EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

No Changes in Keratometry Readings and Anterior Chamber Depth after XEN Gel Implantation in Patients with Glaucoma

Filippo Tatti iD, Claudia Tronci, Filippo Lixi iD, Giuseppe Demarinis iD, Sviatlana Kuzmich, Enrico Peiretti iD, Maurizio Fossarello iD, Giuseppe Giannaccare iD

Journal of Clinical Medicine · 26.04.2024 · 13 (9) · 2537

DOI: 10.3390/jcm13092537 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 26.04.2024. Verfasst von Filippo Tatti und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgical Sciences, Eye Clinic, University of Cagliari, 09124 Cagliari, Italy. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

This study aimed to compare keratometry and anterior chamber depth (ACD) changes after XEN implantation in primary open-angle glaucoma (POAG) cases over a 3-month follow-up period.

Methods

Twenty patients with POAG who underwent XEN63 implantation, either standalone or combined with cataract surgery, were included. Preoperative data, including best-corrected visual acuity (BCVA), refraction, gonioscopy, ophthalmoscopy, intraocular pressure (IOP) evaluation, and axial length, were collected. Corneal topography and ACD measurements were assessed preoperatively and at postoperative days 1, 7, 15, 30, 60, and 90. Each patient’s eye that underwent XEN surgery was included in the study group, with the fellow eye serving as a control.

Results

In the study group, there was a significant decrease in IOP after XEN stent implantation at all investigated time intervals (p < 0.05). However, changes in mean ACD did not show statistically significant differences at any follow-up examination in both the study and control groups. Additionally, keratometry readings revealed no significant changes in total astigmatism or steep keratometry values in either group.

Conclusions

XEN implantation in POAG cases resulted in a significant decrease in IOP over the 3-month follow-up period. However, there were no significant changes observed in mean ACD or keratometry readings, indicating stability in these parameters post-XEN implantation. These findings suggest that XEN implantation may be an effective option for IOP reduction without affecting corneal curvature or ACD in POAG patients.

Schlagwörter

Stichwörter der Autor:innen

XENanterior chamber depthastigmatismglaucoma surgerykeratometry

Autor:innen und Institutionen

  • Department of Surgical Sciences, Eye Clinic, University of Cagliari, 09124 Cagliari, Italy.

ORCID-Profile: Filippo Tatti, Filippo Lixi, Giuseppe Demarinis, Enrico Peiretti, Maurizio Fossarello, Giuseppe Giannaccare

Zitieren

APA

Tatti, F., Tronci, C., Lixi, F., Demarinis, G., Kuzmich, S., Peiretti, E., Fossarello, M., & Giannaccare, G. (2024). No Changes in Keratometry Readings and Anterior Chamber Depth after XEN Gel Implantation in Patients with Glaucoma. Journal of Clinical Medicine, 13(9), 2537. https://doi.org/10.3390/jcm13092537

Vancouver

Tatti F, Tronci C, Lixi F, Demarinis G, Kuzmich S, Peiretti E, et al. No Changes in Keratometry Readings and Anterior Chamber Depth after XEN Gel Implantation in Patients with Glaucoma. Journal of Clinical Medicine. 2024;13(9):2537. doi:10.3390/jcm13092537

BibTeX
@article{Tatti2024,
  author = {Tatti, Filippo and Tronci, Claudia and Lixi, Filippo and Demarinis, Giuseppe and Kuzmich, Sviatlana and Peiretti, Enrico and Fossarello, Maurizio and Giannaccare, Giuseppe},
  title = {No Changes in Keratometry Readings and Anterior Chamber Depth after XEN Gel Implantation in Patients with Glaucoma},
  journal = {Journal of Clinical Medicine},
  year = {2024},
  volume = {13},
  number = {9},
  pages = {2537},
  doi = {10.3390/jcm13092537}
}
Kostenlos starten →