Exploring the Validity of an Optoelectronic Integrated Cone Beam Computed Tomography Jaw Tracking System
Journal of Clinical Medicine · 20.06.2023 · 12 (12) · 4145
DOI: 10.3390/jcm12124145 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 20.06.2023. Verfasst von Hayo C van der Helm und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthodontics, University Medical Center Groningen, University of Groningen, Hanzeplein 1, 9713 GZ Groningen, The Netherlands. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Jaw motion tracking functionalities of cone beam computed tomography (CBCT)-scanners can visualize, record, and analyze movements of the mandible. In this explorative study, the validity of the 4D-Jaw Motion module (4D-JM) of the ProMax 3D Mid CBCT scanner (Planmeca, Helsinki, Finland) was tested in vitro. The validity of the 4D-JM was accepted if values differed less than 0.6 mm (three voxels sizes) from the gold standard. Three dry human skulls were used. CBCT scans, the gold standard, were taken in eight jaw positions and exported as three-dimensional (3D) models. Individualized 3D-printed dental wafers ensured the correct positioning of the mandible. Jaw positions were recorded with the 4D-JM tracking device and exported as 3D models. The coordinates of six reference points for both superimposed 3D models were obtained. The differences in the x, y and z-axis and the corresponding vector differences between gold standard 3D models and 4D-JM models were calculated. For the mandible 10% and for the maxilla 90% of the vector differences fell within 0.6 mm of the gold standard. With an increasing vertical jaw opening, larger differences between the gold standard and the 4D-JM 3D models were found. The smallest differences of the mandible were observed on the x axis. In this study, the 4D-JM validity was not acceptable by the authors’ predefined standards.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthodontics, University Medical Center Groningen, University of Groningen, Hanzeplein 1, 9713 GZ Groningen, The Netherlands.
- Department of Dentistry and Oral Hygiene, University Medical Center Groningen, University of Groningen, Hanzeplein 1, 9713 GZ Groningen, The Netherlands.
- Department of Rehabilitation, University Medical Center Groningen, University of Groningen, Hanzeplein 1, 9713 GZ Groningen, The Netherlands.
- Department of Oral and Maxillofacial Surgery, University Medical Center Groningen, University of Groningen, Hanzeplein 1, 9713 GZ Groningen, The Netherlands.
- Sirindhorn School of Prosthetics and Orthotics, Faculty of Medicine Siriraj Hospital, Mahidol University, 14 Arun Amarin Rd, Bangkok 10700, Thailand.
- Department of Orthodontics and Dentofacial Orthopedics, School of Dental Medicine, Medical Faculty, University of Bern, Freiburgstrasse 7, CH-3010 Bern, Switzerland.
ORCID-Profile: Arjan J A Dieters, Pieter U Dijkstra, Anne Marie Kuijpers-Jagtman
Zitieren
APA
van der Helm, H. C., Dieters, A. J. A., Dijkstra, P. U., van der Meer, W. J., & Kuijpers-Jagtman, A. M. (2023). Exploring the Validity of an Optoelectronic Integrated Cone Beam Computed Tomography Jaw Tracking System. Journal of Clinical Medicine, 12(12), 4145. https://doi.org/10.3390/jcm12124145
Vancouver
van der Helm HC, Dieters AJA, Dijkstra PU, van der Meer WJ, Kuijpers-Jagtman AM. Exploring the Validity of an Optoelectronic Integrated Cone Beam Computed Tomography Jaw Tracking System. Journal of Clinical Medicine. 2023;12(12):4145. doi:10.3390/jcm12124145
BibTeX
@article{vanderHelm2023,
author = {van der Helm, Hayo C and Dieters, Arjan J A and Dijkstra, Pieter U and van der Meer, Wicher J and Kuijpers-Jagtman, Anne Marie},
title = {Exploring the Validity of an Optoelectronic Integrated Cone Beam Computed Tomography Jaw Tracking System},
journal = {Journal of Clinical Medicine},
year = {2023},
volume = {12},
number = {12},
pages = {4145},
doi = {10.3390/jcm12124145}
}
EUVIMED