EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Effect of Pulsed Field Ablation System and Post-Ablation Mapping on Atrial Fibrillation Recurrence

Benjamin J Behers iD, Christoph A Stephenson-Moe, Sammy Shihadeh, Tonya S King iD, Omar Hozayen, Joseph Hozayen, Maria Moreno, Karen M Hamad iD, Antonio Moretta

Journal of Cardiovascular Development and Disease · 02.06.2026 · 13 (6) · 243

DOI: 10.3390/jcdd13060243 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Cardiovascular Development and Disease, online erschienen am 02.06.2026. Verfasst von Benjamin J Behers und 8 weiteren Autor:innen. Beteiligte Einrichtung: Florida State University Internal Medicine Residency at Sarasota Memorial Hospital, Sarasota, FL 34239, USA. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Atrial fibrillation (AF) is the most common arrhythmia worldwide and is associated with significant morbidity and mortality. Catheter ablation of AF has been shown to result in a significant reduction in AF burden and recurrence. Pulsed field ablation (PFA) is a new modality of catheter ablation that is noninferior to its thermal ablation counterparts, coupled with a more favorable safety profile. This study seeks to compare clinical outcomes between two PFA systems: PulseSelect™ (Medtronic, Minneapolis, MN, USA) (circular catheter) and FARAPULSE™ (Boston Scientific, Marlborough, MA, USA) (pentaspline catheter). Secondary aims are to evaluate the impacts of post-ablation mapping with a high-density mapping catheter (PAHDMC) and both procedure and fluoroscopy times on recurrence. Overall, across 895 patients with a median follow-up of 12.5 months, there was a recurrence rate of 39%. PFA system, PAHDMC, and procedure time all had no effect on recurrence. To our knowledge, this is the first study to compare recurrence rates between different PFA systems. Fluoroscopy time, however, was a significant predictor of recurrence. In the pentaspline catheter group, the odds of recurrence were 60% greater for every 15 min increase in fluoroscopy time. Future studies are needed to continue comparing outcomes amongst PFA systems and assess whether PAHDMC improves outcomes in PFAs.

Schlagwörter

Stichwörter der Autor:innen

atrial fibrillationcircular catheterpentaspline catheterpulsed field ablation

Autor:innen und Institutionen

  • Florida State University Internal Medicine Residency at Sarasota Memorial Hospital, Sarasota, FL 34239, USA.
  • Department of Clinical Sciences, Florida State University College of Medicine, Tallahassee, FL 32304, USA.
  • Kolschowsky Research & Education Institute, Sarasota Memorial Health Care System, Sarasota, FL 34239, USA.
  • Sarasota Memorial Hospital, Sarasota, FL 34239, USA.

ORCID-Profile: Benjamin J Behers, Tonya S King, Karen M Hamad

Zitieren

APA

Behers, B. J., Stephenson-Moe, C. A., Shihadeh, S., King, T. S., Hozayen, O., Hozayen, J., Moreno, M., Hamad, K. M., & Moretta, A. (2026). Effect of Pulsed Field Ablation System and Post-Ablation Mapping on Atrial Fibrillation Recurrence. Journal of Cardiovascular Development and Disease, 13(6), 243. https://doi.org/10.3390/jcdd13060243

Vancouver

Behers BJ, Stephenson-Moe CA, Shihadeh S, King TS, Hozayen O, Hozayen J, et al. Effect of Pulsed Field Ablation System and Post-Ablation Mapping on Atrial Fibrillation Recurrence. Journal of Cardiovascular Development and Disease. 2026;13(6):243. doi:10.3390/jcdd13060243

BibTeX
@article{Behers2026,
  author = {Behers, Benjamin J and Stephenson-Moe, Christoph A and Shihadeh, Sammy and King, Tonya S and Hozayen, Omar and Hozayen, Joseph and Moreno, Maria and Hamad, Karen M and Moretta, Antonio},
  title = {Effect of Pulsed Field Ablation System and Post-Ablation Mapping on Atrial Fibrillation Recurrence},
  journal = {Journal of Cardiovascular Development and Disease},
  year = {2026},
  volume = {13},
  number = {6},
  pages = {243},
  doi = {10.3390/jcdd13060243}
}
Kostenlos starten →