EUVIMEDEUVIMED entdecken
FallberichtOpen Access · CC BY 4.0

Combined Bentall, Coronary Artery Bypass Grafting and Implantation of Ascyrus Medical Dissection Stent Landed Inside a Thoracic Endovascular Aortic Repair Stent

Robert Grant, Pouya Nezafati, Bruce French

Journal of Clinical Medicine · 27.04.2026 · 15 (9) · 3329

DOI: 10.3390/jcm15093329 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Journal of Clinical Medicine, online erschienen am 27.04.2026. Verfasst von Robert Grant und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiothoracic Surgery, Liverpool Hospital, Sydney, NSW 2170, Australia. Die Arbeit nennt 10 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Acute type A aortic dissection (ATAAD) is a life-threatening condition that may be complicated by malperfusion, particularly in patients with prior aortic interventions such as Thoracic Endovascular Aortic Repair (TEVAR). Management becomes increasingly complex when the dissection involves supra-aortic branches and compromises previously placed stents.

Methods

We report the case of a 58-year-old male presenting with ATAAD and left lower limb paralysis, with a history of prior TEVAR. Imaging demonstrated an entry tear in the ascending aorta with extension into the distal left main and supra-aortic branches, resulting in a dissection flap obstructing the proximal end of the TEVAR stent. The patient underwent emergency surgical intervention including a Bentall procedure, coronary artery bypass grafting (CABG), and deployment of a small Ascyrus Medical Dissection Stent (AMDS) distally within the TEVAR stent. Pre-operatively, the patient had severe lower limb ischemia due to near-complete obstruction of distal flow.

Results

Following surgical intervention, there was restoration of true lumen perfusion with resolution of malperfusion. The patient was successfully weaned from cardiopulmonary bypass, extubated on post-operative day 4, and discharged on day 7 with stable hemodynamics and intact bilateral lower limb perfusion. Post-operative computed tomography (CT) demonstrated a well-seated AMDS with no evidence of ongoing false lumen perfusion. At 30-day follow-up, there was no clinical or biochemical evidence of organ malperfusion.

Conclusions

The use of an AMDS deployed within a pre-existing TEVAR stent may represent an effective strategy for managing complex ATAAD with malperfusion, particularly in cases requiring combined surgical interventions.

Schlagwörter

Stichwörter der Autor:innen

AMDSacute type A aortic dissectionaortic root surgerydissection stent

Autor:innen und Institutionen

  • Department of Cardiothoracic Surgery, Liverpool Hospital, Sydney, NSW 2170, Australia.
  • Department of Cardiothoracic Surgery, John Hunter Hospital, Newcastle, NSW 2305, Australia.

Zitieren

APA

Grant, R., Nezafati, P., & French, B. (2026). Combined Bentall, Coronary Artery Bypass Grafting and Implantation of Ascyrus Medical Dissection Stent Landed Inside a Thoracic Endovascular Aortic Repair Stent. Journal of Clinical Medicine, 15(9), 3329. https://doi.org/10.3390/jcm15093329

Vancouver

Grant R, Nezafati P, French B. Combined Bentall, Coronary Artery Bypass Grafting and Implantation of Ascyrus Medical Dissection Stent Landed Inside a Thoracic Endovascular Aortic Repair Stent. Journal of Clinical Medicine. 2026;15(9):3329. doi:10.3390/jcm15093329

BibTeX
@article{Grant2026,
  author = {Grant, Robert and Nezafati, Pouya and French, Bruce},
  title = {Combined Bentall, Coronary Artery Bypass Grafting and Implantation of Ascyrus Medical Dissection Stent Landed Inside a Thoracic Endovascular Aortic Repair Stent},
  journal = {Journal of Clinical Medicine},
  year = {2026},
  volume = {15},
  number = {9},
  pages = {3329},
  doi = {10.3390/jcm15093329}
}
Kostenlos starten →