EUVIMEDEUVIMED entdecken
ÜbersichtsarbeitSystematische ÜbersichtOpen Access · CC BY 4.0

Systematic Review of Accuracy Differences in NIPT Methods for Common Aneuploidy Screening

Tamas Marton iD, Zsófia R Erdélyi, Minori Takai iD, Balázs Mészáros, Dorina Supák, Nándor Ács, Zoltán Kukor, Zoltan Herold iD, Beata Hargitai, Sándor Valent iD

Journal of Clinical Medicine · 18.04.2025 · 14 (8) · 2813

DOI: 10.3390/jcm14082813 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Journal of Clinical Medicine, online erschienen am 18.04.2025. Verfasst von Tamas Marton und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Obstetrics and Gynecology, Semmelweis University, 1082 Budapest, Hungary. Die Arbeit wurde bisher 29-mal zitiert (Crossref) und nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Hungarian Ministry for Culture and Innovation from the source of the National Research, Development and Innovation Fund.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Objectives: Non-invasive prenatal testing (NIPT) has become a widely used method for screening common fetal aneuploidies due to its high sensitivity and specificity compared to traditional screening methods. With various NIPT technologies available, such as whole-genome sequencing (WGS), single nucleotide polymorphisms (SNPs), microarray, and rolling circle amplification (RCA), understanding the accuracy and reliability of each method is critical for clinical decision-making. However, comprehensive evaluations comparing the performance of these NIPT methods, especially in terms of predictive values for trisomy detection, remain limited. A systematic review of the difference in accuracy of the different NIPT methods used for common aneuploidy screening.

Methods

A systematic review of former clinical studies using different NIPT methods, such as whole-genome sequencing (WGS), a targeted method of single nucleotide polymorphisms (SNPs), microarray and rolling circle amplification (RCA). We collected data from the PubMed, Embase, Web of Science, Scopus, clinicaltrials.gov, and Cochrane library from the last 20 years, between 2003 January and 2023 October, without any language, search filter or publication type restrictions.

Results

Two authors selected twenty articles including twenty-one studies to perform the systematic review. In these studies, altogether 92,164 pregnant women were tested by genomics-based non-invasive prenatal testing (NIPT). We extracted data on true positive, false positive, false negative, and true negative values from each study, and calculated sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) from them. We collected data regarding trisomy 21 (T21), trisomy 18 (T18) and trisomy 13 (T13) detection from all studies.

Conclusions

As a conclusion, for the detection of common fetal trisomies, different methods of NIPT perform similarly in terms of clinical sensitivity, specificity and NPV. However, the tests utilizing SNP and RCA had lower PPV values than other NIPT methods. Our research indicates all NIPT methods showed greater sensitivity for the detection of T21, above 97%, than traditional screening tests. For T18 detection, the targeted method with the microarray had a lower sensitivity compared to other tests. The SNP and the microarray-based test had high PPV, whilst the other tests, utilizing WGS, and the test with RCA had quite low PPV. Regarding T13 detection, all of the tests performed similarly in terms of clinical sensitivity, specificity, PPV, and NPV (with one exception—one of the tests using WGS had lower PPV). According to these results, there was no significant difference between the methods of NIPT, such as WGS, SNPs, microarray, and RCA, used to detect common trisomies, but the variation in PPV underlines the importance of invasive tests to derive positive NIPT results. We suggest that NIPT combined with US screening for structural abnormalities could further improve the utility of the non-invasive tests in pregnancy. This is the first independent systematic review into the efficacy of the different NIPT methods.

Schlagwörter

Stichwörter der Autor:innen

NIPTcfDNAcommon trisomy screeningnon-invasive prenatal testingprenatal diagnosissocioeconomical cost

Autor:innen und Institutionen

  • Department of Obstetrics and Gynecology, Semmelweis University, 1082 Budapest, Hungary.
  • Institute of Biochemistry and Molecular Biology, Department of Molecular Biology, Semmelweis University, 1094 Budapest, Hungary.
  • Division of Oncology, Department of Internal Medicine and Oncology, Semmelweis University, 1083 Budapest, Hungary.

ORCID-Profile: Tamas Marton, Minori Takai, Zoltan Herold, Sándor Valent

Förderung

  • Hungarian Ministry for Culture and Innovation from the source of the National Research, Development and Innovation Fund

Zitieren

APA

Marton, T., Erdélyi, Z. R., Takai, M., Mészáros, B., Supák, D., Ács, N., Kukor, Z., Herold, Z., Hargitai, B., & Valent, S. (2025). Systematic Review of Accuracy Differences in NIPT Methods for Common Aneuploidy Screening. Journal of Clinical Medicine, 14(8), 2813. https://doi.org/10.3390/jcm14082813

Vancouver

Marton T, Erdélyi ZR, Takai M, Mészáros B, Supák D, Ács N, et al. Systematic Review of Accuracy Differences in NIPT Methods for Common Aneuploidy Screening. Journal of Clinical Medicine. 2025;14(8):2813. doi:10.3390/jcm14082813

BibTeX
@article{Marton2025,
  author = {Marton, Tamas and Erdélyi, Zsófia R and Takai, Minori and Mészáros, Balázs and Supák, Dorina and Ács, Nándor and Kukor, Zoltán and Herold, Zoltan and Hargitai, Beata and Valent, Sándor},
  title = {Systematic Review of Accuracy Differences in NIPT Methods for Common Aneuploidy Screening},
  journal = {Journal of Clinical Medicine},
  year = {2025},
  volume = {14},
  number = {8},
  pages = {2813},
  doi = {10.3390/jcm14082813}
}
Kostenlos starten →