Procedural and Device Neutrality of Post-TAVI Renal Outcomes: A Multivariable Analysis of Valve Type, Size, and Anatomy
Journal of Clinical Medicine · 12.03.2026 · 15 (6) · 2175
DOI: 10.3390/jcm15062175 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 12.03.2026. Verfasst von Rosa Alba Pugliesi und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedicine, Neuroscience and Advanced Diagnostics (BiND), University of Palermo, Via del Vespro 129, 90127 Palermo, Italy. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Renal dysfunction remains a frequent complication after transcatheter aortic valve implantation (TAVI). Although contrast exposure and baseline renal impairment are established risk factors, the influence of structural valve characteristics, including valve diameter and prosthesis platform, on early renal outcomes is not well defined. This study evaluated whether valve size and valve platform independently affect early post-procedural renal function.
Methods
This retrospective cohort study included 410 consecutive patients undergoing TAVI between 2018 and 2021 with complete pre- and post-procedural renal biomarker data. Of these, 371 patients with complete covariate data were analyzed in multivariable models. Serum creatinine and estimated glomerular filtration rate (eGFR) were assessed within 72 h before and after TAVI. Renal function change was calculated as absolute differences. Acute kidney injury (AKI) was defined according to KDIGO criteria. Correlation analyses and multivariable linear and logistic regression models were performed.
Results
Median valve diameter was 26 mm (IQR 26–29). Renal function remained largely stable, with a median creatinine change of −0.06 mg/dL and median eGFR change of +4.0 mL/min/1.73 m2. Valve diameter was not associated with creatinine change (ρ = −0.047, p = 0.330) or eGFR change (ρ = 0.053, p = 0.278). KDIGO-defined AKI occurred in 56 patients (13.7%) and did not differ by valve platform (p = 0.719) or diameter tertiles (p = 0.204).
Conclusions
Valve diameter and platform were not independently associated with early renal outcomes after TAVI. Baseline renal function and contrast exposure were the principal determinants of post-procedural renal trajectory.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedicine, Neuroscience and Advanced Diagnostics (BiND), University of Palermo, Via del Vespro 129, 90127 Palermo, Italy.
- Department of Urology, University Hospital OWL, Klinikum Bethel gGmbH, 33611 Bielefeld, Germany.
- Department of Diagnostic and Interventional Radiology, University Hospital of Marburg, 35043 Marburg, Germany.
- Department of Diagnostic and Interventional Radiology, University Hospital of Tübingen, 72076 Tübingen, Germany.
- Department of Cardiology, Angiology, and Intensive Care Medicine, University Hospital, Philipps University of Marburg, 35043 Marburg, Germany.
- Department of Radiology and Nuclear Medicine, Helios Hospital Pforzheim, 75175 Pforzheim, Germany.
ORCID-Profile: Rosa Alba Pugliesi, Nour Maalouf
Zitieren
APA
Pugliesi, R. A., Muna, S. F., Mahken, A. H., Maalouf, N., Chatzis, G., & Apitzsch, J. (2026). Procedural and Device Neutrality of Post-TAVI Renal Outcomes: A Multivariable Analysis of Valve Type, Size, and Anatomy. Journal of Clinical Medicine, 15(6), 2175. https://doi.org/10.3390/jcm15062175
Vancouver
Pugliesi RA, Muna SF, Mahken AH, Maalouf N, Chatzis G, Apitzsch J. Procedural and Device Neutrality of Post-TAVI Renal Outcomes: A Multivariable Analysis of Valve Type, Size, and Anatomy. Journal of Clinical Medicine. 2026;15(6):2175. doi:10.3390/jcm15062175
BibTeX
@article{Pugliesi2026,
author = {Pugliesi, Rosa Alba and Muna, Shu Fon and Mahken, Andreas H and Maalouf, Nour and Chatzis, Georgios and Apitzsch, Jonas},
title = {Procedural and Device Neutrality of Post-TAVI Renal Outcomes: A Multivariable Analysis of Valve Type, Size, and Anatomy},
journal = {Journal of Clinical Medicine},
year = {2026},
volume = {15},
number = {6},
pages = {2175},
doi = {10.3390/jcm15062175}
}
EUVIMED