EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Comparing Conduction System Pacing to Biventricular Upgrade in Pacemaker-Induced Cardiomyopathy: A Retrospective Observational Study

Bernadett Miriam Dobai iD, Balázs Polgár iD, Márk Gémesi iD, Manuella Bogdan iD, Nikolett Vigh iD, Mirjam Turáni iD, Gábor Zoltán Duray iD, Péter Bógyi iD

Journal of Clinical Medicine · 31.10.2025 · 14 (21) · 7745

DOI: 10.3390/jcm14217745 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 31.10.2025. Verfasst von Bernadett Miriam Dobai und 7 weiteren Autor:innen. Beteiligte Einrichtung: Doctoral School of Medicine and Pharmacy, George Emil Palade University of Medicine, Pharmacy, Science and Technology of Targu Mures, 540139 Targu Mu…. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Romanian Society of Cardiology Training Scholarship.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Objectives: Pacemaker-induced cardiomyopathy (PICM) develops in up to 30% of patients with chronic right ventricular pacing. While biventricular (BIV) upgrade is the conventional strategy, conduction system pacing (CSP) offers a physiologic alternative recently endorsed by the 2025 ESC/EHRA Consensus Statement. However, comparative evidence in PICM is limited. Therefore, we aimed to compare outcomes of PICM patients undergoing CSP versus BIV upgrade.

Methods

This retrospective analysis included consecutive PICM patients who were upgraded to CSP or BIV between 2022 and 2024 at a single, experienced center. Follow-up averaged >19 months. Clinical outcomes, lead performance, echocardiographic parameters, complications, and quality of life (QoL) were evaluated.

Results

Sixty-three patients were included (CSP: 26; BIV: 37). Mean age and sex distribution were similar; both groups had wide paced QRS complexes and a high ventricular pacing burden. Baseline left ventricular ejection fraction (LVEF) was lower in BIV patients (29 ± 7% vs. 35 ± 6%, p = 0.01). Procedure duration was comparable, but fluoroscopy was shorter with CSP. QRS duration narrowed significantly in both groups (CSP: 163 ± 28→132 ± 12 ms; BIV: 171 ± 23→140 ± 18 ms; both p < 0.05). During follow-up, LVEF improved (CSP: 41 ± 8%; p = 0.008; BIV: 39 ± 8%, p = 0.0001), as did NYHA class, with no significant intergroup differences. The rates of heart failure hospitalization, all-cause mortality, and QoL were similar. Notably, 34.6% of CSP patients retained their existing generator, suggesting procedural and economic benefits.

Conclusions

CSP is a feasible and potentially cost-efficient alternative to BIV upgrade in PICM, with comparable improvements in ventricular function, symptoms, and clinical outcomes. Larger prospective trials are warranted.

Schlagwörter

Stichwörter der Autor:innen

biventricular pacingcardiac resynchronization therapyconduction system pacingheart failurehis-bundle pacingleft bundle branch area pacingpacemaker-induced cardiomyopathyupgrade procedure

Autor:innen und Institutionen

  • Doctoral School of Medicine and Pharmacy, George Emil Palade University of Medicine, Pharmacy, Science and Technology of Targu Mures, 540139 Targu Mures, Romania.
  • Centre for Translational Medicine, Semmelweis University, 1085 Budapest, Hungary.
  • Central Hospital of Northern Pest-Military Hospital, 1134 Budapest, Hungary.
  • Doctoral College, Semmelweis University, 1085 Budapest, Hungary.
  • Heart and Vascular Center, Semmelweis University, 1124 Budapest, Hungary.

ORCID-Profile: Bernadett Miriam Dobai, Balázs Polgár, Márk Gémesi, Manuella Bogdan, Nikolett Vigh, Mirjam Turáni, Gábor Zoltán Duray, Péter Bógyi

Förderung

  • Romanian Society of Cardiology Training Scholarship

Zitieren

APA

Dobai, B. M., Polgár, B., Gémesi, M., Bogdan, M., Vigh, N., Turáni, M., Duray, G. Z., & Bógyi, P. (2025). Comparing Conduction System Pacing to Biventricular Upgrade in Pacemaker-Induced Cardiomyopathy: A Retrospective Observational Study. Journal of Clinical Medicine, 14(21), 7745. https://doi.org/10.3390/jcm14217745

Vancouver

Dobai BM, Polgár B, Gémesi M, Bogdan M, Vigh N, Turáni M, et al. Comparing Conduction System Pacing to Biventricular Upgrade in Pacemaker-Induced Cardiomyopathy: A Retrospective Observational Study. Journal of Clinical Medicine. 2025;14(21):7745. doi:10.3390/jcm14217745

BibTeX
@article{Dobai2025,
  author = {Dobai, Bernadett Miriam and Polgár, Balázs and Gémesi, Márk and Bogdan, Manuella and Vigh, Nikolett and Turáni, Mirjam and Duray, Gábor Zoltán and Bógyi, Péter},
  title = {Comparing Conduction System Pacing to Biventricular Upgrade in Pacemaker-Induced Cardiomyopathy: A Retrospective Observational Study},
  journal = {Journal of Clinical Medicine},
  year = {2025},
  volume = {14},
  number = {21},
  pages = {7745},
  doi = {10.3390/jcm14217745}
}
Kostenlos starten →