Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 24.03.2026. Verfasst von Hyunju Jeong und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Device Engineering and Management, Yonsei University College of Medicine, Seoul 06229, Republic of Korea. Die Arbeit nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Korea Medical Device Development Fund, Korean government Korea Medical Device Development Fund.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Objectives: Hemodynamic monitoring is essential for guiding appropriate treatment by assessing cardiac output and volume status, as well as for preventing complications associated with excessive fluid administration. The EdgeFlow CW10 Plus is a device that extends conventional hemodynamic monitoring by incorporating pulmonary abnormality surveillance through B-line detection. This study aimed to evaluate whether the hemodynamic monitoring and pulmonary monitoring functions are well integrated, and verify the usability and efficiency of the system.

Methods

A usability test was conducted with a panel of 15 medical professionals from diverse specialties and varying levels of clinical experience. Data from satisfaction surveys, heat maps, the System Usability Scale (SUS), and the NASA-TLX were analyzed to determine whether usability differences existed based on the duration of clinical experience.

Results

The device demonstrated a high overall task success rate, averaging 93.2%. Regarding eye-tracking analysis based on clinical experience, it was observed that participants with more years of experience either failed to direct their gaze toward task-relevant user interface (UI) elements as effectively as those with fewer years of experience or showed similar patterns.

Conclusions

The usability evaluation confirmed that the hemodynamic and pulmonary monitoring functions of the EdgeFlow CW 10 PLUS are well integrated, with the device demonstrating high usability and satisfaction. This integration is expected to support medical professionals in monitoring cardiac output and fluid status, facilitating timely therapeutic interventions while preventing complications related to fluid overload.

Schlagwörter

Stichwörter der Autor:innen

eye trackerhemodynamics monitoringlung ultrasound monitoringusability test

Autor:innen und Institutionen

  • Department of Medical Device Engineering and Management, Yonsei University College of Medicine, Seoul 06229, Republic of Korea.
  • Medical Device Usability Research Center, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul 06230, Republic of Korea.

ORCID-Profile: Hyunju Jeong, Hyeonkyeong Choi, Wonseuk Jang

Förderung

  • Korea Medical Device Development Fund
  • Korean government Korea Medical Device Development Fund

Zitieren

APA

Jeong, H., Choi, H., Kim, H., & Jang, W. (2026). Usability Validation of an Integrated Hemodynamic and Pulmonary Monitoring System Using Eye-Tracking Analysis. Journal of Clinical Medicine, 15(7), 2474. https://doi.org/10.3390/jcm15072474

Vancouver

Jeong H, Choi H, Kim H, Jang W. Usability Validation of an Integrated Hemodynamic and Pulmonary Monitoring System Using Eye-Tracking Analysis. Journal of Clinical Medicine. 2026;15(7):2474. doi:10.3390/jcm15072474

BibTeX
@article{Jeong2026,
  author = {Jeong, Hyunju and Choi, Hyeonkyeong and Kim, Hyungmin and Jang, Wonseuk},
  title = {Usability Validation of an Integrated Hemodynamic and Pulmonary Monitoring System Using Eye-Tracking Analysis},
  journal = {Journal of Clinical Medicine},
  year = {2026},
  volume = {15},
  number = {7},
  pages = {2474},
  doi = {10.3390/jcm15072474}
}
Kostenlos starten →