Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 16.01.2025. Verfasst von Isabelle M A van Gruting und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Obstetrics and Gynaecology, Croydon University Hospital, Croydon CR7 7YE, UK. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

The aim of this study is to validate a uniform method for measuring perineal descent which can be used for different imaging methods, to establish cut-off values for this measurement, and to assess diagnostic test accuracy (DTA) of imaging techniques using these cut-off values. Secondly, the study aims to correlate perineal descent to symptoms, signs and imaging findings in women with obstructed defaecation syndrome (ODS) to assess its clinical relevance.

Methods

Cross-sectional study of 131 women with symptoms of ODS. Symptoms and signs were assessed using validated methods. These women underwent evacuation proctography (EP), magnetic resonance imaging (MRI), transperineal ultrasound (TPUS) and endovaginal ultrasound (EVUS). Perineal descent was measured on EP and MRI as the position of anorectal junction (ARJ) with respect to the pubococcygeal line (PCL) at rest (i.e., static descent) and during evacuation (i.e., descent at Valsalva). Dynamic perineal descent was measured on all four imaging techniques as the difference between the position of the ARJ at rest and Valsalva. DTA of dynamic perineal descent was estimated using Latent Class Analysis in the absence of a reference standard.

Results

Interobserver agreement of dynamic perineal descent measurements was good for MRI and EVUS (ICC 0.86 and 0.85) and moderate for EP and TPUS (ICC 0.61 and 0.59). The systematic differences in measurements between imaging techniques show the need for individual cut-off values. New established cut-off values for dynamic descent are for EP 20 mm, MRI 35 mm, TPUS 15 mm and EVUS 15 mm. Sensitivity was moderate for EP (0.78) and MRI (0.74), fair for TPUS (0.65) and poor for EVUS (0.58). Specificity was similar for all imaging techniques (0.73–0.77). Static perineal descent correlated with symptoms of pelvic organ prolapse (POP) (r = 0.19), prolapse of all three compartments (r = 0.19–0.36), presence of levator ani muscle avulsion (p = 0.01) and increased hiatal area (r = 0.51). Dynamic perineal descent correlated with excessive straining (r = 0.24) and use of laxatives (r = 0.24). Classic symptoms of ODS (incomplete evacuation and digitation) did not correlate with perineal descent measurements. Static and dynamic perineal descent were associated with presence of rectocele, enterocele, intussusception, and absence of anismus.

Conclusions

Dynamic perineal descent is a reliable measurement that can be applied to different imaging techniques to allow standardisation. Static descent is more often present in women with POP and dynamic descent is more often present in women with constipation. Perineal descent does not correlate with typical symptoms of ODS. Specificity of TPUS and EVUS is comparable to EP and MRI, hence ultrasound could be used for the initial assessment of pelvic floor dysfunction.

Schlagwörter

Stichwörter der Autor:innen

diagnostic test accuracyobstructed defaecation syndromepelvic floor ultrasoundperineal descent

Autor:innen und Institutionen

  • Department of Obstetrics and Gynaecology, Croydon University Hospital, Croydon CR7 7YE, UK.
  • Department of Obstetrics and Gynaecology, Radboud University Medical Center, 6525 GA Nijmegen, The Netherlands.
  • Department of Radiology, Croydon University Hospital, Croydon CR7 7YE, UK.
  • Department of Radiology, University Hospitals of North Midlands NHS Trust, Stoke-on-Trent ST4 6QG, UK.
  • IQ Health Department, Radboud University Medical Center, 6525 GA Nijmegen, The Netherlands.
  • Department of Obstetrics and Gynaecology, Jeroen Bosch Ziekenhuis, 5223 GW Den Bosch, The Netherlands.

ORCID-Profile: Isabelle M A van Gruting, Kirsten Kluivers, Joanna IntHout, Kim W M van Delft, Abdul H Sultan

Zitieren

APA

van Gruting, I. M. A., Kluivers, K., Stankiewicz, A., IntHout, J., van Delft, K. W. M., Thakar, R., & Sultan, A. H. (2025). Evaluation of Perineal Descent Measurements on Pelvic Floor Imaging. Journal of Clinical Medicine, 14(2), 548. https://doi.org/10.3390/jcm14020548

Vancouver

van Gruting IMA, Kluivers K, Stankiewicz A, IntHout J, van Delft KWM, Thakar R, et al. Evaluation of Perineal Descent Measurements on Pelvic Floor Imaging. Journal of Clinical Medicine. 2025;14(2):548. doi:10.3390/jcm14020548

BibTeX
@article{vanGruting2025,
  author = {van Gruting, Isabelle M A and Kluivers, Kirsten and Stankiewicz, Aleksandra and IntHout, Joanna and van Delft, Kim W M and Thakar, Ranee and Sultan, Abdul H},
  title = {Evaluation of Perineal Descent Measurements on Pelvic Floor Imaging},
  journal = {Journal of Clinical Medicine},
  year = {2025},
  volume = {14},
  number = {2},
  pages = {548},
  doi = {10.3390/jcm14020548}
}
Kostenlos starten →