EUVIMEDEUVIMED entdecken
ÜbersichtsarbeitMetaanalyseOpen Access · CC BY 4.0

Graduated Compression Stockings for Thromboprophylaxis in Orthopaedic and Trauma Surgery: A Rapid Review and Meta-Analysis

Graduierte Kompressionsstrümpfe zur Thromboseprophylaxe in der orthopädischen und Unfallchirurgie: Rapid Review und Metaanalyse

Dirk Stengel, Daniela Schnorbus, Axel Ekkernkamp, Matthias Münzberg, Beate Schmucker, Lina El Kassar, Flemming Rohrmann, Paul A Grützner iD

Journal of Clinical Medicine · 03.12.2025 · 14 (23) · 8578

DOI: 10.3390/jcm14238578 ↗

Auf einen Blick

15 Studien mit 7.721 Patient:innen zeigten keinen klaren Zusatznutzen graduierter Kompressionsstrümpfe bei thromboembolischen Ereignissen. Gegenüber moderner Pharmakoprophylaxe ergab sich kein Vorteil.

Fragestellung

Bringen graduierte Kompressionsstrümpfe zusätzlich zur modernen medikamentösen Thromboseprophylaxe einen Nutzen in der orthopädischen und Unfallchirurgie?

Methode

Prospektiv registrierter Rapid Review und Metaanalyse; Suche in PubMed, Ovid MEDLINE, Embase, CINAHL und CENTRAL vom 1. Januar 1980 bis 1. März 2025; Bewertung mit RoB-2, ROBINS-I und GRADE.

Ergebnisse

15 Untersuchungen (13 RCTs, 2 Beobachtungsstudien) mit 7.721 Patient:innen. Pooled RR für TE-Ereignisse 1,15 (95 %-KI 0,80–1,64; I2: 73 %). 3 Studien ohne Prophylaxe: RR 0,72 (95 %-KI 0,43–1,22).

Einschränkungen

Substanzielle Heterogenität (I2: 73 %).

Schlussfolgerung der Autor:innen

Die Ergebnisse zeigen weder einen klaren Nutzen noch stützen sie den allgemeinen Einsatz graduierter Kompressionsstrümpfe zur TE-Prophylaxe, besonders bei etablierter medikamentöser Prophylaxe.

Kernaussagen

  • Kein klarer Vorteil für gCS bei TE-Ereignissen
  • Pooled RR 1,15 (95 %-KI 0,80–1,64)
  • Die Daten stützen keinen allgemeinen Einsatz bei etablierter Pharmaprophylaxe

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Journal of Clinical Medicine, online erschienen am 03.12.2025. Verfasst von Dirk Stengel und 7 weiteren Autor:innen. Beteiligte Einrichtung: BG Kliniken-Klinikverbund der Gesetzlichen Unfallversicherung gGmbH, Leipziger Pl. 1, 10117 Berlin, Germany. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

Auf einen BlickAbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Objectives: The utility and value of graduated compression stockings (gCS) as an adjunct to pharmacological thromboprophylaxis, with and without low-molecular-weight heparins (LMWH) and other anticoagulants, in avoiding any thromboembolic (TE) event in the scenario of total joint replacement, fracture management, spine and pelvic surgery, and arthroscopic procedures, remains unclear. Because of the urgent need to decide whether gCS should stay in the portfolio of a national group of nine tertiary trauma centres, our research department was requested to answer the question of whether gCS provide any extra benefit in addition to modern TE prophylaxis in orthopaedic and trauma surgery through a prospectively registered rapid review (PROSPERO CRD42024621104).

Methods

We searched PubMed, Ovid MEDLINE, Embase, CINAHL, and CENTRAL from 1 January 1980 to 1 March 2025, for randomised controlled trials (RCTs) and cohort studies comparing TE prophylaxis regimens, both with and without gCS, and modern pharmacological anticoagulants. The methodological quality of individual studies was rated by the Cochrane Collaborations’ Risk of Bias Version 2.0 (RoB-2) and the Risk of Bias in Non-Randomised Studies of Interventions (ROBINS-I) tools, supplemented by the Grading of Recommendations Assessment, Development and Evaluation (GRADE). The reported cumulative incidence of any TE event (i.e., deep vein thrombosis, pulmonary embolism), as defined by individual trialists, was chosen as the primary endpoint, and expressed as the relative risk (RR) between intervention and control groups.

Results

Fifteen investigations (13 RCTs and 2 observational studies) enrolling 7721 patients (mean age, 59 [SD 13] years; 3538 males [46%]) with various musculoskeletal conditions and injuries were included. Methodological quality was deemed sufficient to derive meaningful conclusions. The random-effects pooled RR across all studies was 1.15 (95% confidence interval [CI]: 0.80–1.64) in favour of the no-gCS control, but with substantial heterogeneity (I2: 73%). Only three studies investigated the effectiveness of gCS versus no prophylaxis (N = 246, RR: 0.72, 95% CI: 0.43–1.22). Seven studies (N = 5117) compared various combinations of pharmacological prophylaxis, with or without gCS, for a summary RR of 1.44 (95% CI: 0.76–2.72).

Conclusions

The results of this rapid review neither show a clear benefit nor support the general use of gCS to prevent TE in orthopaedic and trauma surgery, especially if pharmacological prophylactic measures are established and suitable.

Schlagwörter

Stichwörter der Autor:innen

arthroplastycompression stockingsfondaparinuxfractureheparinsorthopedicspelvisprophylaxisspinethromboembolismtrauma

Autor:innen und Institutionen

  • BG Kliniken-Klinikverbund der Gesetzlichen Unfallversicherung gGmbH, Leipziger Pl. 1, 10117 Berlin, Germany.
  • BG Klinikum Unfallkrankenhaus Berlin gGmbH, Warener Str. 7, 12683 Berlin, Germany.
  • BG Unfallklinik Frankfurt am Main, Friedberger Landstr. 430, 60389 Frankfurt am Main, Germany.
  • BG Klinik Ludwigshafen, Ludwig-Guttmann-Str. 13, 67071 Ludwigshafen, Germany.

ORCID-Profile: Paul A Grützner

Zitieren

APA

Stengel, D., Schnorbus, D., Ekkernkamp, A., Münzberg, M., Schmucker, B., El Kassar, L., Rohrmann, F., & Grützner, P. A. (2025). Graduated Compression Stockings for Thromboprophylaxis in Orthopaedic and Trauma Surgery: A Rapid Review and Meta-Analysis. Journal of Clinical Medicine, 14(23), 8578. https://doi.org/10.3390/jcm14238578

Vancouver

Stengel D, Schnorbus D, Ekkernkamp A, Münzberg M, Schmucker B, El Kassar L, et al. Graduated Compression Stockings for Thromboprophylaxis in Orthopaedic and Trauma Surgery: A Rapid Review and Meta-Analysis. Journal of Clinical Medicine. 2025;14(23):8578. doi:10.3390/jcm14238578

BibTeX
@article{Stengel2025,
  author = {Stengel, Dirk and Schnorbus, Daniela and Ekkernkamp, Axel and Münzberg, Matthias and Schmucker, Beate and El Kassar, Lina and Rohrmann, Flemming and Grützner, Paul A},
  title = {Graduated Compression Stockings for Thromboprophylaxis in Orthopaedic and Trauma Surgery: A Rapid Review and Meta-Analysis},
  journal = {Journal of Clinical Medicine},
  year = {2025},
  volume = {14},
  number = {23},
  pages = {8578},
  doi = {10.3390/jcm14238578}
}
Kostenlos starten →