Endodontic Treatment Outcomes in Cone Beam Computed Tomography Images—Assessment of the Diagnostic Accuracy of AI
Journal of Clinical Medicine · 14.07.2024 · 13 (14) · 4116
DOI: 10.3390/jcm13144116 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 14.07.2024. Verfasst von Wojciech Kazimierczak und 6 weiteren Autor:innen. Beteiligte Einrichtung: Kazimierczak Private Medical Practice, Dworcowa 13/u6a, 85-009 Bydgoszcz, Poland. Die Arbeit wurde bisher 35-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background/Objectives: The aim of this study was to assess the diagnostic accuracy of the AI-driven platform Diagnocat for evaluating endodontic treatment outcomes using cone beam computed tomography (CBCT) images.
Methods
A total of 55 consecutive patients (15 males and 40 females, aged 12–70 years) referred for CBCT imaging were included. CBCT images were analyzed using Diagnocat’s AI platform, which assessed parameters such as the probability of filling, adequate obturation, adequate density, overfilling, voids in filling, short filling, and root canal number. The images were also evaluated by two experienced human readers. Diagnostic accuracy metrics (accuracy, precision, recall, and F1 score) were assessed and compared to the readers’ consensus, which served as the reference standard.
Results
The AI platform demonstrated high diagnostic accuracy for most parameters, with perfect scores for the probability of filling (accuracy, precision, recall, F1 = 100%). Adequate obturation showed moderate performance (accuracy = 84.1%, precision = 66.7%, recall = 92.3%, and F1 = 77.4%). Adequate density (accuracy = 95.5%, precision, recall, and F1 = 97.2%), overfilling (accuracy = 95.5%, precision = 86.7%, recall = 100%, and F1 = 92.9%), and short fillings (accuracy = 95.5%, precision = 100%, recall = 86.7%, and F1 = 92.9%) also exhibited strong performance. The performance of AI for voids in filling detection (accuracy = 88.6%, precision = 88.9%, recall = 66.7%, and F1 = 76.2%) highlighted areas for improvement.
Conclusions
The AI platform Diagnocat showed high diagnostic accuracy in evaluating endodontic treatment outcomes using CBCT images, indicating its potential as a valuable tool in dental radiology.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Kazimierczak Private Medical Practice, Dworcowa 13/u6a, 85-009 Bydgoszcz, Poland.
- Department of Radiology and Diagnostic Imaging, University Hospital No. 1 in Bydgoszcz, Marii Skłodowskiej Curie 9, 85-094 Bydgoszcz, Poland.
- Department of Radiology and Diagnostic Imaging, Collegium Medicum, Nicolaus Copernicus University in Torun, Jagiellońska 13-15, 85-067 Bydgoszcz, Poland.
- Chair of Practical Clinical Dentistry, Department of Diagnostics, Poznań University of Medical Sciences, 61-701 Poznań, Poland.
- Dental Primus, Poznańska 18, 88-100 Inowrocław, Poland.
ORCID-Profile: Wojciech Kazimierczak, Natalia Kazimierczak, Julien Issa, Róża Wajer, Zbigniew Serafin
Zitieren
APA
Kazimierczak, W., Kazimierczak, N., Issa, J., Wajer, R., Wajer, A., Kalka, S., & Serafin, Z. (2024). Endodontic Treatment Outcomes in Cone Beam Computed Tomography Images—Assessment of the Diagnostic Accuracy of AI. Journal of Clinical Medicine, 13(14), 4116. https://doi.org/10.3390/jcm13144116
Vancouver
Kazimierczak W, Kazimierczak N, Issa J, Wajer R, Wajer A, Kalka S, et al. Endodontic Treatment Outcomes in Cone Beam Computed Tomography Images—Assessment of the Diagnostic Accuracy of AI. Journal of Clinical Medicine. 2024;13(14):4116. doi:10.3390/jcm13144116
BibTeX
@article{Kazimierczak2024,
author = {Kazimierczak, Wojciech and Kazimierczak, Natalia and Issa, Julien and Wajer, Róża and Wajer, Adrian and Kalka, Sandra and Serafin, Zbigniew},
title = {Endodontic Treatment Outcomes in Cone Beam Computed Tomography Images—Assessment of the Diagnostic Accuracy of AI},
journal = {Journal of Clinical Medicine},
year = {2024},
volume = {13},
number = {14},
pages = {4116},
doi = {10.3390/jcm13144116}
}
EUVIMED