Peak Inspiratory Flow Capability for Simulated Dry Powder Inhaler Resistances in Asthma Patients Prescribed Pressurized Metered-Dose Inhalers with Valved Holding Chambers: The USE-DPI Study
Journal of Clinical Medicine · 20.04.2026 · 15 (8) · 3131
DOI: 10.3390/jcm15083131 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 20.04.2026. Verfasst von Lara Bravo Quiroga und 5 weiteren Autor:innen. Beteiligte Einrichtung: Hospital Universitario Príncipe de Asturias, Alcalá de Henares, 28805 Madrid, Spain. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Orion Corporation (Finland), Orion Company.
Abstract (Originalsprache)
Background
Inhaled therapy is the mainstay of asthma management, yet many patients are prescribed pressurized metered-dose inhalers (pMDIs) with valved holding chambers (VHCs) based on a presumed low inspiratory capacity, often without objective measurement. The USE-DPI study aimed to determine how many of these patients can generate sufficient peak inspiratory flow (PIF) to use a dry powder inhaler (DPI).
Methods
This multicenter, observational, cross-sectional study included 346 patients with asthma treated with pMDI and VHC. PIF was measured using the In-Check Dial at two resistance settings (R2 and R4). The primary outcome was the proportion of patients achieving PIF ≥ 30 L/min.
Results
Almost all patients reached the 30 L/min threshold (99.4% at R2 and 98.7% at R4). Using a higher threshold of 60 L/min (R2), 76.1% met this criterion. Lower PIF (
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Hospital Universitario Príncipe de Asturias, Alcalá de Henares, 28805 Madrid, Spain.
- Escuela de Doctorado, Universidad de Alcalá, 28801 Madrid, Spain.
- Departamento de Medicina y Especialidades, Universidad de Alcalá, 28801 Madrid, Spain.
- Hospital Universitario Virgen del Rocío, 41013 Sevilla, Spain.
- Centro de Salud Doctor Carles Ribas, 08038 Barcelona, Spain.
- Hospital Universitario de Guadalajara, 19002 Guadalajara, Spain.
ORCID-Profile: José Miguel González Moro, Francisco Javier Álvarez-Gutiérrez, José Luis Izquierdo Alonso
Förderung
- Orion Corporation (Finland)
- Orion Company
Zitieren
APA
Bravo Quiroga, L., González Moro, J. M., Álvarez-Gutiérrez, F. J., Baynova, K., De La Poza Abad, M., & Izquierdo Alonso, J. L. (2026). Peak Inspiratory Flow Capability for Simulated Dry Powder Inhaler Resistances in Asthma Patients Prescribed Pressurized Metered-Dose Inhalers with Valved Holding Chambers: The USE-DPI Study. Journal of Clinical Medicine, 15(8), 3131. https://doi.org/10.3390/jcm15083131
Vancouver
Bravo Quiroga L, González Moro JM, Álvarez-Gutiérrez FJ, Baynova K, De La Poza Abad M, Izquierdo Alonso JL. Peak Inspiratory Flow Capability for Simulated Dry Powder Inhaler Resistances in Asthma Patients Prescribed Pressurized Metered-Dose Inhalers with Valved Holding Chambers: The USE-DPI Study. Journal of Clinical Medicine. 2026;15(8):3131. doi:10.3390/jcm15083131
BibTeX
@article{BravoQuiroga2026,
author = {Bravo Quiroga, Lara and González Moro, José Miguel and Álvarez-Gutiérrez, Francisco Javier and Baynova, Krasimira and De La Poza Abad, Mariam and Izquierdo Alonso, José Luis},
title = {Peak Inspiratory Flow Capability for Simulated Dry Powder Inhaler Resistances in Asthma Patients Prescribed Pressurized Metered-Dose Inhalers with Valved Holding Chambers: The USE-DPI Study},
journal = {Journal of Clinical Medicine},
year = {2026},
volume = {15},
number = {8},
pages = {3131},
doi = {10.3390/jcm15083131}
}