Mechanical Insufflation-Exsufflation: Considerations for Improving Clinical Practice
Journal of Clinical Medicine · 31.03.2023 · 12 (7) · 2626
DOI: 10.3390/jcm12072626 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Journal of Clinical Medicine, online erschienen am 31.03.2023. Verfasst von Michelle Chatwin und 1 weiteren Autor:innen. Beteiligte Einrichtung: NMCCC, The National Hospital for Neurology and Neurosurgery, University College London Hospitals Foundation Trust, London WC1N 3BG, UK. Die Arbeit wurde bisher 43-mal zitiert (Crossref) und nennt 70 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The provision of mechanical insufflation-exsufflation (MI-E) devices to enhance cough efficacy is increasing. Typically, MI-E devices are used to augment cough in patients with neuromuscular disorders but also in patients who are weak in an acute care setting. Despite a growing evidence base for the use of these devices, there are barriers to the provision of MI-E, including clinician lack of knowledge and confidence. Enhancing clinician education and confidence is key. Individualized or protocolized approaches can be used to initiate MI-E. Evaluation of MI-E efficacy is critical. One method to evaluate effectiveness of MI-E is the MI-E-assisted cough peak flow (CPF). However, this should always be considered alongside other factors discussed in this review. The purpose of this review is to increase the theoretical understanding of the provision and evaluation of MI-E and provide insight into how this knowledge can be applied into clinical practice. Approaches to initiation and titration can be selected based on the clinical situation, patient diagnosis (including and beyond neuromuscular disorders), and clinician’s confidence.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- NMCCC, The National Hospital for Neurology and Neurosurgery, University College London Hospitals Foundation Trust, London WC1N 3BG, UK.
- Clinical and Academic Department of Sleep and Breathing, Royal Brompton Hospital, Part of Guys and St Thomas' NHS Foundation Trust, London SW3 6NP, UK.
- Department of Paediatrics, Royal Brompton Hospital, Part of Guys and St Thomas' NHS Foundation Trust, London SW3 6NP, UK.
Zitieren
APA
Chatwin, M., & Wakeman, R. H. (2023). Mechanical Insufflation-Exsufflation: Considerations for Improving Clinical Practice. Journal of Clinical Medicine, 12(7), 2626. https://doi.org/10.3390/jcm12072626
Vancouver
Chatwin M, Wakeman RH. Mechanical Insufflation-Exsufflation: Considerations for Improving Clinical Practice. Journal of Clinical Medicine. 2023;12(7):2626. doi:10.3390/jcm12072626
BibTeX
@article{Chatwin2023,
author = {Chatwin, Michelle and Wakeman, Ruth Helen},
title = {Mechanical Insufflation-Exsufflation: Considerations for Improving Clinical Practice},
journal = {Journal of Clinical Medicine},
year = {2023},
volume = {12},
number = {7},
pages = {2626},
doi = {10.3390/jcm12072626}
}