Biofilm Growth on Different Materials Used in Contemporary Femoral Head Prosthesis: An In Vitro Study
Journal of Clinical Medicine · 04.03.2025 · 14 (5) · 1722
DOI: 10.3390/jcm14051722 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 04.03.2025. Verfasst von Yonggyun Moon und 5 weiteren Autor:innen. Beteiligte Einrichtung: College of Medicine, Chosun University, Gwangju 61452, Republic of Korea. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Research Foundation of Korea, Chosun University Hospital.
Abstract (Originalsprache)
Background/Objectives: Periprosthetic joint infection (PJI) primarily results from bacterial biofilms adhering to prosthetic surfaces, making treatment challenging without prosthesis removal. This in vitro study aims to investigate whether the materials used in contemporary femoral head prosthesis influences bacterial biofilm development.
Methods
Femoral head prostheses made of three different materials—cobalt–chrome, oxinium, and ceramic—were inoculated with either Staphylococcus aureus or Pseudomonas aeruginosa in separate experiments, with each pathogen tested independently. The samples were cultured under shaking conditions at 37 °C for 96 h to promote biofilm formation. Scanning electron microscopy (SEM) was used to confirm the presence of biofilms, and adherent biofilms were quantified by counting colony-forming units (CFUs) after sonication. Additionally, crystal violet staining was performed to assess biofilm distribution on the femoral head surfaces. Statistical analyses compared CFU counts across the different materials.
Results
The mean CFU counts for S. aureus were 7.6 × 105 ± 9.7 × 104 for cobalt–chrome, 6.9 × 105 ± 3.6 × 105 for oxinium, and 1.1 × 106 ± 3.0 × 105 for ceramic femoral head prostheses. For P. aeruginosa, the CFU counts were 2.3 × 106 ± 7.2 × 105, 3.7 × 106 ± 2.5 × 106, and 2.2 × 106 ± 8.9 × 105, respectively. Regardless of the bacterial strain, differences among the three materials were within one log range, and no statistical significance was observed. While biofilms were confirmed using SEM, limited adherence was observed on the bearing surface, with the biofilm predominantly localized in the taper hole.
Conclusions
The findings suggest that the material used in contemporary femoral head prostheses has minimal impact on bacterial biofilm formation. Surgeons’ choice of femoral head prosthesis material should base their material selection on factors other than PJI prevention.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- College of Medicine, Chosun University, Gwangju 61452, Republic of Korea.
- Department of Orthopedic Surgery, Chosun University Hospital, Gwangju 61453, Republic of Korea.
ORCID-Profile: Yonggyun Moon, Hyoungtae Kim, Suenghwan Jo
Förderung
- National Research Foundation of Korea
- Chosun University Hospital
Zitieren
APA
Moon, Y., Hong, J., Choi, S., Kim, H., Sohn, H. M., & Jo, S. (2025). Biofilm Growth on Different Materials Used in Contemporary Femoral Head Prosthesis: An In Vitro Study. Journal of Clinical Medicine, 14(5), 1722. https://doi.org/10.3390/jcm14051722
Vancouver
Moon Y, Hong J, Choi S, Kim H, Sohn HM, Jo S. Biofilm Growth on Different Materials Used in Contemporary Femoral Head Prosthesis: An In Vitro Study. Journal of Clinical Medicine. 2025;14(5):1722. doi:10.3390/jcm14051722
BibTeX
@article{Moon2025,
author = {Moon, Yonggyun and Hong, Jaeyoung and Choi, Sookyung and Kim, Hyoungtae and Sohn, Hong Moon and Jo, Suenghwan},
title = {Biofilm Growth on Different Materials Used in Contemporary Femoral Head Prosthesis: An In Vitro Study},
journal = {Journal of Clinical Medicine},
year = {2025},
volume = {14},
number = {5},
pages = {1722},
doi = {10.3390/jcm14051722}
}
EUVIMED