Vasa Previa: Prenatal Diagnosis and the Rationale Behind Using a 5 cm Distance from Internal Os
Journal of Clinical Medicine · 05.02.2025 · 14 (3) · 1009
DOI: 10.3390/jcm14031009 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Journal of Clinical Medicine, online erschienen am 05.02.2025. Verfasst von Claudio V Schenone und 7 weiteren Autor:innen. Beteiligte Einrichtung: Fetal Care and Surgery Center, Boston Children's Hospital, Harvard Medical School, Boston, MA 02215, USA. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 69 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
In pregnancies with vasa previa, prenatal diagnosis and pre-labor cesarean delivery are associated with significantly improved perinatal outcomes compared to undetected cases. However, a universally accepted ultrasonographic definition of vasa previa is lacking. Specifically, the distance from the cervical internal os beyond which vaginal delivery can be safely recommended remains to be determined. Field experts and recently published societal guidelines agree that a 2 cm cut-off is suboptimal, given that complete cervical dilation during labor risks unprotected fetal vessels within a 5 cm radius from the internal os. Thus, in the setting of a scarcity of evidence and case reports of perinatal death with unprotected fetal vessels beyond 2 cm from the internal os, a more conservative definition that includes unprotected fetal vessels located within 5 cm of the internal os is imperative to improve outcomes.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Fetal Care and Surgery Center, Boston Children's Hospital, Harvard Medical School, Boston, MA 02215, USA.
- Division of Maternal Fetal Medicine, Department of Obstetrics and Gynecology, Beth Israel Deaconess Medical Center, Boston, MA 02215, USA.
- Department of Obstetrics, Gynecology and Reproductive Sciences, Division of Fetal Intervention, UTHealth McGovern Medical School, Houston, TX 77030, USA.
- Department of Obstetrics and Gynecology, Keck School of Medicine, University of Southern California, Los Angeles, CA 90027, USA.
ORCID-Profile: Claudio V Schenone, Faezeh Aghajani, Ramesha Papanna
Zitieren
APA
Schenone, C. V., Aghajani, F., Javinani, A., Krispin, E., Oyelese, Y., Papanna, R., Chmait, R. H., & Shamshirsaz, A. A. (2025). Vasa Previa: Prenatal Diagnosis and the Rationale Behind Using a 5 cm Distance from Internal Os. Journal of Clinical Medicine, 14(3), 1009. https://doi.org/10.3390/jcm14031009
Vancouver
Schenone CV, Aghajani F, Javinani A, Krispin E, Oyelese Y, Papanna R, et al. Vasa Previa: Prenatal Diagnosis and the Rationale Behind Using a 5 cm Distance from Internal Os. Journal of Clinical Medicine. 2025;14(3):1009. doi:10.3390/jcm14031009
BibTeX
@article{Schenone2025,
author = {Schenone, Claudio V and Aghajani, Faezeh and Javinani, Ali and Krispin, Eyal and Oyelese, Yinka and Papanna, Ramesha and Chmait, Ramen H and Shamshirsaz, Alireza A},
title = {Vasa Previa: Prenatal Diagnosis and the Rationale Behind Using a 5 cm Distance from Internal Os},
journal = {Journal of Clinical Medicine},
year = {2025},
volume = {14},
number = {3},
pages = {1009},
doi = {10.3390/jcm14031009}
}
EUVIMED