Spatiotemporal Stability of Persistent Atrial Fibrillation Sources: Stable Source or Disease Progression?
Journal of Cardiovascular Development and Disease · 09.06.2026 · 13 (6) · 256
DOI: 10.3390/jcdd13060256 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Cardiovascular Development and Disease, online erschienen am 09.06.2026. Verfasst von Rita B Gagyi und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Internal Medicine, Cardiology Centre, University of Szeged, Semmelweis Street 8, 6725 Szeged, Hungary. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Aims
To assess the spatiotemporal stability of extra-pulmonary vein (PV) sources in patients with persistent atrial fibrillation (AF). Methods and results: Nine patients (mean age 63 ± 9 years, 55% male) with persistent AF were included who underwent an initial and at least one redo catheter ablation procedure utilizing panoramic atrial mapping (PAM) systems (CardioInsight, electrographic flow (EGF), and/or charge density (CDM) mapping). Procedures were performed in the following combinations: CDM-CDM (1 patient), CDM-EGF (1 patient), EGF-CDM (3 patients), CardioInsight-CDM (1 patient), EGF-EGF (3 patients). We reviewed maps and analyzed the location of AF sources. Spatiotemporal stability was defined as the presence of an AF source of identical location on available maps during the initial and the redo procedure. In 4 patients (44.4%), localization of AF sources mapped at the repeat procedure corresponded with the localization of sources mapped during the index procedure. In two patients, no sources were identified during the second procedure. In the remaining 3 patients, the localization of sources was detected at different locations.
Conclusions
Our findings suggest the presence of spatiotemporal stability of AF sources; however, novel sources can also be found during the repeated procedure, consistent with disease progression.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Internal Medicine, Cardiology Centre, University of Szeged, Semmelweis Street 8, 6725 Szeged, Hungary.
- 5th Department of Internal Medicine, Faculty of Medicine, "Iuliu Hațieganu" University of Medicine and Pharmacy, 400347 Cluj-Napoca, Romania.
- Cortex Inc., Menlo Park, CA 94025, USA.
- Acutus Medical Inc., 1930 Zaventem, Belgium.
ORCID-Profile: Rita B Gagyi, Mate Vamos, Attila Nemes, Tamas Szili-Torok
Zitieren
APA
Gagyi, R. B., Minciuna, I. A., Vamos, M., Nemes, A., Ruppersberg, P., Bories, W., & Szili-Torok, T. (2026). Spatiotemporal Stability of Persistent Atrial Fibrillation Sources: Stable Source or Disease Progression?. Journal of Cardiovascular Development and Disease, 13(6), 256. https://doi.org/10.3390/jcdd13060256
Vancouver
Gagyi RB, Minciuna IA, Vamos M, Nemes A, Ruppersberg P, Bories W, et al. Spatiotemporal Stability of Persistent Atrial Fibrillation Sources: Stable Source or Disease Progression?. Journal of Cardiovascular Development and Disease. 2026;13(6):256. doi:10.3390/jcdd13060256
BibTeX
@article{Gagyi2026,
author = {Gagyi, Rita B and Minciuna, Ioan A and Vamos, Mate and Nemes, Attila and Ruppersberg, Peter and Bories, Wim and Szili-Torok, Tamas},
title = {Spatiotemporal Stability of Persistent Atrial Fibrillation Sources: Stable Source or Disease Progression?},
journal = {Journal of Cardiovascular Development and Disease},
year = {2026},
volume = {13},
number = {6},
pages = {256},
doi = {10.3390/jcdd13060256}
}
EUVIMED