EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Influence of Cochlear Anatomy on Intraoperative Electrically Evoked Compound Action Potentials

Nawaf Fatani iD, Yassin Abdelsamad, Abdulrahman Alsanosi

Journal of Clinical Medicine · 12.08.2024 · 13 (16) · 4716

DOI: 10.3390/jcm13164716 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 12.08.2024. Verfasst von Nawaf Fatani und 2 weiteren Autor:innen. Beteiligte Einrichtung: King Abdullah Ear Specialist Center (KAESC), College of Medicine, King Saud University Medical City (KSUMC), King Saud University, Riyadh 11411, Saud…. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

The electrically evoked compound action potential (ECAP) is an objective measure to indirectly assess spiral ganglion neurons. The ECAP provides inputs about the prognoses of cochlear implant (CI) recipients. Several factors such as cochlear morphology can affect ECAP measurements. This study aims to investigate the variation effect of cochlear parameters on intraoperative ECAP thresholds.

Methods

This is a retrospective study on patients who underwent CI surgery with normal inner ear morphology at our center between 2017 and 2023. Cochlear anatomical parameters, including diameter (A value), width (B value), and height (H value), as well as cochlear duct length (CDL), were measured pre-operatively using OTOPLAN software (Version 3.0). Cochlear implant intraoperative objective measures were also collected. The correlation between the cochlear parameters and intraoperative objective measures was studied.

Results

A total of 45 patients underwent cochlear implantation. The mean age was 2.4 ± 0.9 years. The mean CDL and cochlear coverage values were 33.2 ± 2.0 mm and 76.0 ± 5.7%, respectively. The ECAP threshold increased toward basal electrodes, with ECAP values as follows: apical 13.1 ± 3.8; middle 14.3 ± 3.7; and basal 15.6 ± 4.8. Additionally, the A, B, and H values showed a positive correlation with ECAP thresholds in different cochlear regions. The B value showed a significant moderate correlation with ECAP thresholds in the middle and basal electrodes but not in the apical electrodes.

Conclusions

Cochlear anatomical parameters correlate with intraoperative ECAP thresholds. The B value showed a significant association with ECAP thresholds in the middle and basal electrodes. These findings could delineate the impact of the B value in CI and optimize electrode selection. Further research is required to study this correlation and its impact on postoperative outcomes.

Schlagwörter

Stichwörter der Autor:innen

cochlear duct lengthcochlear implantcochlear implantationevoked compound action potential

Autor:innen und Institutionen

  • King Abdullah Ear Specialist Center (KAESC), College of Medicine, King Saud University Medical City (KSUMC), King Saud University, Riyadh 11411, Saudi Arabia.
  • Research Department, MED-EL GmbH, Riyadh 12631, Saudi Arabia.

ORCID-Profile: Nawaf Fatani

Zitieren

APA

Fatani, N., Abdelsamad, Y., & Alsanosi, A. (2024). Influence of Cochlear Anatomy on Intraoperative Electrically Evoked Compound Action Potentials. Journal of Clinical Medicine, 13(16), 4716. https://doi.org/10.3390/jcm13164716

Vancouver

Fatani N, Abdelsamad Y, Alsanosi A. Influence of Cochlear Anatomy on Intraoperative Electrically Evoked Compound Action Potentials. Journal of Clinical Medicine. 2024;13(16):4716. doi:10.3390/jcm13164716

BibTeX
@article{Fatani2024,
  author = {Fatani, Nawaf and Abdelsamad, Yassin and Alsanosi, Abdulrahman},
  title = {Influence of Cochlear Anatomy on Intraoperative Electrically Evoked Compound Action Potentials},
  journal = {Journal of Clinical Medicine},
  year = {2024},
  volume = {13},
  number = {16},
  pages = {4716},
  doi = {10.3390/jcm13164716}
}
Kostenlos starten →