Radiographic Clarity of the External Auditory Meatus as a Cranial Reference Point in Spinal Deformity Patients: A Pilot Interobserver Study
Journal of Clinical Medicine · 14.04.2026 · 15 (8) · 2971
DOI: 10.3390/jcm15082971 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 14.04.2026. Verfasst von Dongkyu Kim und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, The Spine and Spinal Cord Institute, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul 06273, Repu…. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background/Objectives: The external auditory meatus (EAM) is widely used as a surrogate cranial reference point, based on its proximity to the midpoint of the nasion–inion line (MNI). However, its radiographic clarity has not been thoroughly validated. This study aimed to evaluate the radiographic clarity and interobserver reproducibility of the EAM compared with the sella turcica as a control landmark.
Methods
A retrospective review was performed on patients who underwent surgical correction for sagittal spinal deformity between 2021 and 2024. Preoperative standing whole-spine radiographs were analyzed. Horizontal and vertical distances from the EAM and the posterior border of the sella turcica to the MNI were measured. Radiographic clarity was categorized into three groups. Five independent neurosurgeons conducted all measurements, and interobserver reliability was assessed using the intraclass correlation coefficient with a two-way random-effects model [ICC(2,1)].
Results
The EAM was horizontally closer to the MNI (1.1 mm vs. 13.8 mm) but exhibited poorer radiographic clarity, with only 14.1% classified as single point and clear compared with 84.5% for the sella turcica. Interobserver reproducibility was lower for the EAM (ICC: 0.84 horizontal, 0.89 vertical) than for the sella turcica (0.97, 0.95). Horizontal deviation among observers was significantly greater for the EAM (major deviation 6.3 mm vs. 2.2 mm, p < 0.001), whereas vertical deviation did not differ significantly.
Conclusions
Although anatomically close to the MNI, the EAM demonstrated inferior radiographic clarity and reproducibility. These findings suggest that the EAM may have limitations as a cranial reference landmark.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Neurosurgery, The Spine and Spinal Cord Institute, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul 06273, Republic of Korea.
- Department of Neurosurgery, Ajou University Medical Center, Suwon-si 16499, Republic of Korea.
ORCID-Profile: Dongkyu Kim, Sejun Park, Keun Su Kim, Pyung Goo Cho, Bong Ju Moon
Zitieren
APA
Kim, D., Chin, D. K., Park, S., Kim, J., Lee, I., Ha, J. W., Jang, H. J., Kim, K. H., Park, J. Y., Kuh, S. U., Kim, K. S., Cho, P. G., & Moon, B. J. (2026). Radiographic Clarity of the External Auditory Meatus as a Cranial Reference Point in Spinal Deformity Patients: A Pilot Interobserver Study. Journal of Clinical Medicine, 15(8), 2971. https://doi.org/10.3390/jcm15082971
Vancouver
Kim D, Chin DK, Park S, Kim J, Lee I, Ha JW, et al. Radiographic Clarity of the External Auditory Meatus as a Cranial Reference Point in Spinal Deformity Patients: A Pilot Interobserver Study. Journal of Clinical Medicine. 2026;15(8):2971. doi:10.3390/jcm15082971
BibTeX
@article{Kim2026,
author = {Kim, Dongkyu and Chin, Dong Kyu and Park, Sejun and Kim, Jaemin and Lee, Insu and Ha, Jun-Woo and Jang, Hyun Jun and Kim, Kyung Hyun and Park, Jeong Yoon and Kuh, Sung Uk and Kim, Keun Su and Cho, Pyung Goo and Moon, Bong Ju},
title = {Radiographic Clarity of the External Auditory Meatus as a Cranial Reference Point in Spinal Deformity Patients: A Pilot Interobserver Study},
journal = {Journal of Clinical Medicine},
year = {2026},
volume = {15},
number = {8},
pages = {2971},
doi = {10.3390/jcm15082971}
}
EUVIMED