PREDICT sagte VAP bei beatmeten Intensivpatient:innen frühzeitig anhand von Vitalzeichen voraus. Die AUPRC lag bei 96,0 %, 94,1 % und 94,7 % für 6, 12 und 24 h vor VAP-Beginn.
Fragestellung
Kann ein Deep-Learning-Algorithmus auf Basis von Vitalzeichen eine VAP frühzeitig vorhersagen?
Methode
Retrospektive Kohortenstudie mit MIMIC-IV-Daten von ICU-Patient:innen, die mindestens 48 h beatmet waren; Training eines LSTM-Modells mit 5 Vitalzeichen in 24-h-Zeitfenstern; Vergleich mit klassischen ML-Modellen.
Ergebnisse
AUPRC 96,0 %, 94,1 % und 94,7 % für 6, 12 und 24 h vor VAP-Beginn. Sensitivität und positive prädiktive Werte lagen über 85 % in allen Zeitfenstern; RR, SpO2 und Temperatur waren wichtige Merkmale.
Schlussfolgerung der Autor:innen
PREDICT ist das erste speziell für die frühe VAP-Vorhersage auf Intensivstationen entwickelte Deep-Learning-Modell und könnte die klinische Entscheidung sowie den Antibiotikaeinsatz unterstützen.
Kernaussagen
- AUPRC: 96,0 %, 94,1 % und 94,7 %
- Sensitivität und positive prädiktive Werte >85 %
- Atemfrequenz, SpO2 und Temperatur waren zentral
Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.
Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 13.05.2025. Verfasst von Geoffray Agard und 9 weiteren Autor:innen. Beteiligte Einrichtung: Service de Médecine Intensive-Réanimation, AP-HM, Hôpital Nord, 13015 Marseille, France. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Themen: Pneumonieprophylaxe, Intensivpflege
Abstract (Originalsprache)
Background
Ventilator-associated pneumonia (VAP) is a common and serious ICU complication, affecting up to 40% of mechanically ventilated patients. The diagnosis of VAP currently relies on retrospective clinical, radiological, and microbiological criteria, which often delays targeted treatment and promotes the overuse of broad-spectrum antibiotics. The early prediction of VAP is crucial to improve outcomes and guide antimicrobial use related to this disease. This study aimed to develop and validate PREDICT (Pneumonia Risk Evaluation and Diagnostic Intelligence via Computational Technology), a deep learning algorithm for early VAP prediction that is based solely on vital signs.
Methods
We conducted a retrospective cohort study using the MIMIC-IV database, which includes ICU patients who were ventilated for at least 48 h. Five vital signs (respiratory rate, SpO2, heart rate, temperature, and mean arterial pressure) were structured into 24 h temporal windows. The PREDICT model, based on a long short-term memory neural network, was trained to predict the onset of VAP 6, 12, and 24 h in the future. Its performance was compared to that of conventional machine learning models (random forest, XGBoost, logistic regression) using their AUPRC, sensitivity, specificity, and predictive values.
Results
PREDICT achieved high predictive accuracy with AUPRC values of 96.0%, 94.1%, and 94.7% at 6, 12, and 24 h before the onset of VAP, respectively. Its sensitivity and positive predictive values exceeded 85% across all horizons. Traditional ML models showed a drop in performance over longer timeframes. Analysis of the model’s explainability highlighted the respiratory rate, SpO2, and temperature as key predictive features.
Conclusions
PREDICT is the first deep learning model specifically designed for early VAP prediction in ICUs. It represents a promising tool for timely clinical decision-making and improved antibiotic stewardship.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Service de Médecine Intensive-Réanimation, AP-HM, Hôpital Nord, 13015 Marseille, France.
- Faculté de Médecine, Aix-Marseille Université, Centre d'Etudes et de Recherches sur les Services de Santé et Qualité de vie (CERESS) EA 3279, 13005 Marseille, France.
- Laboratoire d'Informatique et Système (LIS) UMR 7020 CNRS/AMU/UTLN, Aix Marseille Université, Campus de Saint Jérôme, Bat. Polytech, 13288 Marseille, France.
- Département d'Information Médicale, AP-HM, Hôpital de la Conception, 13005 Marseille, France.
ORCID-Profile: Geoffray Agard, Christophe Guervilly, Damien Barrau, Laurent Boyer
Zitieren
APA
Agard, G., Roman, C., Guervilly, C., Forel, J. M., Orléans, V., Barrau, D., Auquier, P., Ouladsine, M., Boyer, L., & Hraiech, S. (2025). An Innovative Deep Learning Approach for Ventilator-Associated Pneumonia (VAP) Prediction in Intensive Care Units—Pneumonia Risk Evaluation and Diagnostic Intelligence via Computational Technology (PREDICT). Journal of Clinical Medicine, 14(10), 3380. https://doi.org/10.3390/jcm14103380
Vancouver
Agard G, Roman C, Guervilly C, Forel JM, Orléans V, Barrau D, et al. An Innovative Deep Learning Approach for Ventilator-Associated Pneumonia (VAP) Prediction in Intensive Care Units—Pneumonia Risk Evaluation and Diagnostic Intelligence via Computational Technology (PREDICT). Journal of Clinical Medicine. 2025;14(10):3380. doi:10.3390/jcm14103380
BibTeX
@article{Agard2025,
author = {Agard, Geoffray and Roman, Christophe and Guervilly, Christophe and Forel, Jean-Marie and Orléans, Véronica and Barrau, Damien and Auquier, Pascal and Ouladsine, Mustapha and Boyer, Laurent and Hraiech, Sami},
title = {An Innovative Deep Learning Approach for Ventilator-Associated Pneumonia (VAP) Prediction in Intensive Care Units—Pneumonia Risk Evaluation and Diagnostic Intelligence via Computational Technology (PREDICT)},
journal = {Journal of Clinical Medicine},
year = {2025},
volume = {14},
number = {10},
pages = {3380},
doi = {10.3390/jcm14103380}
}
EUVIMED