EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Impact of Transcatheter Edge-to-Edge Repair on Tricuspid Annular Remodeling in Patients with Tricuspid Regurgitation

Maddalena Widmann iD, Roberto Nerla, Fausto Castriota, Andrea Fisicaro, Valeria Maria De Luca iD, Gabriele Pesarini, Flavio Luciano Ribichini iD, Angelo Squeri iD

Journal of Clinical Medicine · 07.08.2025 · 14 (15) · 5606

DOI: 10.3390/jcm14155606 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 07.08.2025. Verfasst von Maddalena Widmann und 7 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiology, Department of Medicine, University of Verona, 37134 Verona, Italy. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

In recent years, multiple transcatheter devices have been developed for tricuspid valve intervention. The aim of this study was to evaluate acute tricuspid annular remodeling following percutaneous leaflet repair using a leaflet approximation device for the reduction of tricuspid regurgitation (TR).

Methods

This retrospective cohort study included 26 consecutive patients treated at two centers. Tricuspid annular geometry was assessed using three-dimensional transesophageal echocardiography during the procedure.

Results

The mean age of the cohort was 79.3 years, and 88.5% were female. All patients had severe or greater TR pre-procedure, mostly due to annular dilation. The procedure was successful in all cases, with at least a one-grade reduction in TR observed prior to hospital discharge. Significant reductions were observed in the mean septal-lateral diameter (4.09 ± 0.44 cm vs. 3.54 ± 0.53 cm, p < 0.0001), mean major diameter (4.65 ± 0.63 cm vs. 4.28 ± 0.65 cm, p = 0.0002), planimetric area (14.00 ± 2.91 cm2 vs. 11.25 ± 2.91 cm2, p < 0.0001), and perimeter (13.62 ± 1.43 cm vs. 12.42 ± 1.62 cm, p < 0.0001) of the tricuspid annulus.

Conclusions

In this small real-world cohort, transcatheter edge-to-edge repair was found to be both effective and safe. The use of a leaflet approximation device not only reduced TR severity but also led to significant reductions in annular dimensions. To our knowledge, this study provides additional evidence of acute tricuspid annulus remodeling following edge-to-edge repair, which may have significant therapeutic implications.

Schlagwörter

Stichwörter der Autor:innen

edge-to-edge repairtransoesophageal echocardiographytricuspid annulustricuspid regurgitation

Autor:innen und Institutionen

  • Division of Cardiology, Department of Medicine, University of Verona, 37134 Verona, Italy.
  • Cardiology Unit, Maria Cecilia Hospital GVM Care and Research, 48033 Cotignola, Italy.

ORCID-Profile: Maddalena Widmann, Valeria Maria De Luca, Flavio Luciano Ribichini, Angelo Squeri

Zitieren

APA

Widmann, M., Nerla, R., Castriota, F., Fisicaro, A., De Luca, V. M., Pesarini, G., Ribichini, F. L., & Squeri, A. (2025). Impact of Transcatheter Edge-to-Edge Repair on Tricuspid Annular Remodeling in Patients with Tricuspid Regurgitation. Journal of Clinical Medicine, 14(15), 5606. https://doi.org/10.3390/jcm14155606

Vancouver

Widmann M, Nerla R, Castriota F, Fisicaro A, De Luca VM, Pesarini G, et al. Impact of Transcatheter Edge-to-Edge Repair on Tricuspid Annular Remodeling in Patients with Tricuspid Regurgitation. Journal of Clinical Medicine. 2025;14(15):5606. doi:10.3390/jcm14155606

BibTeX
@article{Widmann2025,
  author = {Widmann, Maddalena and Nerla, Roberto and Castriota, Fausto and Fisicaro, Andrea and De Luca, Valeria Maria and Pesarini, Gabriele and Ribichini, Flavio Luciano and Squeri, Angelo},
  title = {Impact of Transcatheter Edge-to-Edge Repair on Tricuspid Annular Remodeling in Patients with Tricuspid Regurgitation},
  journal = {Journal of Clinical Medicine},
  year = {2025},
  volume = {14},
  number = {15},
  pages = {5606},
  doi = {10.3390/jcm14155606}
}
Kostenlos starten →