EUVIMEDEUVIMED entdecken
ÜbersichtsarbeitSystematische ÜbersichtMetaanalyseOpen Access · CC BY 4.0

The Use of Highly Porous 3-D-Printed Titanium Acetabular Cups in Revision Total Hip Arthroplasty: A Systematic Review and Meta-Analysis

Peter Richard Almeida iD, Gavin J Macpherson, Philip Simpson, Paul Gaston, Nick D Clement iD

Journal of Clinical Medicine · 31.01.2025 · 14 (3) · 938

DOI: 10.3390/jcm14030938 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Journal of Clinical Medicine, online erschienen am 31.01.2025. Verfasst von Peter Richard Almeida und 4 weiteren Autor:innen. Beteiligte Einrichtung: Edinburgh Orthopaedics, Royal Infirmary of Edinburgh, Edinburgh EH16 4SA, UK. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Objectives: As the rate of revision total hip arthroplasty (THA) has risen, there has been a drive to improve the technology in the manufacturing of the implants used. One recent advance has been 3-D printing of trabecular titanium implants to improve implant stability and osteointegration. The aim of this study was to review the clinical and radiological outcomes of these acetabular implants in revision THA.

Methods

A manual search of the databases of the US National Library of medicine (PubMed/MEDLINE), Embase, and the Cochrane library was performed. The following keywords of “revision total hip arthroplasty” AND “acetabulum” AND “titanium” AND “porous” were utilised.

Results

In total, 106 abstracts were identified during manual search of databases. In total, 11 studies reporting 4 different implants, with a total of 597 operated joints in 585 patients were included in this review. There were 349 (59.7%) female patients, and the mean age per study ranged from 56.0 to 78.4 years. The all-cause survival rate was 95.52% (95% CI: 92.37–97.96) at a mean follow up of 3.8 years (95% CI: 2.6–5.1). The 40 cases that required re-operation included 17 (2.8%) for infection, 14 (2.3%) instability, 2 (0.3%) for shell migration and 5 (0.8%) for aseptic loosening. The most commonly used patient reported outcome measure was the Harris Hip Score with the mean post-operative score of 86.7 (95% CI: 84.3–89.1).

Conclusions

Trabecular titanium acetabular implants, when used in revision THA, resulted in excellent short- to mid-term outcomes with improved hip specific outcomes and a survivorship of 95.52% over the reported follow-up period. Future prospective studies evaluating long term outcomes are needed to make comparisons between more established solutions used in revision THA.

Schlagwörter

Stichwörter der Autor:innen

acetabulumadditive manufacturingrevision total hip arthroplastytitanium

Autor:innen und Institutionen

  • Edinburgh Orthopaedics, Royal Infirmary of Edinburgh, Edinburgh EH16 4SA, UK.
  • Department of Orthopaedics and Trauma, University of Edinburgh, Edinburgh EH8 9YL, UK.

ORCID-Profile: Peter Richard Almeida, Nick D Clement

Zitieren

APA

Almeida, P. R., Macpherson, G. J., Simpson, P., Gaston, P., & Clement, N. D. (2025). The Use of Highly Porous 3-D-Printed Titanium Acetabular Cups in Revision Total Hip Arthroplasty: A Systematic Review and Meta-Analysis. Journal of Clinical Medicine, 14(3), 938. https://doi.org/10.3390/jcm14030938

Vancouver

Almeida PR, Macpherson GJ, Simpson P, Gaston P, Clement ND. The Use of Highly Porous 3-D-Printed Titanium Acetabular Cups in Revision Total Hip Arthroplasty: A Systematic Review and Meta-Analysis. Journal of Clinical Medicine. 2025;14(3):938. doi:10.3390/jcm14030938

BibTeX
@article{Almeida2025,
  author = {Almeida, Peter Richard and Macpherson, Gavin J and Simpson, Philip and Gaston, Paul and Clement, Nick D},
  title = {The Use of Highly Porous 3-D-Printed Titanium Acetabular Cups in Revision Total Hip Arthroplasty: A Systematic Review and Meta-Analysis},
  journal = {Journal of Clinical Medicine},
  year = {2025},
  volume = {14},
  number = {3},
  pages = {938},
  doi = {10.3390/jcm14030938}
}
Kostenlos starten →