Evaluation of Different Contrast Agents for Regional Lung Perfusion Measurement Using Electrical Impedance Tomography: An Experimental Pilot Study
Journal of Clinical Medicine · 07.04.2023 · 12 (8) · 2751
DOI: 10.3390/jcm12082751 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 07.04.2023. Verfasst von Thomas Muders und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology and Intensive Care Medicine, University Hospital Bonn, 53127 Bonn, Germany. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deutsche Forschungsgemeinschaft, German Research Council (Deutsche Forschungsgemeinschaft, DFG), Department of Anesthesiology and Intensive Care Medicine, University Hospital Bonn, Germany.
Abstract (Originalsprache)
Monitoring regional blood flow distribution in the lungs appears to be useful for individually optimizing ventilation therapy. Electrical impedance tomography (EIT) can be used at the bedside for indicator-based regional lung perfusion measurement. Hypertonic saline is widely used as a contrast agent but could be problematic for clinical use due to potential side effects. In five ventilated healthy pigs, we investigated the suitability of five different injectable and clinically approved solutions as contrast agents for EIT-based lung perfusion measurement. Signal extraction success rate, signal strength, and image quality were analyzed after repeated 10 mL bolus injections during temporary apnea. The best results were obtained using NaCl 5.85% and sodium-bicarbonate 8.4% with optimal success rates (100%, each), the highest signal strengths (100 ± 25% and 64 ± 17%), and image qualities (r = 0.98 ± 0.02 and 0.95 ± 0.07). Iomeprol 400 mg/mL (non-ionic iodinated X-ray contrast medium) and Glucose 5% (non-ionic glucose solution) resulted in mostly well usable signals with above average success rates (87% and 89%), acceptable signal strength (32 ± 8% and 16 + 3%), and sufficient image qualities (r = 0.80 ± 0.19 and 0.72 ± 0.21). Isotonic balanced crystalloid solution failed due to a poor success rate (42%), low signal strength (10 ± 4%), and image quality (r = 0.43 ± 0.28). While Iomeprol might enable simultaneous EIT and X-ray measurements, glucose might help to avoid sodium and chloride overload. Further research should address optimal doses to balance reliability and potential side effects.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Anesthesiology and Intensive Care Medicine, University Hospital Bonn, 53127 Bonn, Germany.
- Chair for Medical Information Technology, RWTH Aachen University, 52074 Aachen, Germany.
ORCID-Profile: Thomas Muders, Benjamin Hentze, Steffen Leonhardt
Förderung
- Deutsche Forschungsgemeinschaft
- German Research Council (Deutsche Forschungsgemeinschaft, DFG)
- Department of Anesthesiology and Intensive Care Medicine, University Hospital Bonn, Germany
Zitieren
APA
Muders, T., Hentze, B., Leonhardt, S., & Putensen, C. (2023). Evaluation of Different Contrast Agents for Regional Lung Perfusion Measurement Using Electrical Impedance Tomography: An Experimental Pilot Study. Journal of Clinical Medicine, 12(8), 2751. https://doi.org/10.3390/jcm12082751
Vancouver
Muders T, Hentze B, Leonhardt S, Putensen C. Evaluation of Different Contrast Agents for Regional Lung Perfusion Measurement Using Electrical Impedance Tomography: An Experimental Pilot Study. Journal of Clinical Medicine. 2023;12(8):2751. doi:10.3390/jcm12082751
BibTeX
@article{Muders2023,
author = {Muders, Thomas and Hentze, Benjamin and Leonhardt, Steffen and Putensen, Christian},
title = {Evaluation of Different Contrast Agents for Regional Lung Perfusion Measurement Using Electrical Impedance Tomography: An Experimental Pilot Study},
journal = {Journal of Clinical Medicine},
year = {2023},
volume = {12},
number = {8},
pages = {2751},
doi = {10.3390/jcm12082751}
}
EUVIMED