EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Temporal Structure in Free-Living Wearable Pulse Rate and Pulse Rate Variability: Beyond Daily and Nightly Averages

Ruixue Cai, Amir Rahmani, Shahab Haghayegh

Journal of Cardiovascular Development and Disease · 13.11.2026 · 13 (11) · 589

DOI: 10.3390/jcdd13110589 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Cardiovascular Development and Disease, online erschienen am 13.11.2026. Verfasst von Ruixue Cai und 2 weiteren Autor:innen. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Institutes of Health.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Wearable pulse metrics are typically reported as a single daily, waking, or nightly average. This presentation of the data may mask differences between sleep and wakefulness, temporal variations within a given state, and differences in the amount of signal retained. To determine whether single-value averages provide a representative summary of free-living pulse physiology, we analyzed 28 days of smartwatch and smart-ring data from 35 participants. Sleep and waking periods were identified using the smart-ring sleep data. Pulse rate was obtained from the smartwatch-generated values, and pulse rate variability (PRV) was calculated from the raw photoplethysmography as the root mean square of successive pulse-interval differences (RMSSD) and standard deviation of pulse-to-pulse intervals (SDNN). Analyses compared paired sleep–wake periods and examined temporal variability within both waking and sleep periods. Mean pulse rate was 72.4 beats/min during sleep and 89.1 beats/min during the subsequent waking period (difference: −16.7 beats/min; 95% confidence interval [CI], −23.0 to −10.2). The mean absolute deviation of the five-minute waking pulse-rate measurements from the waking-period mean was 10.89 beats/min (95% CI, 9.75–12.02); on average, 44.6% of waking measurements differed from the mean by more than 10 beats/min. During sleep, the mean absolute deviation from the period mean was 4.30 beats/min (95% CI, 3.17–5.56). From earlier to later sleep, RMSSD increased by 40.8% (95% CI, 18.7–67.5%; q = 0.0001) and SDNN increased by 82.6% (95% CI, 51.4–117.4%; q = 0.0001). Only 8.6% of the waking recordings met the PRV quality criteria, whereas 64.0% of the sleep recordings did. In summary, single-value averages may not capture differences between sleep and wakefulness or temporal structure within states; unequal signal retention may also affect the representativeness of state averages. Therefore, reports of wearable pulse biomarkers should specify sleep–wake state, within-state timing, aggregation method, and signal retention criteria.

Förderung

  • National Institutes of Health

Zitieren

APA

Cai, R., Rahmani, A., & Haghayegh, S. (2026). Temporal Structure in Free-Living Wearable Pulse Rate and Pulse Rate Variability: Beyond Daily and Nightly Averages. Journal of Cardiovascular Development and Disease, 13(11), 589. https://doi.org/10.3390/jcdd13110589

Vancouver

Cai R, Rahmani A, Haghayegh S. Temporal Structure in Free-Living Wearable Pulse Rate and Pulse Rate Variability: Beyond Daily and Nightly Averages. Journal of Cardiovascular Development and Disease. 2026;13(11):589. doi:10.3390/jcdd13110589

BibTeX
@article{Cai2026,
  author = {Cai, Ruixue and Rahmani, Amir and Haghayegh, Shahab},
  title = {Temporal Structure in Free-Living Wearable Pulse Rate and Pulse Rate Variability: Beyond Daily and Nightly Averages},
  journal = {Journal of Cardiovascular Development and Disease},
  year = {2026},
  volume = {13},
  number = {11},
  pages = {589},
  doi = {10.3390/jcdd13110589}
}
Kostenlos starten →