Comparison of the Clinical Evaluation of Digital Tooth Shade Determination Using an Intraoral Scanner with Proven Subjective and Objective Methods
Journal of Clinical Medicine · 06.11.2024 · 13 (22) · 6668
DOI: 10.3390/jcm13226668 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 06.11.2024. Verfasst von Nicolai Budde und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, Martin-Luther-University Halle-Wittenberg, Magdeburger Str. 16, 06112 Halle (Saale), Germany. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: SpectroShade Micro.
Abstract (Originalsprache)
Background/Objectives: Despite the increasing use of chromatic intraoral scanners, color determination is often performed visually, offering poor reliability and validity. In this study, we aimed to compare the reliability and validity of the tooth shade determination tool of an intraoral scanner (Trios3 Color) with that of two dental spectrophotometers (VITA Easyshade Advance 4.0 and SpectroShade Micro) and with visual determination using the VITA 3D-Master shade guide.
Methods
In vivo tooth shade determination was performed on 33 participants using positioning splints for the right central incisor. Repeated measurements assessed the reliability in determining the percentage agreement with VITA 3D-Master shades. VITA Easyshade measurements were used as reference values for validity. The metric value Delta E (ΔE) in the International Commission on Illumination L*a*b* color space was compared to the reference, with ΔE greater than 1 indicating visible differences and a maximum value of ΔE 6.8 being clinically acceptable.
Results
The reliabilities of VITA Easyshade, the intraoral scanner, and SpectroShade Micro were 75.8%, 87.9%, and 89.9%, respectively. The visual method had an agreement rate of 20.6%. Validity values, compared with the reference value, were ΔE 3.8 (clinically acceptable), 8.3, and 7.4 (the latter two both being clinically unacceptable) for the intraoral scanner, area-measuring device, and visual method, respectively.
Conclusions
The intraoral scanner is a reliable and valid tool for tooth shade determination and is superior to the visual method in both aspects.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Prosthodontics, Martin-Luther-University Halle-Wittenberg, Magdeburger Str. 16, 06112 Halle (Saale), Germany.
- Institute of Medical Epidemiology, Biometry and Computer Science, Martin-Luther-University Halle-Wittenberg, Magdeburger Str. 8, 06112 Halle (Saale), Germany.
ORCID-Profile: Nicolai Budde, Andreas Wienke, Ramona Schweyen
Förderung
- SpectroShade Micro
Zitieren
APA
Budde, N., Arnold, C., Wienke, A., & Schweyen, R. (2024). Comparison of the Clinical Evaluation of Digital Tooth Shade Determination Using an Intraoral Scanner with Proven Subjective and Objective Methods. Journal of Clinical Medicine, 13(22), 6668. https://doi.org/10.3390/jcm13226668
Vancouver
Budde N, Arnold C, Wienke A, Schweyen R. Comparison of the Clinical Evaluation of Digital Tooth Shade Determination Using an Intraoral Scanner with Proven Subjective and Objective Methods. Journal of Clinical Medicine. 2024;13(22):6668. doi:10.3390/jcm13226668
BibTeX
@article{Budde2024,
author = {Budde, Nicolai and Arnold, Christin and Wienke, Andreas and Schweyen, Ramona},
title = {Comparison of the Clinical Evaluation of Digital Tooth Shade Determination Using an Intraoral Scanner with Proven Subjective and Objective Methods},
journal = {Journal of Clinical Medicine},
year = {2024},
volume = {13},
number = {22},
pages = {6668},
doi = {10.3390/jcm13226668}
}
EUVIMED