Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 19.03.2026. Verfasst von Hong Chan Kim und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otolaryngology-Head and Neck Surgery, Chonnam National University Hospital, Gwangju 61469, Republic of Korea. Die Arbeit nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Health and Welfare, Republic of Korea, Chonnam National University Hospital Biomedical Research Institute.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

Sound field (SF) audiometry is widely used to evaluate aided hearing performance. This study compared the test–retest reliability and between-system equivalence of SF audiometry between a newly designed SF system for small audiometric booths and a conventional SF system.

Methods

Thirty-nine adults using hearing aids (56 tested ears; 19 females [26 ears] and 20 males [30 ears]) underwent aided warble-tone audiometry (0.25, 0.5, 1, 2, and 4 kHz) and aided speech audiometry using a conventional SF system (two loudspeakers at 45° azimuth and 1 m distance) and a newly designed small-booth SF system (two height-adjustable loudspeakers at 45° azimuth and at 30 cm distance). The same sequence was repeated to assess test–retest performance. The test–retest differences were evaluated using paired t-tests, and the variability was summarized using the coefficient of variation (CV). Equivalence of aided warble-tone thresholds between systems was evaluated using two one-sided tests (TOST) with a ±10 dB margin.

Results

Within each system, aided warble-tone thresholds and aided speech reception thresholds (SRTs) did not differ significantly between the test and the retest (all p > 0.05). The warble-tone thresholds were equivalent between systems within the predefined ±10 dB margin by TOST. Aided word recognition scores (WRSs) at 65 dB HL were higher in the newly designed system than in the conventional system (p < 0.0001). The CVs were low in both systems and were slightly lower in the newly designed system.

Conclusions

When the listener-to-loudspeaker position is strictly controlled, SF audiometry provides stable test–retest results in hearing-aid users. The newly designed SF system for small audiometric booths produced aided thresholds equivalent to those of the conventional SF system and yielded higher WRSs at 65 dB HL under the tested conditions.

Schlagwörter

Stichwörter der Autor:innen

audiometryhearing aidshearing lossreproducibility of resultsspeech perception

Autor:innen und Institutionen

  • Department of Otolaryngology-Head and Neck Surgery, Chonnam National University Hospital, Gwangju 61469, Republic of Korea.
  • Department of Otolaryngology-Head and Neck Surgery, Chonnam National University Medical School, Gwangju 61469, Republic of Korea.
  • Department of Otolaryngology-Head and Neck Surgery, College of Medicine, Catholic University of Korea, Seoul 06591, Republic of Korea.
  • Division of Applied Photonics System Research, Advanced Photonics Research Institute (APRI), Gwangju Institute of Science and Technology (GIST), Gwangju 61005, Republic of Korea.

ORCID-Profile: Hwan Min Kim, Hyong-Ho Cho

Förderung

  • Ministry of Health and Welfare, Republic of Korea
  • Chonnam National University Hospital Biomedical Research Institute

Zitieren

APA

Kim, H. C., Kim, H. M., Choi, Y. M., Park, K. H., Bark, H. S., & Cho, H. H. (2026). Comparison of Test–Retest Reliability of Sound Field Audiometry Between a Newly Designed System for Small Audiometric Booths and a Conventional Sound Field System. Journal of Clinical Medicine, 15(6), 2351. https://doi.org/10.3390/jcm15062351

Vancouver

Kim HC, Kim HM, Choi YM, Park KH, Bark HS, Cho HH. Comparison of Test–Retest Reliability of Sound Field Audiometry Between a Newly Designed System for Small Audiometric Booths and a Conventional Sound Field System. Journal of Clinical Medicine. 2026;15(6):2351. doi:10.3390/jcm15062351

BibTeX
@article{Kim2026,
  author = {Kim, Hong Chan and Kim, Hwan Min and Choi, Young Mi and Park, Kyoung-Ho and Bark, Hyeon Sang and Cho, Hyong-Ho},
  title = {Comparison of Test–Retest Reliability of Sound Field Audiometry Between a Newly Designed System for Small Audiometric Booths and a Conventional Sound Field System},
  journal = {Journal of Clinical Medicine},
  year = {2026},
  volume = {15},
  number = {6},
  pages = {2351},
  doi = {10.3390/jcm15062351}
}
Kostenlos starten →