A Review of Intraocular Lens Power Calculation Formulas Based on Artificial Intelligence
Journal of Clinical Medicine · 16.01.2024 · 13 (2) · 498
DOI: 10.3390/jcm13020498 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Journal of Clinical Medicine, online erschienen am 16.01.2024. Verfasst von Wiktor Stopyra und 2 weiteren Autor:innen. Beteiligte Einrichtung: MW-Med Eye Centre, 31-416 Krakow, Poland. Die Arbeit wurde bisher 59-mal zitiert (Crossref) und nennt 61 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
The proper selection of an intraocular lens power calculation formula is an essential aspect of cataract surgery. This study evaluated the accuracy of artificial intelligence-based formulas.
Design
Systematic review.
Methods
This review comprises articles evaluating the exactness of artificial intelligence-based formulas published from 2017 to July 2023. The papers were identified by a literature search of various databases (Pubmed/MEDLINE, Google Scholar, Crossref, Cochrane Library, Web of Science, and SciELO) using the terms “IOL formulas”, “FullMonte”, “Ladas”, “Hill-RBF”, “PEARL-DGS”, “Kane”, “Karmona”, “Hoffer QST”, and “Nallasamy”. In total, 25 peer-reviewed articles in English with the maximum sample and the largest number of compared formulas were examined.
Results
The scores of the mean absolute error and percentage of patients within ±0.5 D and ±1.0 D were used to estimate the exactness of the formulas. In most studies the Kane formula obtained the smallest mean absolute error and the highest percentage of patients within ±0.5 D and ±1.0 D. Second place was typically achieved by the PEARL DGS formula. The limitations of the studies were also discussed.
Conclusions
Kane seems to be the most accurate artificial intelligence-based formula. PEARL DGS also gives very good results. Hoffer QST, Karmona, and Nallasamy are the newest, and need further evaluation.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- MW-Med Eye Centre, 31-416 Krakow, Poland.
- Department of Medicine, University of Applied Sciences, 34-400 Nowy Targ, Poland.
- Great Lakes Eye Care, Saint Joseph, MI 49085, USA.
- Department of Neurology and Ophthalmology, College of Osteopathic Medicine, Michigan State University, East Lansing, MI 48824, USA.
- Institute for Research in Ophthalmology, Foundation for Ophthalmology Development, 61-553 Poznan, Poland.
ORCID-Profile: Wiktor Stopyra, David L Cooke, Andrzej Grzybowski
Zitieren
APA
Stopyra, W., Cooke, D. L., & Grzybowski, A. (2024). A Review of Intraocular Lens Power Calculation Formulas Based on Artificial Intelligence. Journal of Clinical Medicine, 13(2), 498. https://doi.org/10.3390/jcm13020498
Vancouver
Stopyra W, Cooke DL, Grzybowski A. A Review of Intraocular Lens Power Calculation Formulas Based on Artificial Intelligence. Journal of Clinical Medicine. 2024;13(2):498. doi:10.3390/jcm13020498
BibTeX
@article{Stopyra2024,
author = {Stopyra, Wiktor and Cooke, David L and Grzybowski, Andrzej},
title = {A Review of Intraocular Lens Power Calculation Formulas Based on Artificial Intelligence},
journal = {Journal of Clinical Medicine},
year = {2024},
volume = {13},
number = {2},
pages = {498},
doi = {10.3390/jcm13020498}
}
EUVIMED