EUVIMEDEUVIMED entdecken
ÜbersichtsarbeitSystematische ÜbersichtOpen Access · CC BY 4.0

Diagnostic Accuracy of Dual Energy CT for Bone Marrow Edema of the Sacroiliac Joints Compared with MRI: A Systematic Review

Armando Perrella iD, Nunzia Di Meglio iD, Giulio Bagnacci, Paolo Tini iD, Giandomenico Roviello iD, Nicole Martini, Chiara Piscitello iD, Chiara Giraudo iD, Luca Cantarini iD, Bruno Frediani, Maria Antonietta Mazzei iD

Journal of Clinical Medicine · 27.04.2026 · 15 (9) · 3337

DOI: 10.3390/jcm15093337 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Journal of Clinical Medicine, online erschienen am 27.04.2026. Verfasst von Armando Perrella und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical, Surgical and Neuro Sciences, University of Siena, 53100 Siena, Italy. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Dual-energy computed tomography (DECT) with virtual non-calcium (VNCa) reconstruction is emerging as an alternative method for identifying bone marrow edema (BME) in cases of inflammatory sacroiliitis, especially when magnetic resonance imaging (MRI) is contraindicated or unavailable.

Objectives

The aim of this systematic review and meta-analysis is to evaluate the diagnostic performance of DECT with VNCa reconstruction for detecting BME in inflammatory sacroiliitis, using MRI as the reference standard.

Methods

Following PRISMA-DTA guidelines and a pre-registered PROSPERO protocol (CRD420251103652), we searched PubMed, Web of Science, and the Cochrane Library up to June 2025. Seven studies comprising 358 patients and 591 sacroiliac joints were included. Quality assessment was performed using QUADAS-2. Pooled sensitivity and specificity were calculated using a bivariate random-effects regression model. Heterogeneity was evaluated using the I2 statistic. Subgroup analyses were performed for anatomical site and slice thickness, along with a meta-regression according to anatomical site. Publication bias was assessed using Deeks’ test.

Results

Quality assessment revealed a moderate risk of bias, primarily related to patient selection. The pooled sensitivity and specificity of DECT VNCa were 78% (95% CI: 65–88%) and 83% (95% CI: 71–91%), respectively. The area under the SROC curve was 0.91 (95% CI: 0.88–0.93), indicating good diagnostic accuracy. Heterogeneity was moderate for sensitivity (I2 ≈ 68%) and high for specificity (I2 ≈ 88%), largely driven by one outlier study. Sensitivity was lower for sacral BME than for iliac BME (69% vs 79%), although this difference did not reach statistical significance (p ≈ 0.07). Specificity tended to be higher with slice thickness ≥1 mm than with

Schlagwörter

Stichwörter der Autor:innen

Dual-Energy CTankylosing spondylitisaxial spondyloarthritisbone marrow edemainflammatory sacroiliitismeta-analysissystematic reviewvirtual non-calcium

Autor:innen und Institutionen

  • Department of Medical, Surgical and Neuro Sciences, University of Siena, 53100 Siena, Italy.
  • Unit of Diagnostic Imaging, Department of Medical Sciences, Azienda Ospedaliero-Universitaria Senese, 53100 Siena, Italy.
  • Unit of Radiation Oncology, Oncological Department, Azienda Ospedaliero-Universitaria Senese, 53100 Siena, Italy.
  • Department of Health Sciences, University of Florence, 50134 Florence, Italy.
  • Department of Cardiac, Thoracic, Vascular Sciences and Public Health-DCTV, University of Padova, 35122 Padova, Italy.
  • Rheumatology Unit, Department of Medical Sciences, Azienda Ospedaliero-Universitaria Senese, 53100 Siena, Italy.

ORCID-Profile: Armando Perrella, Nunzia Di Meglio, Paolo Tini, Giandomenico Roviello, Chiara Piscitello, Chiara Giraudo, Luca Cantarini, Maria Antonietta Mazzei

Zitieren

APA

Perrella, A., Di Meglio, N., Bagnacci, G., Tini, P., Roviello, G., Martini, N., Piscitello, C., Giraudo, C., Cantarini, L., Frediani, B., & Mazzei, M. A. (2026). Diagnostic Accuracy of Dual Energy CT for Bone Marrow Edema of the Sacroiliac Joints Compared with MRI: A Systematic Review. Journal of Clinical Medicine, 15(9), 3337. https://doi.org/10.3390/jcm15093337

Vancouver

Perrella A, Di Meglio N, Bagnacci G, Tini P, Roviello G, Martini N, et al. Diagnostic Accuracy of Dual Energy CT for Bone Marrow Edema of the Sacroiliac Joints Compared with MRI: A Systematic Review. Journal of Clinical Medicine. 2026;15(9):3337. doi:10.3390/jcm15093337

BibTeX
@article{Perrella2026,
  author = {Perrella, Armando and Di Meglio, Nunzia and Bagnacci, Giulio and Tini, Paolo and Roviello, Giandomenico and Martini, Nicole and Piscitello, Chiara and Giraudo, Chiara and Cantarini, Luca and Frediani, Bruno and Mazzei, Maria Antonietta},
  title = {Diagnostic Accuracy of Dual Energy CT for Bone Marrow Edema of the Sacroiliac Joints Compared with MRI: A Systematic Review},
  journal = {Journal of Clinical Medicine},
  year = {2026},
  volume = {15},
  number = {9},
  pages = {3337},
  doi = {10.3390/jcm15093337}
}
Kostenlos starten →