Robotic Mitral Valve Repair: Impact of Experience on Results and Complex Mitral Disease Treatment
Journal of Clinical Medicine · 26.06.2024 · 13 (13) · 3744
DOI: 10.3390/jcm13133744 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 26.06.2024. Verfasst von Antonio Lio und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiac Surgery and Transplantation, S. Camillo Hospital, Circonvallazione Gianicolense 87, 00152 Rome, Italy. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background/Objectives: Robotically assisted mitral valve (MV) surgery is the least invasive surgical approach to the MV. The aim of the present study is to report our experience with robotically assisted MV repair, trying to define how experience could impact on postoperative results.
Methods
This is a retrospective study on 144 patients who underwent robotic MV repair from November 2011 to March 2023. Patients were divided in two groups: Group 1, including 39 patients (November 2011–January 2013) operated using the Da Vinci Si system, and Group 2, including 105 patients operated (February 2020–March 2023) using the new Da Vinci Xi system.
Results
Mean age was 58 ± 10 years. Increased use of external aortic clamp was observed in Group 2. A significant reduction of surgical times was observed: cardiopulmonary bypass time was 155 ± 44 min in Group 1 and 121 ± 36 min in Group 2 (p = 0.002), whereas cross-clamp time was 112 ± 25 min in Group 1 and 68 ± 39 min in Group 2 (p < 0.001). In-hospital mortality was 0.7%, and 10-year survival was 96 ± 2%. Freedom from reoperation was 100%. A higher percentage of complex and most complex MV repairs were performed in Group 2 (36% in Group 1 vs. 52% in Group 2, p = 0.001).
Conclusions
Robotic-assisted MV repair is associated with excellent results. Experience is a key element to overcome the limitations of this technology. Finally, the robotic platform could improve results in difficult MV repair.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiac Surgery and Transplantation, S. Camillo Hospital, Circonvallazione Gianicolense 87, 00152 Rome, Italy.
ORCID-Profile: Antonio Lio, Ilaria Chirichilli, Francesco Irace
Zitieren
APA
Lio, A., Russo, M., Sangiorgi, B., Nicolò, F., Chirichilli, I., Irace, F., Ranocchi, F., & Musumeci, F. (2024). Robotic Mitral Valve Repair: Impact of Experience on Results and Complex Mitral Disease Treatment. Journal of Clinical Medicine, 13(13), 3744. https://doi.org/10.3390/jcm13133744
Vancouver
Lio A, Russo M, Sangiorgi B, Nicolò F, Chirichilli I, Irace F, et al. Robotic Mitral Valve Repair: Impact of Experience on Results and Complex Mitral Disease Treatment. Journal of Clinical Medicine. 2024;13(13):3744. doi:10.3390/jcm13133744
BibTeX
@article{Lio2024,
author = {Lio, Antonio and Russo, Marco and Sangiorgi, Beatrice and Nicolò, Francesca and Chirichilli, Ilaria and Irace, Francesco and Ranocchi, Federico and Musumeci, Francesco},
title = {Robotic Mitral Valve Repair: Impact of Experience on Results and Complex Mitral Disease Treatment},
journal = {Journal of Clinical Medicine},
year = {2024},
volume = {13},
number = {13},
pages = {3744},
doi = {10.3390/jcm13133744}
}
EUVIMED