The Distribution of Ocular Normative Parameters in a Spanish School Population
Journal of Clinical Medicine · 07.04.2025 · 14 (7) · 2507
DOI: 10.3390/jcm14072507 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 07.04.2025. Verfasst von Rut González-Jiménez und 5 weiteren Autor:innen. Beteiligte Einrichtung: Optometry and Vision Department, Faculty of Optics and Optometry, Complutense University of Madrid, 28037 Madrid, Spain. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background/Objectives: The prevalence of myopia is increasing globally, including in Spain. The early detection of ocular biometric parameters associated with myopia development is crucial for implementing control strategies. This study aims to describe the normative biometric values in a Spanish school-aged population and compare them with previously established reference data.
Methods
A cross-sectional, observational, and analytical study was conducted on 558 students aged 6 to 12 years from the Educare Valdefuentes School in Madrid. Ocular biometric parameters, including axial length (AL), corneal curvature (CR), anterior chamber depth (ACD), crystalline lens thickness (LT), corneal thickness (CCT), and posterior vitreous depth (PVD), were measured using IOLMaster 700. The axial length/corneal radius (AL/CR) ratio was calculated. Percentile growth curves were generated, and the results were statistically analyzed using IBM SPSS 29.
Results
AL significantly increased with age (p < 0.001), and boys had longer AL than girls. The AL/CR ratio showed a moderate correlation with myopia risk (ρ = 0.647, p < 0.001). Compared to previous European studies, no significant differences were found, except for minor variations in AL and CR.
Conclusions
These percentile-based biometric values provide a useful reference for monitoring ocular growth and assessing myopia risk in Spanish children. The AL/CR ratio remains a strong predictor of myopia development, supporting its role in early detection strategies.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Optometry and Vision Department, Faculty of Optics and Optometry, Complutense University of Madrid, 28037 Madrid, Spain.
- Hospital Doce de Octubre Research Institute (i+12), 28041 Madrid, Spain.
- San Carlos Clinical Hospital, 28040 Madrid, Spain.
- Instituto Investigaciones Oftalmologicas Ramos Castroviejo, Facultad de Medicina, Complutense University of Madrid, 28037 Madrid, Spain.
ORCID-Profile: F Javier Povedano-Montero, Ricardo Bernárdez-Vilaboa, Rosario Gomez-de-Liano, Noemí Guemes-Villahoz, Juan E Cedrún-Sánchez
Zitieren
APA
González-Jiménez, R., Povedano-Montero, F. J., Bernárdez-Vilaboa, R., Gomez-de-Liano, R., Guemes-Villahoz, N., & Cedrún-Sánchez, J. E. (2025). The Distribution of Ocular Normative Parameters in a Spanish School Population. Journal of Clinical Medicine, 14(7), 2507. https://doi.org/10.3390/jcm14072507
Vancouver
González-Jiménez R, Povedano-Montero FJ, Bernárdez-Vilaboa R, Gomez-de-Liano R, Guemes-Villahoz N, Cedrún-Sánchez JE. The Distribution of Ocular Normative Parameters in a Spanish School Population. Journal of Clinical Medicine. 2025;14(7):2507. doi:10.3390/jcm14072507
BibTeX
@article{GonzlezJimnez2025,
author = {González-Jiménez, Rut and Povedano-Montero, F Javier and Bernárdez-Vilaboa, Ricardo and Gomez-de-Liano, Rosario and Guemes-Villahoz, Noemí and Cedrún-Sánchez, Juan E},
title = {The Distribution of Ocular Normative Parameters in a Spanish School Population},
journal = {Journal of Clinical Medicine},
year = {2025},
volume = {14},
number = {7},
pages = {2507},
doi = {10.3390/jcm14072507}
}
EUVIMED