EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Spatiotemporal Stability of Persistent Atrial Fibrillation Sources: Stable Source or Disease Progression?

Rita B Gagyi iD, Ioan A Minciuna, Mate Vamos iD, Attila Nemes iD, Peter Ruppersberg, Wim Bories, Tamas Szili-Torok iD

Journal of Cardiovascular Development and Disease · 09.06.2026 · 13 (6) · 256

DOI: 10.3390/jcdd13060256 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Cardiovascular Development and Disease, online erschienen am 09.06.2026. Verfasst von Rita B Gagyi und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Internal Medicine, Cardiology Centre, University of Szeged, Semmelweis Street 8, 6725 Szeged, Hungary. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

To assess the spatiotemporal stability of extra-pulmonary vein (PV) sources in patients with persistent atrial fibrillation (AF). Methods and results: Nine patients (mean age 63 ± 9 years, 55% male) with persistent AF were included who underwent an initial and at least one redo catheter ablation procedure utilizing panoramic atrial mapping (PAM) systems (CardioInsight, electrographic flow (EGF), and/or charge density (CDM) mapping). Procedures were performed in the following combinations: CDM-CDM (1 patient), CDM-EGF (1 patient), EGF-CDM (3 patients), CardioInsight-CDM (1 patient), EGF-EGF (3 patients). We reviewed maps and analyzed the location of AF sources. Spatiotemporal stability was defined as the presence of an AF source of identical location on available maps during the initial and the redo procedure. In 4 patients (44.4%), localization of AF sources mapped at the repeat procedure corresponded with the localization of sources mapped during the index procedure. In two patients, no sources were identified during the second procedure. In the remaining 3 patients, the localization of sources was detected at different locations.

Conclusions

Our findings suggest the presence of spatiotemporal stability of AF sources; however, novel sources can also be found during the repeated procedure, consistent with disease progression.

Schlagwörter

Stichwörter der Autor:innen

charge densityelectrographic flownon-invasive mappingpanoramic atrial mappingpersistent atrial fibrillation

Autor:innen und Institutionen

  • Department of Internal Medicine, Cardiology Centre, University of Szeged, Semmelweis Street 8, 6725 Szeged, Hungary.
  • 5th Department of Internal Medicine, Faculty of Medicine, "Iuliu Hațieganu" University of Medicine and Pharmacy, 400347 Cluj-Napoca, Romania.
  • Cortex Inc., Menlo Park, CA 94025, USA.
  • Acutus Medical Inc., 1930 Zaventem, Belgium.

ORCID-Profile: Rita B Gagyi, Mate Vamos, Attila Nemes, Tamas Szili-Torok

Zitieren

APA

Gagyi, R. B., Minciuna, I. A., Vamos, M., Nemes, A., Ruppersberg, P., Bories, W., & Szili-Torok, T. (2026). Spatiotemporal Stability of Persistent Atrial Fibrillation Sources: Stable Source or Disease Progression?. Journal of Cardiovascular Development and Disease, 13(6), 256. https://doi.org/10.3390/jcdd13060256

Vancouver

Gagyi RB, Minciuna IA, Vamos M, Nemes A, Ruppersberg P, Bories W, et al. Spatiotemporal Stability of Persistent Atrial Fibrillation Sources: Stable Source or Disease Progression?. Journal of Cardiovascular Development and Disease. 2026;13(6):256. doi:10.3390/jcdd13060256

BibTeX
@article{Gagyi2026,
  author = {Gagyi, Rita B and Minciuna, Ioan A and Vamos, Mate and Nemes, Attila and Ruppersberg, Peter and Bories, Wim and Szili-Torok, Tamas},
  title = {Spatiotemporal Stability of Persistent Atrial Fibrillation Sources: Stable Source or Disease Progression?},
  journal = {Journal of Cardiovascular Development and Disease},
  year = {2026},
  volume = {13},
  number = {6},
  pages = {256},
  doi = {10.3390/jcdd13060256}
}