Impact of In-House 3D-Printed Models on Re-Operation Rates and Volumetric Precision in Orbital Floor Reconstruction: A Comparative Study
Journal of Clinical Medicine · 08.04.2026 · 15 (8) · 2822
DOI: 10.3390/jcm15082822 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 08.04.2026. Verfasst von Ilze Prikule und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oral and Maxillofacial Surgery, Riga Stradins University, LV-1007 Riga, Latvia. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: BBCE-Baltic Biomaterials Centre of Excellence, EU research and innovation program, Ministry of Economics Republic of Latvia project "State research project in the field of biomedicine, medical technologies, and pharmacy (BioMedPharm)" project.
Abstract (Originalsprache)
Background/Objectives: Reconstruction of orbital floor fractures remains surgically challenging due to limited intraoperative visibility and complex anatomy. Inaccurate implant placement often leads to persistent complications and the need for a revision surgery. This study evaluated the clinical accuracy and re-operation rates of a preoperative 3D-printed model-assisted technique compared to the conventional intraoperative free-hand mesh bending method.
Methods
A comparative ambispective study was conducted on 74 patients with isolated orbital floor fractures. The control group (n = 34, retrospective) underwent reconstruction using intraoperatively formed titanium meshes. In the study group (n = 40, prospective), patient-specific 3D-printed models, created by mirroring the healthy contralateral orbit, were used for preoperative mesh adaptation. Primary outcomes included the rate of revision surgery due to implant malposition, changes in orbital volume, and postoperative diplopia.
Results
The 3D model group demonstrated a significantly lower rate of revision surgery compared to the control group. In the retrospective group, 5 patients (15%) required reoperation due to implant malposition, whereas no patients (0%) in the prospective 3D group required secondary intervention (p = 0.017). While both techniques effectively restored orbital volume, the 3D group showed greater volumetric precision with less variance. The mean volume difference in the affected orbit was 3078 ± 2204 mm3 in the control group, compared to 2390 ± 1893 mm3 in the study 3D group. At the 6-month follow-up, persistent diplopia was observed in 12% of the control group compared to only 3% in the study group.
Conclusions
The use of in-house 3D-printed models for preoperative mesh forming significantly enhances surgical precision and eliminates the need for revision surgery due to implant malposition. This workflow offers a cost-effective, predictable, and accessible alternative to expensive patient-specific implants (PSIs) or intraoperative navigation systems, improving patient safety and long-term clinical outcomes.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Oral and Maxillofacial Surgery, Riga Stradins University, LV-1007 Riga, Latvia.
- Centre of Oral and Maxillofacial Surgery, Pauls Stradins Clinical University Hospital, LV-1002 Riga, Latvia.
- Baltic Biomaterial Centre of Excellence, Headquarters at Riga Technical University, LV-1048 Riga, Latvia.
- Institute of Stomatology, Riga Stradins University, LV-1007 Riga, Latvia.
ORCID-Profile: Ilze Prikule, Ieva Bagante, Oskars Radzins
Förderung
- BBCE-Baltic Biomaterials Centre of Excellence
- EU research and innovation program
- Ministry of Economics Republic of Latvia project "State research project in the field of biomedicine, medical technologies, and pharmacy (BioMedPharm)" project
- BBCE—Baltic Biomaterials Centre of Excellence
- Ministry of Economics Republic of Latvia
Zitieren
APA
Prikule, I., Bagante, I., Radzins, O., & Salms, G. (2026). Impact of In-House 3D-Printed Models on Re-Operation Rates and Volumetric Precision in Orbital Floor Reconstruction: A Comparative Study. Journal of Clinical Medicine, 15(8), 2822. https://doi.org/10.3390/jcm15082822
Vancouver
Prikule I, Bagante I, Radzins O, Salms G. Impact of In-House 3D-Printed Models on Re-Operation Rates and Volumetric Precision in Orbital Floor Reconstruction: A Comparative Study. Journal of Clinical Medicine. 2026;15(8):2822. doi:10.3390/jcm15082822
BibTeX
@article{Prikule2026,
author = {Prikule, Ilze and Bagante, Ieva and Radzins, Oskars and Salms, Girts},
title = {Impact of In-House 3D-Printed Models on Re-Operation Rates and Volumetric Precision in Orbital Floor Reconstruction: A Comparative Study},
journal = {Journal of Clinical Medicine},
year = {2026},
volume = {15},
number = {8},
pages = {2822},
doi = {10.3390/jcm15082822}
}
EUVIMED