EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Computed Tomography Doses Calculation: Do We Really Need a New Dose Assessment Tool?

Arkadiusz Szarmach, Dominika Sabiniewicz-Ziajka, Małgorzata Grzywińska iD, Paweł Gać iD, Maciej Piskunowicz, Magdalena Wszędybył-Winklewska iD

Journal of Clinical Medicine · 18.02.2025 · 14 (4) · 1348

DOI: 10.3390/jcm14041348 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 18.02.2025. Verfasst von Arkadiusz Szarmach und 5 weiteren Autor:innen. Beteiligte Einrichtung: 2nd Department of Radiology, Medical University of Gdansk, 80-210 Gdansk, Poland. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Objectives: The increasing use of computed tomography (CT) scans significantly contributes to population exposure to ionizing radiation. Traditional dose metrics, such as dose–length product (DLP) and effective dose (ED), lack precision in reflecting individual radiation exposure. This study introduces a novel parameters such as size-specific effective dose (EDss) and the size-specific dose–length product (DLPss), to improve patient-specific dose estimation. The aim of this study is to enhance dose calculation accuracy, optimize CT protocols, and guide the development of next-generation CT technologies.

Methods

A retrospective analysis of 247 abdominal and pelvic CT scans (113 women, 134 men) was conducted. Anthropometric parameters, including body mass index (BMI), cross-sectional dimensions, and dose indices, were measured. EDss and DLPss were calculated using size-specific correction factors, and statistical correlations between these parameters were assessed.

Results

The mean BMI was 25.92 ± 5.34. DLPss values ranged from 261.63 to 1217.70 mGy·cm (mean: 627.83 ± 145.32) and were roughly 21% higher than traditional DLP values, with men showing slightly higher mean values than women. EDss values ranged from 6.65 to 15.45 mSv (mean: 9.42 ± 2.18 mSv), approximately 22% higher than traditional ED values, demonstrating improved individualization. Significant correlations were observed between BMI and effective diameter (r = 0.78), with stronger correlations in men (r = 0.85). The mean CTDIvol was 11.37 ± 3.50 mGy, and SSDE averaged 13.91 ± 2.39 mGy. Scan length reductions were observed in 53.8% of cases, with statistically significant differences by gender.

Conclusions

EDss and DLPss offer improved accuracy in radiation dose estimation, addressing the limitations of traditional methods. Their adoption into clinical protocols, supported by AI-driven automation, could optimize diagnostic safety and significantly reduce radiation risk for patients. Further multicenter studies and technological advancements are recommended to validate these metrics and facilitate their integration into daily practice.

Schlagwörter

Stichwörter der Autor:innen

computed tomographydose–length productradiation dose calculationsize-specific dose estimatesize-specific dose–length product

Autor:innen und Institutionen

  • 2nd Department of Radiology, Medical University of Gdansk, 80-210 Gdansk, Poland.
  • Neuroinformatics and Artificial Intelligence Laboratory, Department of Neurophysiology, Neuropsychology and Neuroinformatics, Medical University of Gdansk, 80-210 Gdansk, Poland.
  • Centre for Diagnostic Imaging, 4th Military Hospital, Weigla 5, 50-981 Wroclaw, Poland.
  • Department of Population Health, Division of Environmental Health and Occupational Medicine, Wroclaw Medical University, Mikulicza-Radeckiego 7, 50-368 Wroclaw, Poland.
  • 1st Department of Radiology, Medical University of Gdansk, 80-210 Gdansk, Poland.
  • Institute of Health Sciences, Pomeranian University in Slupsk, 76-200 Slupsk, Poland.

ORCID-Profile: Małgorzata Grzywińska, Paweł Gać, Magdalena Wszędybył-Winklewska

Zitieren

APA

Szarmach, A., Sabiniewicz-Ziajka, D., Grzywińska, M., Gać, P., Piskunowicz, M., & Wszędybył-Winklewska, M. (2025). Computed Tomography Doses Calculation: Do We Really Need a New Dose Assessment Tool?. Journal of Clinical Medicine, 14(4), 1348. https://doi.org/10.3390/jcm14041348

Vancouver

Szarmach A, Sabiniewicz-Ziajka D, Grzywińska M, Gać P, Piskunowicz M, Wszędybył-Winklewska M. Computed Tomography Doses Calculation: Do We Really Need a New Dose Assessment Tool?. Journal of Clinical Medicine. 2025;14(4):1348. doi:10.3390/jcm14041348

BibTeX
@article{Szarmach2025,
  author = {Szarmach, Arkadiusz and Sabiniewicz-Ziajka, Dominika and Grzywińska, Małgorzata and Gać, Paweł and Piskunowicz, Maciej and Wszędybył-Winklewska, Magdalena},
  title = {Computed Tomography Doses Calculation: Do We Really Need a New Dose Assessment Tool?},
  journal = {Journal of Clinical Medicine},
  year = {2025},
  volume = {14},
  number = {4},
  pages = {1348},
  doi = {10.3390/jcm14041348}
}
Kostenlos starten →