Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 26.06.2025. Verfasst von Karina Szczypiór-Piasecka und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Rehabilitation of the Musculoskeletal System, Pomeranian Medical University, 1 Unii Lubelskiej Street, 71-252 Szczecin, Poland. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background/Objectives: Gait abnormalities in advanced knee osteoarthritis (KOA) are characterized by decreased stride length, walking speed, and cadence. Total knee arthroplasty (TKA) is intended to improve temporal–spatial gait parameters; however, the extent and timing of functional recovery remain under investigation. To assess changes in stride length, walking speed, and cadence following TKA in short- and long-term perspectives, and to compare outcomes with a non-operated KOA cohort.
Methods
A prospective observational study was conducted involving 46 patients with unilateral KOA (grades III–IV, Kellgren–Lawrence scale) who underwent cemented TKA via a medial parapatellar approach. Group I (n = 34) was assessed one day prior to surgery and six weeks postoperatively. Group II (n = 12), a follow-up subset, was reassessed 1.5 years postoperatively. Group III (n = 34) served as a non-operated control group, assessed only preoperatively. Temporal–spatial gait parameters were evaluated under standardized conditions using a two-dimensional video analysis (Kinovea® software version 0.8.27). Stride length (m) and walking speed (m/s) were assessed during continuous walking along a 15 m corridor, with at least three valid gait cycles averaged per trial. Cadence (steps/min) was determined during a one-minute walk and verified frame-by-frame. No structured outpatient physiotherapy was provided; all patients followed a standardized in-hospital rehabilitation protocol.
Results
In Group I, the mean stride length increased from 0.40 ± 0.10 m to 0.42 ± 0.10 m (p = 0.247), walking speed improved from 0.41 ± 0.027 m/s to 0.47 ± 0.022 m/s (p = 0.063), and cadence increased significantly from 72.9 ± 7.8 to 77.1 ± 8.6 steps/min (p = 0.044). In Group II, the mean stride length rose from 0.39 ± 0.10 m to 0.52 ± 0.09 m (p < 0.001), walking speed improved from 0.44 ± 0.02 m/s to 0.69 ± 0.01 m/s (p < 0.001), and cadence increased from 73.7 ± 8.8 to 103.6 ± 7.4 steps/min (p < 0.001). Compared to the control group (Group III: stride length 0.42 ± 0.09 m; walking speed 0.41 ± 0.02 m/s; cadence 73.9 ± 7.9 steps/min), Group II demonstrated superior values across all parameters (p < 0.001 for each comparison). No significant correlations were observed between BMI and gait outcomes.
Conclusions
Total knee arthroplasty resulted in progressive improvement in temporal–spatial gait parameters. While early postoperative gains were limited, substantial functional restoration was observed at long-term follow-up, emphasizing the importance of extended recovery monitoring in post-TKA evaluation.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Rehabilitation of the Musculoskeletal System, Pomeranian Medical University, 1 Unii Lubelskiej Street, 71-252 Szczecin, Poland.
- Student Research Group for Orthopedic Rehabilitation and Manual Therapy at the Department of Orthopedics, Traumatology and Musculoskeletal Oncology, Pomeranian Medical University, 1 Unii Lubelskiej Street, 71-252 Szczec…
- Autonomous Knee Surgery Unit, Pomeranian Medical University, 1 Unii Lubelskiej Street, 71-252 Szczecin, Poland.
Zitieren
APA
Szczypiór-Piasecka, K., Adamczewska, P., Kołodziej, Ł., & Ziętek, P. (2025). The Temporal–Spatial Parameters of Gait After Total Knee Arthroplasty. Journal of Clinical Medicine, 14(13), 4548. https://doi.org/10.3390/jcm14134548
Vancouver
Szczypiór-Piasecka K, Adamczewska P, Kołodziej Ł, Ziętek P. The Temporal–Spatial Parameters of Gait After Total Knee Arthroplasty. Journal of Clinical Medicine. 2025;14(13):4548. doi:10.3390/jcm14134548
BibTeX
@article{SzczypirPiasecka2025,
author = {Szczypiór-Piasecka, Karina and Adamczewska, Paulina and Kołodziej, Łukasz and Ziętek, Paweł},
title = {The Temporal–Spatial Parameters of Gait After Total Knee Arthroplasty},
journal = {Journal of Clinical Medicine},
year = {2025},
volume = {14},
number = {13},
pages = {4548},
doi = {10.3390/jcm14134548}
}
EUVIMED