Quantitative Analysis of the Human Face Skin Thickness—A High-Frequency Ultrasound Study
Journal of Clinical Medicine · 27.11.2025 · 14 (23) · 8401
DOI: 10.3390/jcm14238401 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 27.11.2025. Verfasst von Szymon Korzekwa und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anatomy, Poznań University of Medical Sciences, 61-701 Poznan, Poland. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Understanding the topography of facial skin thickness is crucial in plastic surgery and underpins the success of numerous reconstructive, oncological, transplant, volumetric, and aesthetic procedures.
Objective
This study aims to assess facial skin thickness using high-frequency ultrasound, evaluate its correlation with age, anatomical location, and physical parameters, and create a comprehensive facial skin thickness map.
Methods
High-frequency ultrasound (75 MHz, axial resolution 21 μm) was used to scan 38 anatomical sites on the faces of 45 patients aged 22–73 years from esthetic medicine clinics. Measurements were performed manually within the device software. Extensive statistical analysis was conducted to determine dominant thickness values, assess variations by location and age, and evaluate correlations between biometric variables (age, weight, height, BMI) and skin thickness at various facial sites. Based on these findings, a relative thickness index and detailed topographic map of facial skin were developed.
Results
The thickest skin was observed in the lower third of the nose, particularly at the nasal apex (median: 1907 μm, IQR: 455.75 μm, p < 0.001), while the thinnest skin was on the upper eyelid (median: 573.50 μm, IQR: 128.75 μm, p < 0.001). Skin thickness was significantly influenced by anatomical location (p < 0.001, η2 = 0.52), age (p < 0.001, η2 < 0.01), and their interaction (p < 0.001, η2 = 0.04), collectively accounting for approximately 57% of variance in skin thickness. Correlations between biometric parameters and skin thickness were generally weak, though a few strong correlations were found between specific facial sites.
Conclusions
A detailed facial skin thickness map, including a relative thickness index, was developed.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Anatomy, Poznań University of Medical Sciences, 61-701 Poznan, Poland.
- QKA Esthetic Medicine Poznań, 61-553 Poznan, Poland.
- Department of Orthodontics and Temporomandibular Disorders, Poznań University of Medical Sciences, 61-701 Poznan, Poland.
- Aestethic Clinic Poznań, 60-142 Poznan, Poland.
ORCID-Profile: Szymon Korzekwa, Michał Kukulski, Paweł Wawrzaszek, Agnieszka Przystańska
Zitieren
APA
Korzekwa, S., Matusz, K., Kukulski, M., Wawrzaszek, P., Górna, N., Rosiński, W., Włosiański, J., & Przystańska, A. (2025). Quantitative Analysis of the Human Face Skin Thickness—A High-Frequency Ultrasound Study. Journal of Clinical Medicine, 14(23), 8401. https://doi.org/10.3390/jcm14238401
Vancouver
Korzekwa S, Matusz K, Kukulski M, Wawrzaszek P, Górna N, Rosiński W, et al. Quantitative Analysis of the Human Face Skin Thickness—A High-Frequency Ultrasound Study. Journal of Clinical Medicine. 2025;14(23):8401. doi:10.3390/jcm14238401
BibTeX
@article{Korzekwa2025,
author = {Korzekwa, Szymon and Matusz, Krystian and Kukulski, Michał and Wawrzaszek, Paweł and Górna, Natalie and Rosiński, Włodzimierz and Włosiański, Jakub and Przystańska, Agnieszka},
title = {Quantitative Analysis of the Human Face Skin Thickness—A High-Frequency Ultrasound Study},
journal = {Journal of Clinical Medicine},
year = {2025},
volume = {14},
number = {23},
pages = {8401},
doi = {10.3390/jcm14238401}
}
EUVIMED