EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Evaluation of a Simple and Accurate Method for Intraocular Lens Constant Optimization Using Linear Interpolation

Sumitaka Miyamoto iD, Kazutaka Kamiya

Journal of Clinical Medicine · 26.06.2025 · 14 (13) · 4543

DOI: 10.3390/jcm14134543 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 26.06.2025. Verfasst von Sumitaka Miyamoto und 1 weiteren Autor:innen. Beteiligte Einrichtung: Aira Miyamoto Eye Clinic, Aira 8995213, Japan. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

We devised a simple and practical method for optimizing intraocular lens (IOL) constants using linear interpolation, based on the IOL power calculation study protocol proposed by Hoffer et al., and evaluated its effectiveness.

Methods

This retrospective study included 188 eyes from 188 Japanese patients who underwent cataract surgery with the implantation of CNA0T0 (Alcon) between June 2022 and September 2024. Preoperative biometric data were obtained using ARGOS (Alcon) and OA-2000 (Tomey). Predicted refractions were calculated using the European Society of Cataract and Refractive Surgeons’ (ESCRS) IOL Web Calculator with the EVO, Hill-RBF 3.0 (Hill), and Kane formulas, using both A-constants of 119.1 and 119.33. The mean prediction error (MPE) was calculated as the difference between the predicted and postoperative spherical equivalent at 3 months. Linear interpolation was applied to the paired results to derive optimized A-constants yielding MPE = 0 and to correct each case’s predicted refraction values (“corrected values”). Additionally, predicted refractions were recalculated using the optimized A-constants with the ESCRS IOL Web Calculator to obtain “actual values”. Both corrected and actual values achieved an MPE of 0 and were compared using the Friedman test and Cochran’s Q test.

Results

The optimized A-constants for ARGOS were 119.540 (EVO), 119.733 (Hill), and 119.563 (Kane); for OA-2000, they were 119.388, 119.532, and 119.417, respectively. No significant differences were found between corrected and actual values under any condition.

Conclusions

This method is simple, accurate, and applicable to new IOLs, devices, and formulas, with potential to improve the precision of clinical IOL power calculations.

Schlagwörter

Stichwörter der Autor:innen

ARGOSEVOHill-RBFKaneLinear interpolationOA-2000intraocular lens constant optimizationintraocular lens power calculation

Autor:innen und Institutionen

  • Aira Miyamoto Eye Clinic, Aira 8995213, Japan.
  • School of Rehabilitation Sciences, Showa Medical University, Yokohama 2268555, Japan.

ORCID-Profile: Sumitaka Miyamoto

Zitieren

APA

Miyamoto, S., & Kamiya, K. (2025). Evaluation of a Simple and Accurate Method for Intraocular Lens Constant Optimization Using Linear Interpolation. Journal of Clinical Medicine, 14(13), 4543. https://doi.org/10.3390/jcm14134543

Vancouver

Miyamoto S, Kamiya K. Evaluation of a Simple and Accurate Method for Intraocular Lens Constant Optimization Using Linear Interpolation. Journal of Clinical Medicine. 2025;14(13):4543. doi:10.3390/jcm14134543

BibTeX
@article{Miyamoto2025,
  author = {Miyamoto, Sumitaka and Kamiya, Kazutaka},
  title = {Evaluation of a Simple and Accurate Method for Intraocular Lens Constant Optimization Using Linear Interpolation},
  journal = {Journal of Clinical Medicine},
  year = {2025},
  volume = {14},
  number = {13},
  pages = {4543},
  doi = {10.3390/jcm14134543}
}
Kostenlos starten →