Comparative Accuracy of Stationary and Smartphone-Based Photogrammetry in Oral and Maxillofacial Surgery: A Clinical Study
Journal of Clinical Medicine · 07.11.2024 · 13 (22) · 6678
DOI: 10.3390/jcm13226678 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 07.11.2024. Verfasst von Lukas B Seifert und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oral, Cranio-Maxillofacial and Facial Plastic Surgery, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60528 Frankfurt am Main, Ger…. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Werner Siemens Foundation (MIRACLE project).
Abstract (Originalsprache)
Background
Three-dimensional facial scan technologies, such as stereophotogrammetry, are frequently used in oral and maxillofacial surgery, dentistry, and plastic surgery to assess patient outcomes and plan surgical procedures. Most facial scanners rely on stationary clinical systems, which provide high accuracy and reliability in generating 3D representations of the human face; however, they are cost-intensive and immobile. Recently, smartphone-based facial scan applications that use stereophotogrammetry have been developed. These applications are cost-effective and more accessible than existing stationary systems.
Methods
In this study, we compared the accuracy of three different smartphone applications—EM3D, Polycam, and ScandyPro—on an iPhone 14 Pro, which utilizes Apple’s LiDAR (Light Detection and Ranging) technology, to a stationary system by 3DMD, which is considered a gold standard in many studies.
Results
The applications included in the study have demonstrated the capability to perform accurately in clinical settings, with mean surface distances of 1.46 mm for EM3D, 1.66 mm for Polycam, and 1.61 mm for ScandyPro.
Conclusions
These results suggest that smartphone-based facial scan systems could be a viable alternative, particularly in resource-limited settings. However, further research and collaboration between academia and industry are necessary to fully integrate these technologies into clinical practice.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Oral, Cranio-Maxillofacial and Facial Plastic Surgery, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60528 Frankfurt am Main, Germany.
- Clinic of Oral and Cranio-Maxillofacial Surgery, University Hospital Basel, CH-4031 Basel, Switzerland.
- Medical Additive Manufacturing Research Group (Swiss MAM), Department of Biomedical Engineering, University of Basel, CH-4123 Allschwil, Switzerland.
ORCID-Profile: Florian M Thieringer
Förderung
- Werner Siemens Foundation (MIRACLE project)
Zitieren
APA
Seifert, L. B., Beyer, M., Czok, V., Aigner, A., Abazi, S., Thieringer, F. M., & Sader, R. (2024). Comparative Accuracy of Stationary and Smartphone-Based Photogrammetry in Oral and Maxillofacial Surgery: A Clinical Study. Journal of Clinical Medicine, 13(22), 6678. https://doi.org/10.3390/jcm13226678
Vancouver
Seifert LB, Beyer M, Czok V, Aigner A, Abazi S, Thieringer FM, et al. Comparative Accuracy of Stationary and Smartphone-Based Photogrammetry in Oral and Maxillofacial Surgery: A Clinical Study. Journal of Clinical Medicine. 2024;13(22):6678. doi:10.3390/jcm13226678
BibTeX
@article{Seifert2024,
author = {Seifert, Lukas B and Beyer, Michel and Czok, Vanessa and Aigner, Alexander and Abazi, Sead and Thieringer, Florian M and Sader, Robert},
title = {Comparative Accuracy of Stationary and Smartphone-Based Photogrammetry in Oral and Maxillofacial Surgery: A Clinical Study},
journal = {Journal of Clinical Medicine},
year = {2024},
volume = {13},
number = {22},
pages = {6678},
doi = {10.3390/jcm13226678}
}
EUVIMED