Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 09.09.2025. Verfasst von Maria Oulianski und 4 weiteren Autor:innen. Beteiligte Einrichtung: Orthopedic Department, Hadassah Hebrew University Hospital, Jerusalem POB 12000, Israel. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Operative fixation of displaced midshaft clavicle fractures has become increasingly the more acceptable choice of care in recent years, based on evidence supporting its effectiveness. However, this practice presents challenges due to the complex S-shaped morphology of the clavicle and its subcutaneous location. Despite the introduction of anatomically pre-contoured plates, achieving optimal implant-to-bone fit remains difficult, prompting the development of newer plate generations. The aim of this study was to compare the hardware removal rates of second-generation 2.7 mm thinner plates (SGPs) with those of first-generation 3.5 mm plates (FGPs).

Methods

A retrospective comparative cohort study was conducted at a level one trauma center. A total of 187 patients received FGPs, and 67 received SGPs, both positioned on the superior bone surface. All surgeries were performed by fellowship-trained surgeons, and patients were followed for at least one year. Data were extracted from medical records and the PACS system.

Results

The patients’ demographics (age: 32.86 vs. 33.14 years; gender: 16.85% vs. 14.92% female) and fracture type (AO/OTA) were similar between the two groups. The rate of implant removal (20.1% vs. 20.9%) did not differ significantly between groups. Complications included nonunion (1.6% vs. 1.7%, statistically not significant) and infection (three cases in the FGP group, none in the SGP group).

Conclusions

Despite the high success rate of clavicle fixation procedures, the superior clavicular plate removal rate remains significant, regardless of the implant design.

Schlagwörter

Stichwörter der Autor:innen

clavicle fracturesfixationhardware removalpre-contoured plates

Autor:innen und Institutionen

  • Orthopedic Department, Hadassah Hebrew University Hospital, Jerusalem POB 12000, Israel.

ORCID-Profile: Maria Oulianski, Yoram Weil, Omer Ben Yehuda, Mahmoud Jammal

Zitieren

APA

Oulianski, M., Weil, Y., Ben Yehuda, O., Mosheiff, R., & Jammal, M. (2025). Have New Plate Designs Reduced the Rate of Hardware Removal Following Midshaft Clavicle Fracture Fixation?. Journal of Clinical Medicine, 14(18), 6351. https://doi.org/10.3390/jcm14186351

Vancouver

Oulianski M, Weil Y, Ben Yehuda O, Mosheiff R, Jammal M. Have New Plate Designs Reduced the Rate of Hardware Removal Following Midshaft Clavicle Fracture Fixation?. Journal of Clinical Medicine. 2025;14(18):6351. doi:10.3390/jcm14186351

BibTeX
@article{Oulianski2025,
  author = {Oulianski, Maria and Weil, Yoram and Ben Yehuda, Omer and Mosheiff, Rami and Jammal, Mahmoud},
  title = {Have New Plate Designs Reduced the Rate of Hardware Removal Following Midshaft Clavicle Fracture Fixation?},
  journal = {Journal of Clinical Medicine},
  year = {2025},
  volume = {14},
  number = {18},
  pages = {6351},
  doi = {10.3390/jcm14186351}
}
Kostenlos starten →