Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 21.04.2026. Verfasst von Mehmet Ali Durmuş und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Sakarya University Training and Research Hospital, 54100 Sakarya, Turkey. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background/Objectives: Brain death determination in children is clinically challenging. When standard clinical examination cannot be completed or reliably interpreted, ancillary testing is required—yet many established methods depend on infrastructure or patient transport that may not be feasible in critically ill pediatric patients. Orbital ultrasonography is bedside-applicable and non-invasive, but remains poorly characterized in children.
Methods
We conducted a single-center retrospective study of 28 pediatric patients evaluated for suspected brain death between January 2021 and February 2025. Patients were classified as brain death-positive [BD(+), n = 20] or brain death-negative [BD(−), n = 8] based on clinical criteria independent of imaging findings. Orbital color Doppler parameters (ophthalmic artery, central retinal artery, posterior ciliary artery) and optic nerve sheath diameter (ONSD) were measured under a standardized protocol by a single experienced operator. Ophthalmic artery resistive index (OA-RI) was defined a priori as the primary outcome; ONSD was the secondary outcome. Group comparisons used the Mann–Whitney U test with Cliff’s delta effect sizes; false discovery rate correction was applied to secondary and exploratory comparisons. ROC analyses were performed to assess discriminative performance. The study was reported in accordance with the STARD 2015 guidelines for diagnostic accuracy research.
Results
OA-RI was markedly higher in BD(+) patients (0.84 [IQR 0.80–0.90] vs. 0.65 [0.58–0.69]; p < 0.001; δ = 0.975). ROC analysis yielded an AUC of 0.99 (95% CI: 0.96–1.00); at a cut-off of ≥0.77, sensitivity was 95.0% and specificity 100.0%. ONSD also differed significantly between groups (4.75 [4.15–5.08] mm vs. 3.90 [3.40–4.15] mm; p = 0.012; δ = 0.619; AUC = 0.81, 95% CI: 0.62–1.00; cut-off ≥ 4.2 mm; sensitivity and specificity both 75.0%). Across all three orbital vessels, end-diastolic velocity was consistently reduced and resistive indices elevated in BD(+) patients. Systolic velocities did not differ meaningfully between groups. Cut-off values represent cohort-specific statistical optima and should be interpreted as exploratory.
Conclusions
Orbital Doppler ultrasonography demonstrates a coherent high-resistance hemodynamic pattern in pediatric brain death. OA-RI showed strong discriminative performance and may serve as a useful bedside adjunct in selected cases where ancillary testing is indicated. ONSD provides complementary anatomical evidence. These findings are exploratory and require prospective validation in larger, multicenter pediatric cohorts.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Sakarya University Training and Research Hospital, 54100 Sakarya, Turkey.
- Department of Pediatric Intensive Care, Sakarya University Training and Research Hospital, 54100 Sakarya, Turkey.
- Department of Radiology, Gaziantep City Hospital, 27470 Gaziantep, Turkey.
- Department of Radiology, Ağrı Training and Research Hospital, 04100 Ağrı, Turkey.
ORCID-Profile: Alper Karacan, Onur Taydaş, Zeynep Yıldız, Laçin Tatlı Ayhan, Mustafa Özdemir
Zitieren
APA
Durmuş, M. A., Karacan, A., Taydaş, O., Arslanoğlu, M. Ö., Yıldız, Z., Paşa, O., Taşdoğan, S., Dertli, T., Tatlı Ayhan, L., Özdemir, M., & Öztürk, M. H. (2026). Orbital Doppler Ultrasonography and Optic Nerve Sheath Diameter in Pediatric Brain Death Evaluation. Journal of Clinical Medicine, 15(8), 3156. https://doi.org/10.3390/jcm15083156
Vancouver
Durmuş MA, Karacan A, Taydaş O, Arslanoğlu MÖ, Yıldız Z, Paşa O, et al. Orbital Doppler Ultrasonography and Optic Nerve Sheath Diameter in Pediatric Brain Death Evaluation. Journal of Clinical Medicine. 2026;15(8):3156. doi:10.3390/jcm15083156
BibTeX
@article{Durmu2026,
author = {Durmuş, Mehmet Ali and Karacan, Alper and Taydaş, Onur and Arslanoğlu, Mehmet Özgür and Yıldız, Zeynep and Paşa, Onur and Taşdoğan, Sinan and Dertli, Tunahan and Tatlı Ayhan, Laçin and Özdemir, Mustafa and Öztürk, Mehmet Halil},
title = {Orbital Doppler Ultrasonography and Optic Nerve Sheath Diameter in Pediatric Brain Death Evaluation},
journal = {Journal of Clinical Medicine},
year = {2026},
volume = {15},
number = {8},
pages = {3156},
doi = {10.3390/jcm15083156}
}
EUVIMED