astigmatism (≥2.0 D). Journal of Clinical Medicine. 2026;15(9):3343. doi:10.3390/jcm15093343

BibTeX
@article{Prodescu2026,
  author = {Prodescu, Silvia Victoria and Curcă, Paul Filip and Tătaru, Cătălina Ioana and Tătaru, Călin Petru},
  title = {Early Real-World Clinical Outcomes and Astigmatism Vector Analysis of Toric Intraocular Lenses for High Astigmatism (≥2.0 D)},
  journal = {Journal of Clinical Medicine},
  year = {2026},
  volume = {15},
  number = {9},
  pages = {3343},
  doi = {10.3390/jcm15093343}
}
Kostenlos starten →