EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Experience of Alternative Technique for Branch Cannulation in Branched Endovascular Aneurysm Repair

Daniela Mazzaccaro iD, Paolo C Righini iD, Fabiana Fancoli, Alfredo Modafferi, Giovanni Malacrida, Marina Galligani, Giovanni Nano

Journal of Clinical Medicine · 24.03.2026 · 15 (7) · 2497

DOI: 10.3390/jcm15072497 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 24.03.2026. Verfasst von Daniela Mazzaccaro und 6 weiteren Autor:innen. Beteiligte Einrichtung: Operative Unit of Vascular Surgery, IRCCS Policlinico San Donato, San Donato Milanese, 20097 Milan, Italy. Die Arbeit nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Objectives: To describe our experience of using an alternative technique for retrograde branch graft cannulation during Branched EndoVascular Aortic Repair (B-EVAR) of complex abdominal and thoraco-abdominal aortic aneurysm (TAAA) with branched endografts.

Methods

Data from patients who underwent B-EVAR for TAAA/complex abdominal aneurysms and in whom the cannulation of a branch was performed through a retrograde approach with our technique were retrospectively collected and analyzed. The technique consists of the placement of two 4F Ber catheters in both femoral arteries, which are advanced in parallel with the main graft before its deployment and left in the aneurysmal sac. These catheters are then used as a bailout for the retrograde cannulation of one or more branches of the endograft.

Results

The technique was employed in 4 patients (1 female, 1 urgent) treated from 2018 onward, allowing the successful catheterization of 4 challenging branches that could not be catheterized using other approaches. The patients’ mean age was 80.7 + 2.2 years. No intraoperative nor postoperative complications linked to the technique occurred.

Conclusions

The placement of two catheters from both femoral arteries inside the aneurysmal sac before graft deployment can be safe and useful for bailout retrograde cannulation of any branch of the endograft, when other techniques fail.

Schlagwörter

Stichwörter der Autor:innen

B-EVARaneurysmbranch cannulationthoraco-abdominal

Autor:innen und Institutionen

  • Operative Unit of Vascular Surgery, IRCCS Policlinico San Donato, San Donato Milanese, 20097 Milan, Italy.
  • Department of Biomedical Sciences for Health, University of Milan, 20122 Milan, Italy.

ORCID-Profile: Daniela Mazzaccaro, Paolo C Righini

Zitieren

APA

Mazzaccaro, D., Righini, P. C., Fancoli, F., Modafferi, A., Malacrida, G., Galligani, M., & Nano, G. (2026). Experience of Alternative Technique for Branch Cannulation in Branched Endovascular Aneurysm Repair. Journal of Clinical Medicine, 15(7), 2497. https://doi.org/10.3390/jcm15072497

Vancouver

Mazzaccaro D, Righini PC, Fancoli F, Modafferi A, Malacrida G, Galligani M, et al. Experience of Alternative Technique for Branch Cannulation in Branched Endovascular Aneurysm Repair. Journal of Clinical Medicine. 2026;15(7):2497. doi:10.3390/jcm15072497

BibTeX
@article{Mazzaccaro2026,
  author = {Mazzaccaro, Daniela and Righini, Paolo C and Fancoli, Fabiana and Modafferi, Alfredo and Malacrida, Giovanni and Galligani, Marina and Nano, Giovanni},
  title = {Experience of Alternative Technique for Branch Cannulation in Branched Endovascular Aneurysm Repair},
  journal = {Journal of Clinical Medicine},
  year = {2026},
  volume = {15},
  number = {7},
  pages = {2497},
  doi = {10.3390/jcm15072497}
}
Kostenlos starten →