EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Focal Pulsed Field Ablation for Atrial Arrhythmias: Efficacy and Safety under Deep Sedation

Sebastian Weyand iD, Viola Adam, Paloma Biehler, Patricia Hägele, Simon Hanger, David Heinzmann, Stephanie Löbig, Andrei Pinchuk, Christian Waechter, Peter Seizer

Journal of Clinical Medicine · 19.01.2024 · 13 (2) · 576

DOI: 10.3390/jcm13020576 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 19.01.2024. Verfasst von Sebastian Weyand und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Ostalb Clinic Aalen, Im Kaelblesrain 1, 73430 Aalen, Germany. Die Arbeit wurde bisher 25-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Focal pulsed field ablation (PFA) is a novel technique for treating cardiac arrhythmias. It has demonstrated positive results in initial studies and has a good safety profile. In recent studies, PFA was often utilized for first-time pulmonary vein isolation (PVI) and was performed under general anesthesia. In our study, we assessed the feasibility, safety, acute procedural efficacy, and efficiency of focal PFA under deep sedation in patients, 80% of whom had undergone at least one left atrial ablation previously. We treated 30 patients (71 ± 7, 46% male) using the CENTAURI system for various atrial arrhythmias, including atrial fibrillation, typical and atypical atrial flutter, and focal atrial tachycardia. The average procedure and fluoroscopy times were 122 ± 43 min and 9 ± 7 min, respectively. A total of 83.33% of patients received additional line ablations beyond PVI, specifically targeting the posterior box and anterior mitral line. All ablations were successfully performed in deep sedation with only one major and one minor complication observed. The major complication was a vasospasm of the right coronary artery during ablation of the cavotricuspid isthmus, which was treated successfully with intracoronary nitroglycerin. All patients could be discharged in sinus rhythm. Moreover, adenosine appears effective in identifying dormant conduction in some patients after focal PFA. In conclusion, focal PFA is an effective approach for complex left atrial ablations under deep sedation, offering both high efficacy and efficiency with a reliable safety profile. Studies on long-term outcomes are needed.

Schlagwörter

Stichwörter der Autor:innen

CENTAURIadenosine testingatrial fibrillationatypical fluttercoronary vasospasmrepeat ablation

Autor:innen und Institutionen

  • Department of Cardiology, Ostalb Clinic Aalen, Im Kaelblesrain 1, 73430 Aalen, Germany.
  • Department of Cardiology, University Hospital Tuebingen, Otfried-Mueller-Straße 10, 72076 Tuebingen, Germany.
  • Department of Cardiology, University Hospital Marburg, Philipps University Marburg, Baldingerstraße, 35043 Marburg, Germany.

ORCID-Profile: Sebastian Weyand

Zitieren

APA

Weyand, S., Adam, V., Biehler, P., Hägele, P., Hanger, S., Heinzmann, D., Löbig, S., Pinchuk, A., Waechter, C., & Seizer, P. (2024). Focal Pulsed Field Ablation for Atrial Arrhythmias: Efficacy and Safety under Deep Sedation. Journal of Clinical Medicine, 13(2), 576. https://doi.org/10.3390/jcm13020576

Vancouver

Weyand S, Adam V, Biehler P, Hägele P, Hanger S, Heinzmann D, et al. Focal Pulsed Field Ablation for Atrial Arrhythmias: Efficacy and Safety under Deep Sedation. Journal of Clinical Medicine. 2024;13(2):576. doi:10.3390/jcm13020576

BibTeX
@article{Weyand2024,
  author = {Weyand, Sebastian and Adam, Viola and Biehler, Paloma and Hägele, Patricia and Hanger, Simon and Heinzmann, David and Löbig, Stephanie and Pinchuk, Andrei and Waechter, Christian and Seizer, Peter},
  title = {Focal Pulsed Field Ablation for Atrial Arrhythmias: Efficacy and Safety under Deep Sedation},
  journal = {Journal of Clinical Medicine},
  year = {2024},
  volume = {13},
  number = {2},
  pages = {576},
  doi = {10.3390/jcm13020576}
}
Kostenlos starten →