Endovascular Embolization of Intracranial Aneurysms Using Target Tetra Detachable Coils: Angiographic and Clinical Results from a Single Center
Journal of Clinical Medicine · 21.08.2024 · 13 (16) · 4940
DOI: 10.3390/jcm13164940 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 21.08.2024. Verfasst von Wook Kim und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Republic of Korea. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background/Objectives: Target tetra detachable coils (TTDCs) aid in achieving effective framing during the coil embolization of small intracranial aneurysms by maintaining a tetrahedral conformation within the aneurysm sac. We aimed to report the initial experience of patients treated for intracranial aneurysms using TTDCs, with a specific focus on efficacy and safety.
Methods
We retrospectively reviewed the medical records of 41 patients who underwent the coil embolization of intracranial aneurysms sized ≤10 mm with TTDCs between April and May 2023. Post-procedural angiographic and clinical results were reviewed.
Results
Of the 46 aneurysms (45 unruptured and 1 ruptured), 33 (71.7%) were treated with the stent-assisted technique and 13 (28.3%) using the simple coil embolization technique. Post-procedural angiography showed complete occlusion in 41 aneurysms (89.1%), neck remnants in 1 (2.2%), and residual aneurysms in 4 (8.7%). The mean packing density was 34.7% (19.3–46.8%), with TTDC coil length comprising a mean of 88.5% of the total coil length. No major device- or procedure-related complications were observed. During the follow-up, 40 aneurysms (93.0%) demonstrated complete occlusion, while neck remnants were observed in 1 (2.3%), and residual aneurysms in 2 (4.7%). No cases of recanalization were observed.
Conclusions
The TTDC is a safe and effective device for the endovascular treatment of intracranial aneurysms. Follow-up studies are required to establish long-term results.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Republic of Korea.
- Department of Neurosurgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Republic of Korea.
ORCID-Profile: Wook Kim, Je Young Yeon, Pyoung Jeon
Zitieren
APA
Kim, W., Jee, T. K., Yeon, J. Y., Kim, K. H., Kim, J. S., & Jeon, P. (2024). Endovascular Embolization of Intracranial Aneurysms Using Target Tetra Detachable Coils: Angiographic and Clinical Results from a Single Center. Journal of Clinical Medicine, 13(16), 4940. https://doi.org/10.3390/jcm13164940
Vancouver
Kim W, Jee TK, Yeon JY, Kim KH, Kim JS, Jeon P. Endovascular Embolization of Intracranial Aneurysms Using Target Tetra Detachable Coils: Angiographic and Clinical Results from a Single Center. Journal of Clinical Medicine. 2024;13(16):4940. doi:10.3390/jcm13164940
BibTeX
@article{Kim2024,
author = {Kim, Wook and Jee, Tae Keun and Yeon, Je Young and Kim, Keon Ha and Kim, Jong-Soo and Jeon, Pyoung},
title = {Endovascular Embolization of Intracranial Aneurysms Using Target Tetra Detachable Coils: Angiographic and Clinical Results from a Single Center},
journal = {Journal of Clinical Medicine},
year = {2024},
volume = {13},
number = {16},
pages = {4940},
doi = {10.3390/jcm13164940}
}
EUVIMED